ADC200 SERIES
1W, High Isolation SIP, Single & Dual Output DC/DC Converters
Selection Guide
Model
Number
ADC201
ADC202
ADC203
ADC204
ADC205
ADC206
ADC207
ADC208
ADC209
ADC211
ADC212
ADC213
ADC214
ADC215
ADC216
ADC217
ADC218
ADC219
ADC221
ADC222
ADC223
ADC224
ADC225
ADC226
ADC227
ADC228
ADC229
Input
Voltage
VDC
Output
Voltage
VDC
3.3
5
9
12
15
±
5
±
9
±
12
±
15
3.3
5
9
12
15
±
5
±
9
±
12
±
15
3.3
5
9
12
15
±
5
±
9
±
12
±15
Output
Current
mA
260
200
110
84
67
±100
±56
±42
±34
260
200
110
84
67
±100
±56
±42
±34
260
200
110
84
67
±100
±56
±42
±34
Efficiency
% Typ.
73
71
76
78
78
72
77
78
79
74
73
78
80
80
74
79
81
81
73
71
76
78
79
72
76
79
80
Load
Regulation
% Max.
10
10
8
7
7
10
8
7
7
8
8
5
5
5
8
5
5
5
8
8
5
5
5
8
5
5
5
5
(4.5 – 5.5)
Key Features
•
•
•
•
•
•
•
•
•
•
Efficiency up to 81%
3000VDC Isolation
MTBF > 2,000,000 Hours
Low Cost
Input 5, 12 and 24VDC
Output 3.3, 5, 9, 12, 15,
±5, ±9, ±12 and ±15VDC
Temperature Performance
-40°C to +85°C
UL 94V-0 Package Material
Internal SMD Construction
Industry Standard Pinout
12
(10.8 – 13.2)
24
(21.6 – 26.4)
The series consists of 27 models
with input voltages of 5V, 12V and
24VDC which offers standard output
voltages of 3.3V, 5V, 9V, 12V, 15V,
±5V, ±9V, ±12V and ±15VDC for a
wide choice.
The ADC200 series is an excellent
selection for a variety of applications
including distributed power
systems, mixed analog/digital
subsystems, portable test
equipments, local power networks
and battery backed systems.
2463 208th Street, Ste. 205
Torrance, CA 90501
10.2 [0.40]
MPS Industries ADC200 1W
DC/DC's are specially designed
to provide high levels of isolation
3000VDC in a miniature SIP
package.
Mechanical Dimensions
19.5 [0.77]
Pin Connections
Pin
Singles
Duals
0.5 [0.02]
1
2
5
6
7
+Vin
-Vin
-Vout
No Pin
+Vout
+Vin
-Vin
-Vout
Common
+Vout
2.1 [0.08]
18.5 [0.73]
2.54 [0.100]
1
2
5
6
7
0.25 [0.010]
0.50 [0.020]
1.3 [0.05]
Case Size –
5V & 12V Input – 19.5x6.1x10.2mm
(0.77x0.24x0.40inch)
24V Input –19.5x7.1x10.2mm
(0.77x0.28x0.40inch)
Case Material –
Non-Conductive Black Plastic
Weight –
5V & 12V Input – 2.2g (0.08Oz)
24V Input– 2.6g (0.09Oz)
Tolerance
Millimeters
X.X±0.25
X.XX±0.13
±0.05
Inches
X.XX±0.01
X.XXX±0.005
±0.002
T= 6.1 (0.24) for 5V & 12V Input Models
T= 7.1 (0.28) for 24V Input Models
Pin
T
3.2 [0.13]
Tel: (310) 533-1455
Fax: (310) 533-1853
http://www.mpsind.com
E-mail: sales@mpsind.com
ADC200 SERIES
1W, High Isolation SIP, Single & Dual Output DC/DC Converters
Absolute Maximum Ratings
Parameter
5VDC Input Models
Input Surge Voltage
12VDC Input Models
(1000mS)
24VDC Input Models
Lead Temperature
(1.5mm from case for 10sec.)
Internal Power Dissipation
General Characteristics
Min.
-0.7
-0.7
-0.7
---
---
Max. Units
9
18
30
260
450
VDC
VDC
VDC
°C
mW
Parameter
Isolation
Voltage
Isolation
Resistance
Isolation
Capacitance
Switching
Frequency
MTBF
Conditions
60 Seconds
500VDC
100kHz, 1V
Min.
3000
10
---
70
Typ.
---
---
60
100
Max.
---
---
100
120
Units
VDC
GΩ
pF
kHz
Exceeding the unit absolute maximum ratings could cause damage.
These are not continuous operating ratings.
MIL-HDBK-217F
@25°C
Ground Benign
2
---
---
MHrs
Environmental Characteristics
Parameter
Operating
Temperature
Operating
Temperature
Storage
Temperature
Humidity
Cooling
Output Characteristics
Max. Units
85
90
125
°C
°C
°C
%
Parameter
Line Regulation
Load Regulation
Ripple & Noise
Short Circuit
Conditions
For Vin Change of
1%
Io = 20% to 100%
20MHz BW
Min.
---
Typ.
±1.2
Max.
±1.5
Units
%
%
mV P-P
Conditions
Ambient
Case
Min.
-40
-40
-40
See Selection Guide
---
65
100
---
95
Free-Air Convection
0.5 Second Max.
Maximum Capacitive Load
Derating Curve (3.3, 5 & ±5V Outputs)
100
80
Output Power (%)
100LFM
Natural
convection
200LFM
Models by Output Voltage
(Each Output on Duals)
Singles
220
Duals
100
Units
uF
400LFM
60
Notes:
1. Specifications typical at Ta=+25°C, resistive load, nominal input
voltage, rated output current unless otherwise noted.
2. These power converters require a minimum output load to maintain
specified regulation.
3. Operation under no-load conditions will not damage these modules;
however, they may not meet all specifications listed.
4. All DC/DC converters should be externally fused at the front end for
protection.
5. Other input and output voltage may be available, please contact
factory.
6. All specifications subject to change without notice.
7. For detailed data sheet, please visit our website.
40
20
0
-40
¡ã
50
60
70
80
]
90
100
110
Ambient Temperature
Derating Curve (Other Outputs)
100
80
Output Power (%)
100LFM
400LFM
200LFM
60
Natural
convection
40
20
0
-40
¡ã
50
60
70
80
]
90
100
110
Ambient Temperature
2463 208th Street, Ste. 205
Torrance, CA 90501
Tel: (310) 533-1455
Fax: (310) 533-1853
http://www.mpsind.com
E-mail: sales@mpsind.com