Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
1,000 Vrms for 1min. (Detection current: 10mA.)
4,000 Vrms for 1min. (Detection current: 10mA.)
Min. 10,000 V
Max. 55°C (By resistive method, nominal voltage applied to the coil, max. switching current.)
Max. 20 ms [20 ms] (Nominal voltage applied to the coil, excluding contact bounce time.)
Max. 20 ms [20 ms] (Nominal voltage applied to the coil, excluding contact bounce time.)
Min. 200 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Min. 1,000 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 2 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 3 mm
Min. 5×10
6
(at 180 times/min.)
Min. 10
5
(at 16A 250V AC): 1 Form C, 1 Form A, 1 Form B
Min. 10
5
(at 10A 250V AC): 2 Form C, 2 Form A, 2 Form B, 1 Form A 1 Form B
Ambient temperature: –40°C to +70°C
–40°F to +158°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Approx. 14 g
.49 oz
Rating
Surge breakdown
Between contact and coil
voltage*
2
(Initial)
Temperature rise (coil) (at 70°C
158°F)
Operate time [Set time] (at 20°C
68°F)
Release time [Reset time] (at 20°C
68°F)
Functional
Destructive
Functional
Vibration resistance
Destructive
Mechanical
Shock resistance
Electrical (Resistive load)*
3
(at 20 times/min.)
Conditions for operation, transport and storage*
4
Mechanical
characteristics
Expected life
Conditions
Unit weight
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of
±1.2×50µs
according to JEC-212-1981
*3. In order to obtain the full rated life cycles, the relay should be properly vented by removing the vent nib. More detail, please look at caution for NOTES.
*4. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
ASCTB176E 201202-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
DJ (ADJ)
REFERENCE DATA
1. Max. switching capacity
2. Temperature rise
Tested sample: ADJ12024, 6 pcs.
Coil applied voltage: 0%V, Contact current: 16 A, 20 A
Measured portion: Contact, Ambient temperature:
25°C
77°F,
85°C
185°F
100
Temperature rise,
°C
AC resistive load
(1-pole)
40
35
30
25
20
15
10
5
0
10
100
Contact voltage, V
1,000
0
0
5
10
15
20
25
0
90
100
110
120
130
140
3. Coil temperature rise
Tested sample: ADJ56024, 6 pcs.
Coil applied voltage: 100%V, 130%V of rating
Contact current: 0 A, 10 A
Measured portion: Inside the coil, Ambient
temperature: Room temperature, 70°C
158°F
50
Temperature rise,
°C
10A
room temperature
10A 70°C
0A
room temperature
0A 70°C
20
+25°C
+85°C
Contact current, A
40
AC resistive load
(2-pole)
30
10
10
Contact current, A
Coil applied voltage, %V
4. Set and Reset time
Tested sample: ADJ12024, 10 pcs
Coil applied voltage: 80%V, 100%V, 120%V of rating
30
5. Ambient temperature characteristics
Tested sample: ADJ12024, 6pcs
Ambient temperature: –40°C to 85°C
–40°F to 185°F
30
Change rate
to nominal V, %V
20
10
Set
Reset
6. Influence of adjacent mounting
Tested sample: ADJ12024, 6pcs
Ambient temperature: Room temperature
25
20
15
10
5
0
70
Max.
x
Min.
Change rate to nominal V, %V
5
0
–5
Set voltage
OFF
OFF
5
0
–5
OFF
Reset voltage
Set and Reset time, ms
–60 –40 –20
0
20 40 60 80 100
Ambient
temperature,
°C
–10
–20
–30
80
90
100
110
120
130
0
2
4
6
8
10
12
Coil applied voltage, %V
Distance between relays , mm
DIMENSIONS
(mm
inch)
1. 1 Form C, without a test button
CAD Data
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/