The AHV Series of DC/DC converters are designed to
replace the AHE/ATO family of converters in applications
requiring compliance to MIL-STD-704A through E, in
particular the input surge requirement of 80V specified to
withstand transient input voltage of 80V. No input voltage
or output power derating is necessary over the full military
temperature range.
These converters are packaged in an extremely rugged,
low profile package that meets all requirements of MIL-
STD-883 and MIL-PRF-38534. Parallel seam weld sealing
and the use of ceramic pin feed thru seals assure long
term hermeticity after exposure to extended temperature
cycling.
The basic circuit is a push-pull forward topology using
power MOSFET switches. The nominal switching
frequency is 500KHz. A unique current injection circuit
assures current balancing in the power switches. All AHV
series converters use a single stage LC input filter to
attenuate input ripple current. A low power 11.5V series
regulator provides power to an epitaxial CMOS custom
pulse width modulator integrated circuit. This single
integrated circuit provides all PWM primary circuit
functions. Power is transferred from primary to secondary
through a ferrite core power transformer. An error voltage
signal is generated by comparing a highly stable reference
voltage with the converter output voltage and drives the
PWM through a unique wideband magnetic feedback
circuit. This proprietary feedback circuit provides an
extremely wide bandwidth, high gain control loop, with
high phase margin. The feedback control loop gain is
insensitive to temperature, radiation, aging, and variations
in manufacturing. The transfer function of the feedback
circuit is a function of the feedback transformer turns ratio
which cannot change when subjected to environmental
extremes.
Manufactured in a facility fully qualified to MIL-PRF-38534,
these converters are fabricated utilizing DSCC qualified
processes. For available screening options, refer to device
screening table in the data sheet. Variations in electrical,
mechanical and screening can be accommodated.
Contact IR Santa Clara for special requirements.
28V Input, Single, Dual and Triple Output
AHV
Features
n
n
n
n
n
n
n
n
n
n
n
n
n
n
80V Transient Input (100 msec max.)
50V DC Input (Continous)
16V to 40V DC Input Range
Single, Dual and Triple Outputs
15W Output Power
(No Temperature Derating)
Low Input / Output Noise
Full Military Temperature Range
Wideband PWM Control Loop
Magnetic Feedback
Low Profile Hermetic Package (0.405”)
Short Circuit and Overload Protection
Constant Switching Frequency (500KHz)
True Hermetic Package (Parallel Seam
Welded, Ceramic Pin Feedthru)
Standard Microcircuit Drawings Available
www.irf.com
1
12/13/06
AHV28XX Series
T
CASE
= -55°C to +125°C, V
IN
= +28V
±
5% unless otherwise specified
Specifications (Single Output Models)
Absolute Maximum Ratings
Input voltage
Power output
Soldering temperature
Operating case temperature
Storage case temperature
Condition
-55°C
≤
T
C
≤
+125°C,
V
IN
= 28 V
DC
±5%,
C
L
=0,
unless otherwise specified
-0.5V to +50VDC (Continous), 80V (100 msec)
Internally limited, 17.5W typical
300°C for 10 seconds (1 pin at a time)
-55°C to +125°C
-65°C to +135°C
TEST
STATIC
CHARACTERISTICS
