EEWORLDEEWORLDEEWORLD

Part Number

Search

PS2T60R1KRN6BU

Description
Analog Circuit
CategoryAnalog mixed-signal IC    The signal circuit   
File Size80KB,4 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

PS2T60R1KRN6BU Overview

Analog Circuit

PS2T60R1KRN6BU Parametric

Parameter NameAttribute value
package instruction,
Reach Compliance Codeunknown
Bussmann
®
Bussmann Power Module Switch
All-In-One Module
Power Module Switch
Rating (Amps)
30
60
100
200
400
PS
Power Module Switch Catalog No.
PS3
PS6
PS1
PS2
PS4
Standard Shunt Trip Ratings
Amp
Rating
30-100
200
400
Voltage
120V, 60HZ
Max
Inrush
4 amps
Max
5
Ontime
1.5 cycles
Momentary
Inrush
140VA
Optional Accessories
Voltage
Rating
Option 1
Control Power Transformer
(CPT) Std. 100VA
5
with PRI &
SEC Fuse (120V Secondary)
208V
240V
480V
600V
24 Vdc Coil
120 Vac Coil
120V
Red
Green
White
30-60A
100A
200A
400A
1 NO & 1 NC
2 NO & 2 NC
Catalog
Number
T20
T24
T48
T60
R2
R1
K
R
G
W
N6
N1
N2
N4
A
B
Bussmann Power Module Switch
Standard Features:
• 30-400 amp 600 Vac 3p Fused Power Switch
• 200,000 amp RMS interrupting
• Shunt trip 120V
• Control power terminal block
• Ground lug per NEC
• Class J fuse mounting only
1
Optional Features:
• Control power transformer with fuses and blocks
• Fire safety interface relay
• Key to test switch
• Pilot light – “ON”
• Isolated neutral lug
2
• Mechanical interlock auxiliary contact for hydraulic
elevators with automatic recall (5 amp 120 Vac rated)
• NEMA 3R, 4, and 12 enclosures available
3
• Phase failure and undervoltage relay available, consult
factory
• For added safety, use the Bussmann SAMI fuse covers to
improve maintenance personnel protection
4
(OSHA 1910.333, paragraph C)
Agency Approvals:
U.L. 98 Enclosed and Dead Front Switch
Guide 96NK3917, File E182262
NEMA 1, U.L. 50, listed enclosure
U.L.c per Canadian Standards C22.2, No. 0-M91-CAN/CSA
C22.2, No. 4-M89 Enclosed Switch
Option 2
Fire Safety Interface
Relay (3PDT, 10 amp, 120V)
Option 3
Key to Test Switch
Option 4
Pilot Light – “ON”
Option 5
Isolated Neutral Lug
(Full Capacity)
2
Option 6
Mechanical interlock auxiliary contact
for hydraulic elevators with automatic
recall (5 amp 120 Vac rated)
Option 7
Optional Enclosure
NEMA 3R
NEMA 4
NEMA 12
U
Y
Z
1
Class
J fuses not included.
200% rated neutral option available where required by excessive
non-linear loads.
3
Through 200A.
4
Through 100A.
5
Will handle up to 447VA inrush.
2
Oversized
Catalog No. Construction:
Catalog number of PS Switch
Options as required in option order as listed above
(i.e. option 1, 2, 3, etc.)
Example: •
100A S.T. Switch 480V-3P – PS1
480–120V CPT – T48
120 Vac Coil Fire Safety Interface Relay – R1
Pilot Light - “ON” (Green) – G
Mech. Interlock (1 NO & 1 NC) – A
Catalog Number PS1T48R1GA
Typical construction includes control power transformer and
fire safety interface relay as minimum options required.
12-28-98
SB98107
Rev. A
Form No. PS
Page 1 of 4
BIF Doc# 1145
Independent buttons affect the digital tube display
Hello everyone, I am a junior who has just learned 51. Recently, I have made something similar to a competition stopwatch. Now I have encountered some problems and would like to ask for help. Use time...
云杰 51mcu
The boot0 pull-down voltage of STM32F103VCT6 is 1.0v
Using a 4.7k resistor to pull down boot0, the voltage measured by a multimeter is 1.0v, and boot1 is also pulled down by 4.7k, the voltage is 0V.Replacing boot0's 4.7k with 1k has basically no change ...
fuqiang stm32/stm8
[Project Discussion] [FPGA Learning Series—How to Configure the Program]
I am a beginner. For beginners, I will briefly talk about the three points about FPGA program configuration that we are most concerned about and must understand. 1. Where is the FPGA program stored? L...
ltbytyn FPGA/CPLD
When the 5V 2A charger is designed, the current drops when in CV mode
Why does the current keep dropping when the charger is in CV mode? It is designed with synchronous rectification. Can anyone help me?...
王智体 Power technology
How to set the WinCE system to execute corresponding actions when there is no operation within a certain period of time?
How to set the system to perform corresponding actions when there is no operation for a certain period of time? My system includes buttons and touch screen. I searched for a similar question on the In...
烽火寒轩 Embedded System
LSM6DS3 calibration issue
Hello everyone, I'm new here!! I have a question for everyone. About the calibration problem of LSM6DS3! ! For example, adxl343 only needs to set the offset register, but LSM6DS3 does not work even if...
陈晓段 MEMS sensors

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1288  2457  1112  2667  405  26  50  23  54  9 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号