NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Current
Inrush current <2ms (cold start)
Leakage current
External fuse
www.aimtec.com
F 052e R8.H
Conditions
115VAC
230VAC
115VAC
230VAC
slow blow type
Tel: +1 514 620 2722
1 of 4
Typical
0.46
0.29
Maximum
10
20
0.25
Units
A
A
A
A
mA
A
1.5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL20-MAZ
20 Watt | AC-DC Converter
Input Specifications (continued)
Parameters
Input dissipation
Start up time
Conditions
No Load
Soft start
Typical
<0.5
500
Maximum
Units
W
ms
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation (single output)
Load regulation (dual output)
Transient recovery time
Transient response deviation
Ripple & Noise*
Hold-up time (min)
Conditions
0-100% load
Unbalanced (0-100%) load
25% load step
3.3 & 5V models
12, 15 & 24V models
110VAC
230VAC
Typical
±2
±1
±2
±3
500
±2
75
100
10
25
Maximum
Units
%
%
%
%
µs
% of Vout
mV p-p
ms
*
Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) parallel capacitor.
Isolation Specifications
Parameters
Tested I/O voltage
Isolation resistance
Isolation Capacitance
Conditions
3 sec, 1.2mA
Typical
>1000
2200
Rated
4000
Units
VAC
MΩ
pF
General Specifications
Parameters
Switching frequency
Over load protection
Over voltage protection
Short circuit protection
Short circuit restart
Operating temperature
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Humidity
Case material
Weight
Dimensions
(L x W x H)
MTBF
Conditions
100% load
Auto recovery, Foldback
Typical
65
150
Zener Diode Clamp
Continuous
Auto recovery
-40 to 80
Maximum
Units
KHz
%
With derating above 50ºC
100
-45 to +95
±0.02
Free air convection
Non condensing
20 ~ 95
Plastic resin + Fiberglass (flammability to UL 94V-0)
70
2.22 x 1.21 x 0.99 inches
56.48 x 30.86 x 25.10mm
> 400 000 hrs (MIL-HDBK -217F, t=+25
o
C)
C
C
o
C
% /
o
C
o
o
% RH
g
Environment Approval
Test
Parameters
Wave form
Acceleration amplitude
Bump duration
Converter operation
Number of bumps
Test mode
Displacement
Acceleration
Converter operation
Shock
Vibration
Conditions
Half sine wave
5gn
30 ms
before and after test, body mounted (on chassis)
18 (3 in each direction for every axis)
Sweep sine
1mm
3g
10-100Hz, speed 0.05Hz/s
www.aimtec.com
F 052e R8.H
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL20-MAZ
20 Watt | AC-DC Converter
Safety Specifications
Parameters
Agency approvals
cULus, CE, CB
Medical Electrical Equipment
Information technology Equipment
EMI - Conducted and radiated emission
Harmonic Current Emissions
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
IEC\EN\UL 60601-1, CSA-C22.2 No. 601.1-M90
EN 60950-1:2006+A11:2009
EN55011, class B
IEC/EN 61000-3-2, (EN60555-2)
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
Standards
Pin Out Specifications
Pin
1
2
3
4
5
Single
AC Input (N)
AC Input (L)
+V Output
-V Output
No pin
Dual positive
AC Input (N)
AC Input (L)
+V1 Output
Common
+V2 Output
Dual negative/positive
AC Input (N)
AC Input (L)
+V1 Output
Common
-V2 Output
Dimensions
5.27
(0.21)
30.86
(1.21)
20.40
(0.80)
25.10
(0.99)
5,27
(0.21)
www.aimtec.com
F 052e R8.H
8.00
(0.31)
Tel: +1 514 620 2722
3 of 4
10.20
(0.40)
10.20
(0.40)
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL20-MAZ
20 Watt | AC-DC Converter
Derating
Free Air Convection
50?C
100
Output Power (%)
80
60
40
20
0
- 40
- 20
0
20
40
60
80
85
Safe Operating Area
100
Ambient Temperature
?C
NOTE: 1.
Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer
controlled by Aimtec; refer to www.aimtec.com for the most current product specifications.
2.
Product labels shown, including safety agency certifications on labels, may
vary based on the date manufactured.
3.
Mechanical drawings and specifications are for reference only.
4.
All specifications are measured at an ambient temperature of
25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified.
5.
Aimtec may not have conducted destructive testing or chemical analysis
on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be
available for release.
6.
This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other
such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet.