IP Rating ............................................................ IP 40 .....................................................................IP 40
*RoHS Directive 2002/95/EC Jan 27 2003 including Annex
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
Model 91, 92, 93, 94 & 95 - 5/8 ” Square Single-Turn Panel Control
Mechanical Characteristics
1
Stop Strength (1/4 ” D shaft) .............................................................................................................................................45.19 N-cm (4 lb.-in.)
(1/8 ” D shaft) .............................................................................................................................................33.89 N-cm (3 lb.-in.)
Starting ........................................................................................................................................... 0.3 max. above average running torque
Running Torque
Single or Dual Section (A & R Bushings) .................................................................................................. 0.21 to 1.06 N-cm (0.3 to 1.5 oz.-in.)
Single or Dual Section (C & U Bushings) .................................................................................................. 0.14 to 1.06 N-cm (0.2 to 1.5 oz.-in.)
Mounting .............................................................................................................................................1.7-2.0 N-m (15-18 lb.-in.) maximum
Variation ...................................................................................................................... 0.35 N-cm (0.5 oz.-in.) maximum in 45 ° shaft travel
Weight (Single Section, Metal Bushing)...............................................................................................................................12.7 grams nominal
Terminals .................................................................................................................................Printed circuit terminals, J-Hooks or solder lugs
Soldering Condition ...........................................Recommended hand soldering using Sn95/Ag5 no clean solder, 0.025 ” wire diameter.
Maximum temperature 399 °C (750 °F) for 3 seconds. No wash process to be used with no clean flux.
Marking ..................................................................................Manufacturer’s trademark, date code, resistance, manufacturer’s part number
Ganging (Multiple Section Potentiometers).............................................................................................................................2 cups maximum
Hardware ...................One lockwasher and one mounting nut is shipped with each potentiometer, except where noted in the part number.
NOTE:
1
At
Performance specifications do not apply to units subjected to printed circuit board cleaning procedures.
room ambient: +25 °C nominal and 50 % relative humidity nominal, except as noted.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
Model 91, 92, 93, 94 & 95 - 5/8 ” Square Single-Turn Panel Control
Product Dimensions
Model 91 PC Pin Terminals, In-Line
22.86 ± 0.43
(.900 ± .017)
MOUNTING
SURFACE
12.70 ± .229
(.500 ± .009)
0.79 ± .025
(.031 ± .010)
DIA.
13.72 ± 0.38
(.540 ± .015)
1.37 ± 0.08
(.054 ± .003)
2.36 ± 0.08
(.093 ± .003)
15.88
(.625)
7.92
(.312)
Model 92 J-Hooked
Terminals, In-Line
.79
(.031) 2 PLCS.
3 2 1
SEE
HOW TO ORDER
CHART FOR
BUSHING OPTIONS.
10.16 ± 0.30
(.400 ± .012)
11.05 ± 0.20
(.435 ± .008)
SEE
NEXT PAGE
FOR SHAFT
OPTIONS.
2.54
(.100)
2.54
(.100)
1.19
(.047)
“A” STYLE
A.R. LUG
R
9.53
(.375)
15.29 ± 0.56
(.602 ± .022)
.254
(.010)
GAP
5.08
(.20)
1.52
(.06)
R2
R1
1
2
3
1
2
3
0.76 ± 0.05
(.030 ± .002)
TYP.
Model 94 J-Hooked
Terminals, "L" Pattern
Model 93 PC Pin Terminals, "L" Pattern
22.86 ± 0.43
(.900 ± .017)
MOUNTING
SURFACE
12.70 ± .229
(.500 ± .009)
0.79 ± .025
(.031 ± .010)
DIA.
13.72 ± 0.38
(.540 ± .015)
1.37 ± 0.08
(.054 ± .003)
2.36 ± 0.08
(.093 ± .003)
15.88
(.625)
7.92
(.312)
.81
(.032)
R. MAX.
5.33 ± .76
(.21 ± .03)
3.81
(.150)
MAX. TYP.
1.52
(.06)
GAP
3 2 1
SEE
HOW TO ORDER
CHART FOR
BUSHING OPTIONS.
DIA.
0.81
TYP.
