EEWORLDEEWORLDEEWORLD

Part Number

Search

LCS011T19WC22EY

Description
SNAP ACTING/LIMIT SWITCH, SPST, MOMENTARY, 9.95mm, PANEL MOUNT, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size208KB,4 Pages
ManufacturerC&K Components
Environmental Compliance  
Download Datasheet Parametric View All

LCS011T19WC22EY Overview

SNAP ACTING/LIMIT SWITCH, SPST, MOMENTARY, 9.95mm, PANEL MOUNT, ROHS COMPLIANT

LCS011T19WC22EY Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator stroke9.95 mm
Actuator typeLEVER
body width6.4 mm
body height9.8 mm
Body length or diameter19.8 mm
Contact (AC) maximum rated R load.1A@250VAC
Maximum contact current (AC)0.1 A
Maximum contact voltage (AC)250 V
Electrical life10000 Cycle(s)
Manufacturer's serial numberLCS
Installation featuresPANEL MOUNT
Maximum operating force1.47 N
Maximum operating temperature120 °C
Minimum operating temperature
Maximum pre-travel8 mm
sealIP67
surface mountNO
Switch actionMOMENTARY
switch functionSPST
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeWIRE
LCS Series
Subminiature Sealed Snap-acting Switches
Features/Benefits
Compact design
Long life and high electrical capacity
Quick connect, solder terminals,
PC terminals, wire leads
Wide variety of actuator styles
RoHS compatible, RoHS compliant
IP67
Specifications
CONTACT RATING: 6 AMP, 250 V AC and
5 AMP, 125/250 V AC
0.1 AMP, 125/250 V AC
ELECTRICAL LIFE: 10,000 cycles
INSULATION RESISTANCE: 100 M ohm min.
DIELECTRIC STRENGTH: 1,000 VAC
OPERATING TEMPERATURE:
0ºC to +120ºC (without wire)
0ºC to +85ºC (with UL1007 wire)
0ºC to +105ºC (with UL1015 wire)
0ºC to +105ºC (with UL1430 wire)
0ºC to +80ºC (with UL1061 wire)
0ºC to +120ºC (with UL1330 wire)
OPERATING FORCE: (see ACTUATOR’S option sections).
MOUNTING: 2-56 screws, torque 2.3 in/lbs max.
NOTE:
Specifications and materials listed above are for switches with standard options.
For information on specific and custom switches, consult Customer Service center.
14
Typical Applications
Motorized equipment
Sump pump
Thermostatic controls
Computers
Air conditioners
14
Models Available
Materials
SWITCH HOUSING: Thermoplastic polyester or high temperature
thermoplastic (PTS) (UL 94V-0).
ACTUATOR BUTTON: Thermoplastic polyester.
SPRING: Copper alloy.
PIVOT: Copper alloy.
MOVABLE CONTACTS: Silver nickel
STATIONARY CONTACTS: Silver nickel on copper alloy.
TERMINALS: Copper alloy.
ACTUATOR LEVEL: Stainless steel.
J
Snap-acting
Build-A-Switch
To order, simply select desired option from each category and place in the appropriate box. Available options are shown and
described on pages J-27 thru J-29. For additional options not shown in catalog, consult Customer Service Center.
L
Series
LCS
Contact Rating
05
5 AMP, 125/250 V AC
6 AMP, 250 V AC
01
0.1 AMP, 125/250 V AC
C
S
14
Operating Force
1
150 grams
2
203 grams
Actuator
P00
Pin plunger
T00
11.9 mm short lever
T05
17.4 mm short lever
T07
19.4 mm short lever
T13
25.5 mm lever
T19
33.3 mm lever
T28
40.7 mm lever
T43
55.9 mm lever
S26
18.6 mm simulated lever
A05
17.2 mm lever roller
Circuitry
C
SPDT
W
SPST N.C.
Y
SPST N.O.
Wire Type AWG
20
20 AWG
22
22 AWG
24
24 AWG
26
26 AWG
28
28 AWG
30
30 AWG
Wire UL #
(when required)
A
UL1007
B
UL1015
C
UL1430
D
UL1061
E
UL1330
Terminations
S
Solder
Q
0.110 Quick Connect
P
PC Thru Hole
W
Wire leads potted
Z
Wire leads non-potted
Wire Side (when required)
A
Wire out the bottom
B
Wire out the right side
C
Wire out the left side
D
None
Dimensions are shown: mm
Specifications and dimensions subject to change
J–26
www.ck-components.com
TI Pure Digital Audio Amplifier TDAA System
TI Pure Digital Audio Amplifier TDAA System [size=4][b][/b][/size]...
qwqwqw2088 Analogue and Mixed Signal
The sadness and helplessness of a female programmer
The sadness and helplessness of a female programmer. To be honest, I am really tired. I work hard and hard, struggle with men, stay up late and work overtime until the early morning, and am exhausted ...
tiankai001 Talking
Startup Code
Can anyone explain what this code means?IF :DEF:__MICROLIBEXPORT __initial_spEXPORT __heap_baseEXPORT __heap_limitELSEIMPORT __use_two_region_memoryEXPORT __user_initial_stackheap__user_initial_stackh...
xinbako stm32/stm8
Understanding of FPGA DCM clock management unit
Looking at the Xilinx Datasheet, you will notice that Xilinx FPGAs do not have PLLs. In fact, DCM is a time management unit. ----------------------------------------------------- [b]DCM Overview[/b] D...
sadlife1000 FPGA/CPLD
TI Electronic Design Contest --- TI Component Comparison Table for Electronic Contest
TI Electronic Design Contest --- TI Component Comparison Table for Electronic Contest[[i] This post was last edited by qwqwqw2088 on 2013-7-11 23:13 [/i]]...
qwqwqw2088 Analogue and Mixed Signal
ADC0 and ADC1 sample signals separately, how to write interrupts? [LM3S]
Should the base addresses of ADC be ADC0_BASE andADC1_BASE respectively, or should they be unified asADC_BASE? Also, should interrupts be written for both modules or just one? I'm a little dizzy after...
喜鹊王子 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2668  1751  2568  2124  1064  54  36  52  43  22 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号