OUTPUT
Voltage
Current
Ripple Voltage
1
Power
REGULATION
Line
Load
INPUT
Current
Ripple Current
EFFICIENCY
ISOLATION
SYMBOL
Group A
Subgroups
AHV2805S
Min
Max
AHV2812S
Min
Max
AHV2815S
Min
Max
Units
V
OUT
I
OUT
V
RIP
P
OUT
VRLINE
VRLOAD
I
IN
I
RIP
E
FF
ISO
V
IN
= 16, 28, and 40 VDC
I
OUT
= 0
V
IN
= 16, 28, and 40 VDC
V
IN
= 16, 28, and 40 VDC
BW = DC to 1 MHz
V
IN
= 16, 28, and 40 VDC
V
IN
= 16, 28, and 40 VDC
I
OUT
= 0, half load and full load
VIN = 16, 28, and 40 VDC
I
OUT
= 0, half load and full load
I
OUT
= 0, Inhibit (pin 2) = 0
I
OUT
= 0, Inhibit (pin 2) = Open
I
OUT
= Full load
I
OUT
= Full Load
T
C
= +25°C
Input to output or any pin to
case (except pin 8) at 500
VDC
TC = +25°C
No effect on DC performance
TC = +25°C
Overload, TC = +25°C
Short Circuit, TC = +25°C
I
OUT
= Full Load
4
1
2,3
1,2,3
1,2,3
1,2,3
1
2,3
1,2,3
1,2,3
1,2,3,
1
1
4.95
4.90
0.0
15
5.05
5.10
3.00
60
11.88
11.76
0.0
15
12.12
12.24
1.25
60
14.85
14.70
0.0
15
15.15
15.30
1.00
60
V
V
A
mVp-p
W
5.0
25
50
18
50
50
72
100
72
100
30
60
120
18
50
50
72
100
35
75
150
18
50
50
mV
mA
mA
mAp-p
%
MΩ
Capacitive Load
2,3
Load Fault
Power Dissipation
Switching Frequency
DYNAMIC
CHARACTERISTICS
Step Load Changes
Output Transient
5
Recovery
5,6
C
L
P
D
F
S
4
1
500
8.5
8.5
450
550
450
200
8,5
8.5
550
450
200
8.5
8.5
550
µF
W
4
KHz
VOT
LOAD
TT
LOAD
50% Load
135
100% Load
No Load
135
50%
50% Load
135
100%
No Load
335
50% Load
50% Load
335
No lLoad
Input step 16 to 40 VDC
3,7
Input step 40 to 16 VDC
3,7
Input step 16 to 40 VDC
3,6,7
Input step 40 to 16 VDC
3,6,7
I
OUT
= OA and Full Load
I
OUT
= O and Full Load
8
V
IN
= 16 to 40 VDC
4
4
4
4
4
4
4
4
4
4,5,6
4,5,6
4,5,6
-300
-500
+300
+500
70
200
5.0
300
-1000
800
800
550
10
10
-300
-750
+300
+750
70
1500
5.0
500
-1500
800
800
750
10
10
-300
-750
+300
+750
70
1500
5.0
500
-1500
800
800
750
10
10
mVpk
mVpk
µs
µs
ms
mVpk
mVpk
µs
µs
mVpk
ms
ms
Step Line Changes
Output Transient
Recovery
TURN-ON
Overshoot
Delay
Load Fault Recovery
VOT
LINE
TT
LINE
VTon
os
T on D
TR
LF
Notes to Specifications (Single Output Models)
1. Bandwidth guaranteed by design. Tested for 20KHz to 2MHz.
2. Capacitive load may be any value from 0 to the maximum limit without affecting dc performance. A capacitive load in excess of the maximum limit will not disturb
loop stability but will interfere with the operation of the load fault detection circuitry, appearing as a short circuit during turn-on.
3. Parameter shall be tested as part of design characterization and after design or process changes. Thereafter shall be guaranteed to the limits specified.
4. An overload is that condition with a load in excess of the rated load but less than necessary to trigger the short circuit protection and is the condition of maximum
power dissipation.
5. Load step transition time between 2µs to 10µs.
6. Recovery time is measured from the initiation of the transient to where V
OUT
has returned to within
±1%
of V
OUT
at 50% load.
7. Input step transition time between 2µs and 10µs.
8. Turn on delay time measurement is for either a step application of power at input or the removal of a ground signal from the inhinbit pin (pin 2) while power is
applied to the input. Above 125°C case temperature, derate output power linearly to 0 at 135°C case.