(.032)
10.16 ± 0.30
(.400 ± .012)
R2
R1
5.08 ± 0.38
(.200 ± .015)
11.05 ± 0.20
(.435 ± .008)
SEE
NEXT PAGE
FOR SHAFT
OPTIONS.
1.19
(.047)
“A” STYLE
A.R. LUG
R
9.53
(.375)
12.70 ± 1.02
(.500 ± .040)
Shaft Flat Orientation
2.54
(.100)
2.54
(.100)
1
3
2
1
3
2
0.76 ± 0.05
(.030 ± .002)
TYP.
120 ° ± 5 ° STD.
FLAT ORIENTATION
(SHAFT AT CCW END)
1
CCW
2
POTENTIOMETER
3
Model 95 Solder Lug Terminals, "Triangular" Pattern
Longhai Hengsheng Automation Equipment Co., Ltd. specializes in sellingthe full range of German E+H productsAt present, we have mature production experience and high assembly production capacity. Our ...
I connected the PC to the coordinator via the serial port and used sensordemo for one module. After opening sensor monitor, the topology cannot be displayed. The sensor monitor is connected to the coo...
Has anyone modified the RTC function under WINCE60? I modified it according to the method under CE50, but why is the data reported abnormal in the OEMSETREALTIME() function? What is the difference bet...
[hide]Sometimes you may just need a little light so you don’t have to grope in the dark, especially when you are rummaging through boxes and cabinets and can’t find a small thing. An LED light in the ...
I am a sophomore this year, and I have to do a digital electronics course design at the end of the semester. In order to make the three digital tubes light up as required, there are as many as fourtee...
EtherCAT (Ethernet for Control Automation Technology) is a real-time industrial fieldbus communication protocol based on an Ethernet-based development framework. EtherCAT is one of the fastest indu...[Details]
On August 21st, Zhiyuan Robotics revealed at its first partner conference that it expects shipments to reach thousands of units this year and tens of thousands next year. The company hopes to reach...[Details]
For autonomous vehicles to safely navigate the road, they must identify far more complex objects than just traffic lights, pedestrians, and other familiar objects. Among these obstacles is a crucia...[Details]
Civilian internal combustion engines operate in the range of approximately 1000-4000 rpm. This results in the engine's kinetic energy being ineffective at low or high rpm, making starting difficult...[Details]
0 Introduction
Portable terminals integrate a computer and display screen into a single device. Due to limited space in portable devices, previous designs often used a single-chip microcompute...[Details]
With the growth of the Internet of Things (IoT), wearable, and portable devices, consumers are growing weary of cluttered cables and the need for frequent battery recharges. The benefits of wireles...[Details]
When we pick up an unfamiliar object, the first thing we want to know is what it actually does. A drive shaft, as the name suggests, is a shaft that transmits power. It's the transmission medium th...[Details]
As automotive technology develops at an ever-increasing pace, the performance requirements for automotive internal structures, components, and accessories are becoming increasingly demanding. The d...[Details]
Thoughts triggered by the Wuhan Radish Run incident
It's so hot, even Ferraris spontaneously combust. A recent incident on a Wuhan overpass: a red Ferrari...[Details]
With the global number of new energy vehicles expected to exceed 45 million by 2025, the performance boundaries of battery management systems are being reshaped.
Infineon Technologies
'
...[Details]
Relying on Zena CSS and Arm's complete partner ecosystem, we will accelerate the implementation of autonomous driving.
Close your eyes and imagine yourself getting into your car, rea...[Details]
Currently, PLCs are widely used in various industries, including special machine tools, machine tools, control systems, building automation, steel, petrochemicals, electricity, building materials, ...[Details]
introduction
With the continuous development of electronic technology and the continuous upgrading of medical equipment, the demand for medical liquid infusion precision is becoming increasing...[Details]
The question of the benefits and drawbacks of DC and AC charging for electric vehicles is a common concern among electric vehicle users. Currently, there are two types of charging stations and meth...[Details]
Today, we'll discuss why contactors shouldn't be connected to the output terminals of VFDs. This is because if the contactor at the VFD output isn't engaged, it will only engage when the VFD starts...[Details]