Description
Rocker Switch, On-on, 10A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size333KB,8 Pages
ManufacturerAPEM
Download Datasheet Parametric View All

2636LPCB22000L220V/6 Overview

Rocker Switch, On-on, 10A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount

2636LPCB22000L220V/6 Parametric

Parameter NameAttribute value
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator colorBLACK
Actuator length0.394 inch
Actuator materialPOLYAMIDE
Actuator typeROCKER
body width24.9936 mm
body height16.9926 mm
Body length or diameter32.004 mm
center contact materialCOPPER
Center contact platingSILVER
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@24VDC
Contact functionON-ON
Contact resistance0.01 mΩ
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)24 V
Dielectric withstand voltage2500VRMS V
Electrical life10000 Cycle(s)
End contact materialCOPPER
End contact platingSILVER
Shell materialPOLYAMIDE
illuminationLAMP
Insulation resistance1000000000 Ω
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature55 °C
Minimum operating temperature-10 °C
surface mountNO
Switch typeROCKER SWITCH
Terminal length0.437 inch
Termination typeSCREW
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
Looking for a debugging tool under wince, like windbg
As the title says, it would be best if there is a mature tutorial or document. If there is a way to let windbg debug wince program, I would be grateful for your advice....
shenchen02 Embedded System
C-band monopulse radar frequency source
Starting from the basic requirements of modern radar for frequency source, this paper introduces the engineering scheme of excitation source and coherent local oscillator of single pulse precision mea...
JasonYoo Power technology
Repost: Elevators 60 years later, the motherland tells you to save energy! !
[i=s]This post was last edited by paulhyde on 2014-9-15 09:11[/i] If you were asked to design the elevator of the future, what would you start with? Cool appearance, creative structure, extraordinary ...
大骞骞 Energy Infrastructure?
【Silicon Labs Development Kit Review】+ GPIO Features
The four groups of pins A, B, C, and D of EFM32PG22 can be assigned to any peripheral, such as any signal of GPIO, I2C, SPI, and UART through DBUS Port Mappers. This is very flexible, which means that...
dql2016 Development Kits Review Area
Altera Registration Issues
Why do I register an account on the Altera China official website, but it always says "Your session has expired. Please log in again"?...
火箭_1991 FPGA/CPLD
We are looking for RF R&D engineers to engage in infrared, RF intelligent remote control series, control systems and other products
Recruiting RF R&D Engineer Our company is recruiting a RF R&D engineer. Mainly engaged in infrared, RF intelligent remote control series, control systems and other products. Job requirements: Proficie...
actionq RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2616  2082  668  2617  1867  53  42  14  38  52 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号