2
www.irf.com
AHV28XX Series
Specifications (Dual Output Models)
T
CASE
= -55°C to +125°C, V
IN
= +28V
±
5% unless otherwise specified
Absolute Maximum Ratings
Input voltage
Power output
Soldering temperature
Operating case temperature
Storage case temperature
Condition
-55°C
≤
T
C
≤
+125°C,
V
IN
= 28 V
DC
±5%,
C
L
=0,
unless otherwise specified
-0.5V to +50VDC (Continous), 80V (100 msec)
Internally limited, 17.5W typical
300°C for 10 seconds (1 pin at a time)
-55°C to +125°C
-65°C to +135°C
TEST
STATIC
CHARACTERISTICS
OUTPUT
Voltage
1
Current
1,2
Ripple Voltage
1,3
Power
1,2,4
REGULATION
Line
1,5
Load
1
SYMBOL
Group A
Subgroups
AHV2805D
Min
Max
AHV2812
Min
Max
AHV281D
Min
Max
Units
V
OUT
I
OUT
V
RIP
P
OUT
VR
LINE
I
OUT
VR
LOAD
I
IN
I
RIP
E
FF
ISO
I
OUT
= 0
V
IN
= 16, 28, and 40 VDC
V
IN
= 16, 28, and 40 VDC
BW = DC to 2 MHz
V
IN
= 16, 28, and 40 VDC
V
IN
= 16, 28, and 40 VDC
I
OUT
= 0, half load and full load
VIN = 16, 28, and 40 VDC
I
OUT
= 0, half load and full load
I
OUT
= 0, Inhibit (pin 2)
Tied to input return (pin 10)
I
OUT
= 0, Inhibit (pin 2) = Open
I
OUT
= Full load
BW = DC to 2MHz
I
OUT
= Full Load
T
C
= +25°C
Input to output or any pin to
case (except pin 8) at 500 VDC,
TC = +25°C
No effect on DC performance
TC = +25°C
Overload, TC = +25°C
8
Short Circuit, TC = +25°C
I
OUT
= Full Load
1
2,3
1,2,3
1,2,3
1,2,3
1
2,3
1,2,3
1,2,3
1,2,3,
1
1
4
1
±4.95
±4.90
0.0
15
±5.05
±5.10
±1500
60
±11.88
±11.76
0.0
15
±12.12
±12.24
±625
60
±14.85
±14.70
0.0
15
±15.15
±15.30
±500
60
V
V
mA
mVp-p
W
30
60
120
18
65
50
72
100
200
8,5
8.5
450
550
450
72
100
30
60
120
18
65
50
72
100
200
8,5
8.5
550
450
35
75
150
18
65
50
mV
INPUT
Current
Ripple Current
3
EFFICIENCY
ISOLATION
Capacitive Load
6,7
mA
mA
mAp-p
%
MΩ
C
L
P
D
F
S
200
8.5
8.5
550
µF
W
Load Fault
Power Dissipation
Switching Frequency
4
KHz
DYNAMIC
CHARACTERISTICS
Step Load Changes
Output Transient
9
Recovery
9,10
VOT
LOAD
TT
LOAD
50% Load
135
100% Load
No Load
135
50%
50% Load
135
100%
No Load
335
50% Load
50% Load
335
No lLoad
Input step 16 to
Input step 40 to
Input step 16 to
Input step 40 to
40 VDC
16 VDC
40 VDC
16 VDC
4
4
4
4
4
4
4
4
4
4,5,6
4,5,6
4,5,6
-300
-500
+300
+500
70
200
5.0
300
1000
4800
4800
550
10
10
-300
-500
+300
+500
70
1500
5.0
1200
-1500
4.0
4.0
600
10
10
-300
-500
+300
+500
70
1500
5.0
1500
-1500
4.0
4.0
600
10
10
mVpk
mVpk
µs
µs
ms
mVpk
mVpk
µs
µs
mVpk
ms
ms
Step Line Changes
Output Transient
7,11
Recovery
7,10, 11
VOT
LINE
TT
LINE
VTon
OS
T on D
TR
LF
TURN-ON
Overshoot
1
Delay
1,12
Load Fault Recovery
7
I
OUT
= O and Full Load
I
OUT
= O and Full Load
For Notes to Specifications, refer to page 5
www.irf.com
3
AHV28XX Series
Specifications (Triple Output Models)
T
CASE
= -55°C to +125°C, V
IN
= +28V
±
5% unless otherwise specified
Absolute Maximum Ratings
Input voltage
Power output
Soldering temperature
Operating case temperature
Storage case temperature
Condition
-55°C
≤
T
C
≤
+125°C,
V
IN
= 28 V
DC
±5%,
C
L
=0,
unless otherwise specified
