Series AM2F-Z
2 Watt | DC-DC Converter
FEATURES:
•
•
•
•
RoHS compliant
12 Pin SIP Package
Low ripple and noise
High efficiency up to 70%
•
•
•
Operating temperature -40 C to + 85 C
Input / Output Isolation 1000, 3000 or 5200VDC
Pin compatible with multiple manufacturers
o
o
Models
Single output
Input/Output Isolation 1000VDC
Model
Input Voltage
(V)
Output Voltage
(V)
3.3
5
7.2
9
12
15
18
24
3.3
5
7.2
9
12
15
18
24
3.3
5
7.2
9
12
15
18
24
3.3
5
7.2
9
12
15
18
24
3.3
5
7.2
9
12
15
18
24
3.3
5
Output Current
max (mA)
600
400
278
222
167
134
111
83
600
400
278
222
167
134
111
83
600
400
278
222
167
134
111
83
600
400
278
222
167
134
111
83
600
400
278
222
167
134
111
83
600
400
Capacitive load,
max (μF)
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
Efficiency
(%)
64
66
64
66
70
70
67
68
64
66
63
66
70
70
66
68
54
64
63
64
68
68
68
70
64
66
64
66
70
70
67
68
64
66
63
66
70
70
66
68
64
64
AM2F-0503SZ
4.5-5.5
AM2F-0505SZ
4.5-5.5
AM2F-0507SZ
4.5-5.5
AM2F-0509SZ
4.5-5.5
AM2F-0512SZ
4.5-5.5
AM2F-0515SZ
4.5-5.5
AM2F-0518SZ
4.5-5.5
AM2F-0524SZ
4.5-5.5
AM2F-1203SZ
10.8-13.2
AM2F-1205SZ
10.8-13.2
AM2F-1207SZ
10.8-13.2
AM2F-1209SZ
10.8-13.2
AM2F-1212SZ
10.8-13.2
AM2F-1215SZ
10.8-13.2
AM2F-1218SZ
10.8-13.2
AM2F-1224SZ
10.8-13.2
AM2F-2403SZ
21.6-26.4
AM2F-2405SZ
21.6-26.4
AM2F-2407SZ
21.6-26.4
AM2F-2409SZ
21.6-26.4
AM2F-2412SZ
21.6-26.4
AM2F-2415SZ
21.6-26.4
AM2F-2418SZ
21.6-26.4
AM2F-2424SZ
21.6-26.4
Input/Output Isolation 3000VDC
AM2F-0503SH30Z
4.5-5.5
AM2F-0505SH30Z
4.5-5.5
AM2F-0507SH30Z
4.5-5.5
AM2F-0509SH30Z
4.5-5.5
AM2F-0512SH30Z
4.5-5.5
AM2F-0515SH30Z
4.5-5.5
AM2F-0518SH30Z
4.5-5.5
AM2F-0524SH30Z
4.5-5.5
AM2F-1203SH30Z
10.8-13.2
AM2F-1205SH30Z
10.8-13.2
AM2F-1207SH30Z
10.8-13.2
AM2F-1209SH30Z
10.8-13.2
AM2F-1212SH30Z
10.8-13.2
AM2F-1215SH30Z
10.8-13.2
AM2F-1218SH30Z
10.8-13.2
AM2F-1224SH52Z
10.8-13.2
AM2F-2403SH30Z
21.6-26.4
AM2F-2405SH30Z
21.6-26.4
Models
www.aimtec.com
F 051e R6.B
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2F-Z
2 Watt | DC-DC Converter
Single output (continued)
Input/Output Isolation 3000VDC
Model
Input Voltage
(V)
Output Voltage
(V)
7.2
9
12
15
18
24
3.3
5
7.2
9
12
15
18
24
3.3
5
7.2
9
12
15
18
24
3.3
5
7.2
9
12
15
18
24
Output Current
max (A)
278
222
167
134
111
83
600
400
278
222
167
134
111
83
600
400
278
222
167
134
111
83
600
400
278
222
167
134
111
83
Capacitive load,
max (μF)
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
470
Efficiency
(%)
63
64
68
68
68
70
53
66
64
66
70
70
67
68
53
66
63
66
70
70
66
68
54
64
63
64
68
68
68
70
AM2F-2407SH30Z
21.6-26.4
AM2F-2409SH30Z
21.6-26.4
AM2F-2412SH30Z
21.6-26.4
AM2F-2415SH30Z
21.6-26.4
AM2F-2418SH30Z
21.6-26.4
AM2F-2424SH30Z
21.6-26.4
Input/Output Isolation 5200VDC
AM2F-0503SH52Z
4.5-5.5
AM2F-0505SH52Z
4.5-5.5
AM2F-0507SH52Z
4.5-5.5
AM2F-0509SH52Z
4.5-5.5
AM2F-0512SH52Z
