Series AMEGR11/15-KZ
up to 350mA | AC-DC LED driver
FEATURES:
•
AC-DC Constant Current LED Driver
•
Universal Input: 90-264VAC, 47-63Hz
•
Short circuit protection
•
RoHS compliant
•
•
•
•
Waterproof IP67 case
Over current protection
Over voltage protection
Low output ripple
Models
Single output
Model
AMEGR11-3630KZ
AMEGR15-5030KZ
Max Output
Power
(W)
*
12.6
17.5
Output Voltage
Range
(V)
15-36
25-50
Output Current
(mA)
325 ±25
325 ±25
Input Voltage
(VAC/Hz)
90-264/47-63
90-264/47-63
Efficiency
(%)
75
75
*
Exceeding the maximum output power will permanently damage the converter
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Inrush current <2ms
Leakage current
AC current
No-load consumption
External fuse
115V
230V
115V
230V
Conditions
Typical
90-264
10
20
0.25
0.1
0.06
2
Maximum
Units
VAC
A
mA
A
W
250V/1.5A
Output Specifications
Parameters
Current accuracy
Line regulation
Load regulation
Ripple & Noise
Hold-up time (min)
Conditions
LL-HL
30V to 100% load
Typical
±10
±5
±10
100
4
Maximum
Units
%
%
%
mV p-p
ms
8
Isolation Specifications
Parameters
Tested I/O voltage
Input FG
Isolation resistance
Conditions
5mA/60Sec
Typical
3000
1500
>50
Maximum
Units
VAC
VAC
MΩ
General Specifications
Parameters
Switching frequency
Over current protection
Over voltage protection
Short circuit protection
Short Circuit restart
Operating temperature
*
Maximum case temperature
Conditions
Typical
100
120
Zener Diode clamp
Continuous
Auto-Recovery
-30 to +55
Maximum
Units
KHz
%
o
90
o
C
C
www.aimtec.com
F 052.1e R1.B
Tel: +1 514 620 2722
1 of 2
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEGR11/15-KZ
up to 350mA | AC-DC LED driver
General Specifications (continued)
Parameters
Storage temperature
Temperature coefficient
Cooling
Humidity
Case material
Weight
Dimensions
(L X H X W)
MTBF
Conditions
Typical
-40 to +80
0.05
Free Air Convection
Maximum
Units
C
% /
o
C
o
95
Aluminum
178
6.40 x 1.04 x 0.85 inches 160.00 x 26.50 x 21.50 mm
50,000 hrs (MIL-HDBK-217 F at +25
o
C)
% RH
g
*NOTE:
Converters do NOT have over temperature protection and will be damaged if their maximum case temperature is
exceeded.
Safety Specifications
Parameters
Agency approvals
Standards
CE
GB195110.1-2004/IEC61347-1:2003, EN55015, EN61000, EN61547
Dimensions
NOTE: 1.
Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications.
2.
Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured.
3.
Mechanical drawings and specifications are for reference only.
4.
All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified.
5.
Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release.
6.
This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet.
7.
Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052.1e R1.B
21.50
(0.85)
26.50
(1.10)
Tel: +1 514 620 2722
2 of 2
Toll free: + 1 888 9 AIMTEC
(924 6832)