-0.5V to +50VDC (Continous), 80V (100 msec)
Internally limited, 17.5W typical
300°C for 10 seconds (1 pin at a time)
-55°C to +125°C
-65°C to +135°C
TEST
STATIC
CHARACTERISTICS
OUTPUT
Voltage
1
SYMBOL
Group A
Subgroups
AHV2812T
Min
Max
AHV2815T
Min
Max
Units
V
OUT
I
OUT
= 0 (main)
I
OUT
= 0 (dual)
1
Current
1,2,3
Ripple Voltage
1,4
I
OUT
V
RIP
Power
1,2,3
P
OUT
V
IN
= 16, 28, and 40 VDC (main)
V
IN
= 16, 28, and 40 VDC (dual)
1
V
IN
= 16, 28, and 40 VDC
BW = DC to 2 MHz (main)
V
IN
= 16, 28, and 40 VDC
BW = DC to 2 MHz (main)
V
IN
= 16, 28, and 40 VDC (main)
(+dual)
(-dual)
(total)
V
IN
= 16, 28, and 40 VDC
I
OUT
= 0, 50%, and 100% load (main)
I
OUT
= 0, 50%, and 100% load (dual)
V
IN
= 16, 28, and 40 VDC
I
OUT
= 0, 50%, and 100% load (main)
I
OUT
= 0, 50%, and 100% load (dual)
I
OUT
= 0, Inhibit (pin 8)
Tied to input return (pin 10)
I
OUT
= 0
Inhibit (pin 2) = open
I
OUT
= 2000 mA (main)
I
OUT
=
±208mA
(±12V)
I
OUT
=
±167mA
(±15V)
BW = DC to 2MHz
I
OUT
= 2000mA (main)
I
OUT
=
±
208mA (
±
12V)
I
OUT
=
±167mA
(±15V)
Input to output or any pin to
case (except pin 7) at 500 VDC,
TC = +25
°
C
No effect on DC performance
TC = +25°C (main)
(dual)
Overload, TC = +25°C
5
Short Circuit, TC = +25°C
I
OUT
= 2000mA (main)
I
OUT
=
±208mA
(±12V)
I
OUT
=
±167mA
(±15V)
1
2,3
1
2,3
1,2,3
1,2,3
1,2,3
1,2,3
1,2,3
1,2,3
1,2,3
1,2,3
1,2,3
4.95
4.90
±
11.88
±11.76
0.0
0.0
5.05
5.10
±
12.12
±12.24
2000
±208
80
40
4.95
4.90
±
14.85
±14.70
0.0
0.0
5.05
5.10
±
15.15
±15.30
2000
±167
80
40
V
V
V
V
mA
mA
mVp-p
MVp-p
W
W
W
W
10
2.5
2.5
15
25
±
60
50
±60
10
2.5
2.5
15
25
±
75
50
±75
15
50
50
REGULATION
Line
1,3
Load
1,3
VR
LINE
VR
LOAD
mV
INPUT
Current
I
IN
1,2,3
1,2,3
1,2,3
15
50
50
mA
mA
mAp-p
Ripple Current
4
I
RIP
EFFICIENCY
E
FF
1
72
72
%
ISOLATION
Capacitive Load
6,7
Load Fault
Power Dissipation
3
Switching Frequency
1
ISO
C
L
1
100
100
MΩ
4
1
1
4
450
500
200
8.5
8.5
550
450
500
200
8.5
8.5
550
µF
W
P
D
F
S
KHz
For Notes to Specifications, refer to page 5
4
www.irf.com
AHV28XX Series
Specifications (Triple Output Models) - continued
Condition
-55°C
≤
T
C
≤
+125°C,
V
IN
= 28 V
DC
±5%,
C
L
=0,
unless otherwise specified
Group A
Subgroups
AHV2812T
Min
Max
AHV2815T
Min
Max
Units
TEST
DYNAMIC
CHARACTERISTICS
Step Load Changes
9
Output Transient
Recovery
9,10
SYMBOL
VOT
LOAD
TT
LOAD
50% Load
135
100% Load
No Load
135
50%
50% Load
135
100%
No Load
335
50% Load
50% Load
335
No lLoad
Input step 16 to 40 VDC
Input step 40 to 16 VDC
Input step 16 to 40 VDC
Input step 40 to 16 VDC
I
OUT
= o and
±625mA
I
OUT
= o and
±
625mA
4
4
4
4
4
4
4
4
4
4
4
4
-300
-400
+300
+400
100
2000
5.0
1200
-1500
4.0
4.0
750
15
15
-300
-400
+300
+400
100
2000
5.0
1200
-1500
4.0
4.0
750
15
15
mVpk
mVpk
µs
µs
ms
mVpk
mVpk
µ
s
µs
mVpk
ms
ms
Step Line Changes
Output Transient
Recovery
7,10, 11
VOT
LINE
TT
LINE
TURN-ON
Overshoot
1
1,12
Delay
7
Load Fault Recovery
VTon
OS
T on D
TR
LF
Notes to Specifications (Triple Output Models)
Tested at each output.
