EEWORLDEEWORLDEEWORLD

Part Number

Search

FN3482-600-99-E0FXJXX

Description
Three Phase EMI Filter, 480V, 60HzHz,
CategoryAnalog mixed-signal IC    filter   
File Size1MB,5 Pages
ManufacturerSchaffner
Environmental Compliance
Download Datasheet Parametric View All

FN3482-600-99-E0FXJXX Overview

Three Phase EMI Filter, 480V, 60HzHz,

FN3482-600-99-E0FXJXX Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Reach Compliance Codecompliant
Other featuresDERATED OPERATING TEMP 45 TO 70 ALSO AVAILABLE
CertificationUL; EN; IEC
filter typeTHREE PHASE EMI FILTER
high1320 mm
length680 mm
Installation typePANEL MOUNT
working frequency60Hz Hz
Maximum operating temperature45 °C
Minimum operating temperature-25 °C
Rated voltage480 V
width557 mm
DATASHEET
Ecosine Max (5% THID) FN 3482
Ecosine Max, 60 Hz Passive Harmonic Filters
Demonstrate best cost-performance ratio
Achieve 5% THDi for diode rectifier without
DC-link choke and thyristor rectifier
Best-in-class partial load performance
Most compact open panel design for cabinet
integration
Reliable and robust
Plug and play, ready to use
Approvals
UL pending
Features and benefits
Schaffner ecosine harmonic filters represent an
economical solution to the challenge of load-applied
harmonics mitigation in three-phase power systems.
With a plug-and-play approach and more compact
dimensions than comparable products, they can be
quickly installed and easily commissioned. They
increase the reliability and service life of electric
installations, help utilize electric sytem capacity
better, and are the key to meet Power Quality
standards such as IEEE 519. Ecosine filters reshape
your distorted current back to the desired sinusoidal
waveform. Schaffner ecosine filters can be applied to
virtually any kind of power electronics with front-end
six-pulse rectifiers, 3-phase diode or thyristor bridges,
where harmonic current distortion needs to be
reduced to defined limits.
Technical specifications
Nominal operating voltage
Operating frequency
Nominal motor drive input power rating
Total harmonic current distortion THID*
Efficiency
High potential test voltage
Protection category
Cooling
Overload capability
Ambient temperature range
3 x 440 VAC to 480 VAC ±10%
60 Hz ±1 Hz
350 to 600 HP
<5% @ rated power for drives without Ldc
~3.5% @ rated power for drives equipped with 4% Ldc
>99% for rated voltage and power
P -> E 2520 VAC (1s)
IP 00
External cooling**
1.6x rated current for 1 minute, once per hour
–25°C to +45°C fully operational
+45°C to +70°C derated operation***
–25°C to +85°C transport and storage
UL 94 V-2
Filter: UL 61800-5-1, EN 61800-5-1
Chokes: EN 60076-6
TN, TT, IT
>200,000 hours
OV III (IEC 60664-1)
Typical applications
Equipment with front-end six-pulse rectifier
Motor drives
Factory automation equipment
Water/wastewater treatment facilities
Fan and pump applications
HVAC installations
Mission-critical processes
DC fast chargers
Flammability corresponding to
Design corresponding to
Earthing System
MTBF @ 45°C/415 V (Mil-HB-217F)
Overvoltage category
***
*System
requirements: THVD <2%, line voltage unbalance <1%
****
Note: performance specifications in this brochure refer to six-pulse diode rectifiers.
****
SCR rectifier front-ends will produce different results, dependent upon the firing angle of the thyristors.
***
*Please
check the inlet air flow required for cooling table on page 6 of this document.
**** I
derated
= I
nominal
*√((T
max-
T
amb
)/(T
max-
T
nominal
)) = I
nom
*√((70°C-T
amb
)/25°C)
Typical electrical schematic

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2907  1913  1783  1808  2750  59  39  36  37  56 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号