EEWORLDEEWORLDEEWORLD

Part Number

Search

RHT300.0UP031C207111Z14

Description
Absolute Magnetostrictive Sensor
CategoryThe sensor    Sensor/transducer   
File Size2MB,14 Pages
ManufacturerMTS Sensors
Websitehttps://www.mtssensors.com
Download Datasheet Parametric View All

RHT300.0UP031C207111Z14 Overview

Absolute Magnetostrictive Sensor

RHT300.0UP031C207111Z14 Parametric

Parameter NameAttribute value
MakerMTS Sensors
Reach Compliance Codeunknow
Other featuresIP 67, IP 68
Linearity(%)0.01 %
Maximum operating temperature75 °C
Minimum operating temperature-40 °C
resolution5 µm
Sensor/Transducer TypeLINEAR POSITION SENSOR,MAGNETOSTRICTIVE,ABSOLUTE
Maximum supply voltage28.8 V
Minimum supply voltage20.4 V
Termination typeCABLE
Base Number Matches1
Temposonics
®
®
Magnetostrictive, Absolute, Non-contact
Linear-Position Sensors
R-Series Models RP and RH
CANbus Outputs (CANopen/CANbasic)
Data Sheet
SENS
O
RS
Document Part Number
550991 Revision D
Model RP Profile-style position sensor
FEATURES
Linear, Absolute Measurement
LEDs For Sensor Diagnostics
Superior Accuracy, Resolution down to 2 μm
Non-Contact Sensing Technology
Linearity Deviation Less Than 0.01%
Repeatability Within 0.001%
Direct CAN Output (Position + Velocity)
Model RH Rod-style position sensor
Time-based Magnetostrictive position sensing principle
Movable position magnet
Magnetic field encompasses
entire waveguide - generated
by the interrogation pulse
Interrogation
Return wire
Waveguide
Strain-Pulse detector
Bias magnet
Magnetic field from
position magnet
Interaction of magnetic
fields causes waveguide to
generate a strain pulse
BENEFITS
Rugged Industrial Sensor
Selectable Bus Termination (CANopen)
CANopen with Heartbeat Function
APPLICATIONS
Continuous Operation In Harsh Industrial Conditions
High Pressure Conditions
For Accurate, Multi-Magnet Position Measurement
(up to 20 positions per sensor)
TYPICAL INDUSTRIES
Factory Automation
Fluid Power
Plastic Injection and Blow Molding
Material Handling and Packaging
Benefits of Magnetostriction
Temposonics linear-position sensors use the time-based
magnetostrictive position sensing principle developed by MTS.
Within the sensing element, a sonic-strain pulse is induced in a
specially designed magnetostrictive waveguide by the momentary
interaction of two magnetic fields. One field comes from a moveable
permanent magnet that passes along the outside of the sensor. The
other field comes from an “interrogation” current pulse applied along
the waveguide. The resulting strain pulse travels at sonic speed along
the waveguide and is detected at the head of the sensing element.
The position of the magnet is determined with high precision and
speed by accurately measuring the elapsed time between the applica-
tion of the interrogation pulse and the arrival of the resulting strain
pulse with a high-speed counter. The elapsed time measurement is
directly proportional to the position of the permanent magnet and is
an absolute value. Therefore, the sensor's output signal corresponds
to absolute position, instead of incremental, and never requires
recalibration or re-homing after a power loss. Absolute, non-contact
sensing eliminates wear, and guarantees the best durability and
output repeatability.
All specifications are subject to change. Contact MTS for specifications and
engineering drawings that are critical to your application. Drawings contained
in this document are for reference only. Go to http://www.mtssensors.com for
the latest support documentation and related media.
FPGA_100 Days Journey_if_else and case.pdf
FPGA_100 Days Journey_if_else and case.pdf...
zxopenljx FPGA/CPLD
How to tell how many layers a PCB board has?
As the title says, if the wiring is a single-sided board on one side and a double-sided board on the other two sides, how can we tell whether it is a four-layer board or an eight-layer board? Or more?...
suoma PCB Design
Based on PSOC6 development board simulation I2C solution X-NUCLEO-IKS01A3 LIS2DW12
Today we analyze LIS2DW12, simulate the IIC interface, and verify the ID first:uint8_t LIS2DW12_Read_Date(uint8_t SlaveAddress, uint8_t RegAddress) {uint8_t recvDate;uint8_t succ, stime=0;I2C_Start();...
DavidZH MEMS sensors
Research on HDI filling process
Research on HDI filling process...
lorant RF/Wirelessly
Experts please give me some advice on the interrupt vector table
When using LF2407 external RAM to debug a program, does the interrupt vector table have to be burned into FLASH first? Now I use the external SRAM to debug the program, and the interrupt vector table ...
liangguolin Microcontroller MCU
Signal receiving circuit
...
探路者 Mobile and portable

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1047  2323  1011  2906  2607  22  47  21  59  53 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号