EEWORLDEEWORLDEEWORLD

Part Number

Search

2639LHA7/12300L110V1

Description
Rocker Switch, On-off-on, 8A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size333KB,8 Pages
ManufacturerAPEM
Download Datasheet Parametric View All

2639LHA7/12300L110V1 Overview

Rocker Switch, On-off-on, 8A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount

2639LHA7/12300L110V1 Parametric

Parameter NameAttribute value
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator colorGREEN
Actuator length0.354 inch
Actuator materialPOLYAMIDE
Actuator typeROCKER
Other features110VAC FLUORESCENT LAMP
body width24.9936 mm
body height16.9926 mm
Body length or diameter32.004 mm
center contact materialSILVER
Maximum contact current (DC)8 A
Contact (DC) maximum rated R load8A@24VDC
Contact functionON-OFF-ON
Contact resistance0.01 mΩ
Maximum contact voltage (DC)24 V
Dielectric withstand voltage2500VRMS V
Electrical life10000 Cycle(s)
End contact materialSILVER
Shell materialPOLYAMIDE
Insulation resistance1000000000 Ω
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature85 °C
Minimum operating temperature-20 °C
surface mountNO
Switch typeROCKER SWITCH
Terminal length0.437 inch
Termination typeSCREW
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
Please input the capture test cycle and display the code through the serial port
The best is AVR series microcontroller, of course Atmega128 is better. The input waveform is 50Hz square wave. The frequency and period are obtained through T/C1 interrupt capture and displayed by the...
无敌小青年 Microchip MCU
[Transfer] Design of high-efficiency power supply
[p=15, null, left][color=rgb(0, 0, 0)][font=Arial, Helvetica, sans-serif][size=12px]Efficiency is a key parameter in power supply design. Pressure from all sides forces designers of new power supplies...
dontium ADI Reference Circuit
Why are CE debug zones always greyed out and unavailable?
Hello everyone! When I develop with VS.net2005+wince6, why can't CE debug zones be used? It is always grayed out. How can I activate it to make it available? Thank you!...
katrina Embedded System
Help: Communication problem between PXA270 and power chip 1586B!
I am debugging a PXA270 board. The power chip is MAX1586B. I communicate with 1586B through the I2C bus of the PXA270 power management module. Now I want to increase the main frequency of PXA270. I ch...
aideyuyan Embedded System
Ask for some questions about MTD2009J
I am currently working on using MTD2009J to drive stepper motors. I would like to ask the experts to give me some advice on the motor subdivision algorithm. It would be even better if you can provide ...
sands MCU
Guangzhou Ruizhen Electronics! Building a team! Sincerely seeking a chief engineer for long-term and stable cooperation!
[b]Hello everyone! My last name is Liu! Our company is located in Guangzhou. It is a very small company for the time being, but we have ideals and goals. We hope to make a name for ourselves and have ...
rickliu888 Recruitment

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2830  2622  1741  1833  942  57  53  36  37  19 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号