4.5-5.5
AM2F-0515SH52Z
4.5-5.5
AM2F-0518SH52Z
4.5-5.5
AM2F-0524SH52Z
4.5-5.5
AM2F-1203SH52Z
10.8-13.2
AM2F-1205SH52Z
10.8-13.2
AM2F-1207SH52Z
10.8-13.2
AM2F-1209SH52Z
10.8-13.2
AM2F-1212SH52Z
10.8-13.2
AM2F-1215SH52Z
10.8-13.2
AM2F-1218SH52Z
10.8-13.2
AM2F-1224SH52Z
10.8-13.2
AM2F-2403SH52Z
21.6-26.4
AM2F-2405SH52Z
21.6-26.4
AM2F-2407SH52Z
21.6-26.4
AM2F-2409SH52Z
21.6-26.4
AM2F-2412SH52Z
21.6-26.4
AM2F-2415SH52Z
21.6-26.4
AM2F-2418SH52Z
21.6-26.4
AM2F-2424SH52Z
21.6-26.4
Input Specifications
Parameters
Voltage range
Nominal
5
12
24
Typical
4.5-5.5
10.8-13.2
21.6-25.4
Capacitor
Maximum
Units
VDC
Filter
Turn on Transient process time
Start up time
Absolute Maximum Rating
Peak Input Voltage time
5 Vin
12 Vin
24 Vin
100
300
0-7
0-15
0-28
100
ms
ms
VDC
ms
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Conditions
3 sec
Typical
> 1000
60
Rated
1000, 3000 or 5200
Units
VDC
MOhm
pF
www.aimtec.com
F 051e R6.B
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2F-Z
2 Watt | DC-DC Converter
Output Specifications
Parameters
Voltage accuracy
Short Circuit protection
Short Circuit restart
Line voltage regulation (Single)
Load voltage regulation (Single)
Load voltage regulation (Single)
3.3V output model
Temperature coefficient
Ripple & Noise
Rising time
Conditions
Typical
±2
Continuous
Auto-recovery
Maximum
Units
%
Load 0 – 100%
Load 0 – 100%
At 20MHz
Bandwidth
±0.5
±0.5
±1.5
±0.02
75
150
%
%
%
%/ C
mV p-p
ms
o
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Max Case temperature
Cooling
Humidity
Case material
Weight
Dimensions
(L x W x H)
MTBF
Conditions
100% load
Full Load without Derating
Typical
50
-40 to +85
-40 to +125
Maximum
Units
KHz
o
C
o
C
o
C
%
%
90
Free air convection
90
Plastic UL94-VO
g
3.8
1.25 x 0.34 x 0.53 inches
31.80 x 8.60 x 13.47 mm
o
>1 500 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25 C)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load
unless otherwise specified
Pin Out Specifications
Pin
1
2
3
9
10
11
12
Dimensions
3000 and 5200VDC
+V Input
-V Input
N.C.
N.C.
-V Output
+V Output
N.C.
13.47
(0.53)
31.80
(1.25)
PRINTED
FACE
13.97
(0.55)
8.60
(0.34)
1000VDC
+V Input
N.C.
N.C.
N.C.
-V Output
+V Output
-V Input
0.50
(0.02)
2.54
(0.10)
27.94
(1.10)
3.05
(0.12)
8.60
(0.34)
3.81
(0.15)
0.50
(0.02)
0.25
(0.01)
0.50
(0.02)
NOTE: 1.
Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications.
2.
Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured.
3.
Mechanical drawings and specifications are for reference only.
4.
All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified.
5.
Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release.
6.
This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet.
7.
Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R6.B
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only