MCC
Features
•
•
•
•
•
omponents
21201 Itasca Street Chatsworth
!"#
$
% !"#
1N4933GP
THRU
1N4937GP
1 Amp Glass
Passivated Fast
Recovery Rectifier
50 - 600 Volts
DO-41
Glass Passivated Junction
Low Leakage Current
Metalurgically Bonded Construction
Low Cost
Fast Switching
•
•
•
Maximum Ratings
Operating Temperature: -55°C to +150°C
Storage Temperature: -55°C to +150°C
Maximum Thermal Resistance; 30
°C/W
Junction To Lead
MCC
Catalog
Number
Device
Marking
Maximum
Recurrent
Peak
Reverse
Voltage
50V
100V
200V
400V
600V
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
50V
100V
200V
400V
600V
D
1N4933
1N4934
1N4935
1N4936
1N4937
---
---
---
---
---
35V
70V
140V
280V
420V
A
Cathode
Mark
B
D
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
Peak Forward Surge
Current
Maximum
Instantaneous
Forward Voltage
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
Maximum Reverse
Recovery Time
Typical Junction
Capacitance
I
F(AV)
I
FSM
1.0A
30A
T
A
=55°C
C
8.3ms, half sine
V
F
1.3V
I
FM
= 1.0A;
T
J
= 25°C*
T
J
= 25°C
T
J
= 125°C
I
F
=0.5A,
I
R
=1.0A,
I
rr
=0.25A
Measured at
I
F
=1.0A
V
R
=30V
DIMENSIONS
INCHES
MIN
.166
.080
.028
1.000
MM
MIN
4.10
2.00
.70
25.40
I
R
5.0µA
100µA
200ns
T
rr
C
J
DIM
A
B
C
D
MAX
.205
.107
.034
---
MAX
5.20
2.70
.90
---
NOTE
15pF
*Pulse test: Pulse width 300
µsec,
Duty cycle 1%
www.mccsemi.com
1N4933GP thru 1N4937GP
Figure 1
Typical Forward Characteristics
20
10
6
4
1.0
2
Amps
1
.6
.4
.2
25°C
.1
.06
.04
.02
.01
.4
.6
.8
Volts
Instantaneous Forward Current - Amperes
versus
Instantaneous Forward Voltage - Volts
1.0
1.2
1.4
0
.2
Amps
.4
.8
1.2
MCC
Figure 2
Forward Derating Curve
.6
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
50
75
100
°C
Average Forward Rectified Current - Amperes
versus
Ambient Temperature -
°C
125
150
175
Figure 3
Junction Capacitance
100
60
40
20
pF
10
6
4
2
1
.1
.2
.4
1
Volts
2
4
10
20
40
100
200
400
1000
T
J
=25°C
Junction Capacitance - pF
versus
Reverse Voltage - Volts
www.mccsemi.com
1N4933GP thru 1N4937GP
Figure 4
Typical Reverse Characteristics
100
60
40
20
10
6
4 T =100°C
A
2
µAmps
1
.6
.4
.2
.1
.06
.04
.02
.01
20
40
60
80
Volts
Instantaneous Reverse Leakage Current - MicroAmperes
versus
Percent Of Rated Peak Reverse Voltage - Volts
Figure 6
Reverse Recovery Time Characteristic And Test Circuit Diagram
100
120
140
T
A
=25°C
Amps
60
50
40
30
20
10
5
0
MCC
Figure 5
Peak Forward Surge Current
1
2
4
6
8 10
Cycles
20
40
60 80 100
Peak Forward Surge Current - Amperes
versus
Number Of Cycles At 60Hz - Cycles
www.mccsemi.com