Parameter guaranteed by line and load regulation tests.
At least 25% of the total power should be taken from the (+5V) main output.
Bandwidth guaranteed by design. Tested for 20KHz to 2MHz.
An overload is that condition with a load in excess of the rated load but less than that necessary to trigger the short circuit
protection and is the condition of maximum power dissipation.
6. Capacitive load may be any value from 0 to the maximum limit without affecting dc performance. A capacitive load in excess of the
maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry, appearing as a
short circuit during turn-on.
7. Parameter shall be tested as part of design characterization and after design or process changes. Thereafter parameters shall be
guaranteed to the limits specified.
8. Above 125°C case temperature, derate output power linearly to 0 at 135°C case.
9. Load step transition time between 2
µs
and 10
µs
.
10. Recovery time is measured from the initiation of the transient to where V
OUT
has returned to within
±1%
of V
OUT
at 50% load.
11. Input step transition time between 2
µs
and 10
µs
.
12. Turn on delay time measurement is for either a step application of power at input or the removal of a ground signal from the inhibit
pin (pin 8) while power is applied to the input.
1.
2.
3.
4.
5.
Notes to Specifications (Dual Output Models)
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
Tested at each output.
Parameter guaranteed by line and load regulation tests.
Bandwidth guaranteed by design. Tested for 20KHz to 2MHz.
Total power at both outputs.
When operating with unbalanced loads, at least 25% of the load must be on the positive output to maintain regulation.
Capacitive load may be any value from 0 to the maximum limit without affecting dc performance. A capacitive load in excess of the
maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry, appearing as a
short circuit during turn-on.
Parameter shall be tested as part of design characterization and after design or process changes. Thereafter parameters shall be
guaranteed to the limits specified.
An overload is that condition with a load in excess of the rated load but less than that necessary to trigger the short circuit
protection and is the condition of maximum power dissipation.
Load step transition time between 2
µs
and 10
µs
.
Recovery time is measured from the initiation of the transient to where V
OUT
has returned to within
±1%
of V
OUT
at 50% load.
Input step transition time between 2
µs
and 10
µs
.
Turn on delay time measurement is for either a step application of power at input or the removal of a ground signal from the inhibit
pin (pin 2) while power is applied to the input.
Above 125°C case temperature, derate output power linearly to 0 at 135°C.
I wonder if you have any relevant information to provide: I would like to know the following information: (1) What are the mainstream MCU manufacturers in the market? (2) Which manufacturers and what ...
Dear leaders and experts: Hello! Thank you for taking the time out of your busy schedule to accept our questionnaire survey. In order to do a good job in the construction of electronic information sci...
We have been adjusting this BSP for more than a month, but there is no progress. We are very depressed! We bought a target board of mPC860, which comes with a BSP. We also made an MPC862 one ourselves...
Everyone, I am working on a project and need your participation if you have experience: (1) USB driver development. (2) Ordinary telephone hardware. (3) Location: Shanghai. Experience is required. Sal...
In most cases, the switched-mode power supply (SMPS) feedback loop regulates by observing the voltage at a specific point, while the remaining output voltage relies on the performance of the transform...
The previous beaglebone pin configuration file was in /sys/kernel/debug/omap_mux, which can be easily configured. Where is the current BB Black pin configuration file? How to configure it? Please answ...
1 Introduction
A wide variety of communication cables and control cables are widely used in various instruments and control equipment. Whether the cable is well-conducted and
whether
th...[Details]
China's new energy vehicles are in a transition period from research and development to real industrial development. In 2012, with the intensive launch of new energy vehicle policy planning, the de...[Details]
Introduction
Power subsystems are becoming more and more integrated into the overall system. Power systems have moved from being separate "essential dangerous devices" to being monitorable...[Details]
1 Introduction
As an emerging microfabrication technology, micro-electromechanical system (MEMS) technology has begun to be applied in various fields. It can integrate functions such as inform...[Details]
MediaTek (2454) announced the acquisition of F-MStar (3697) and attracted the attention of IC design industry. This morning, Gartner Semiconductor Industry Research Director Hong Cenwei analyzed ...[Details]
1 Introduction
In recent years, there have been many major advances in the production technology and processes of automotive headlights, which have greatly improved the performance of automoti...[Details]
Flooded Batteries
This battery developed in Germany can be used to power flashlights, strobe lights and toys as long as it is filled with water. This battery can be stored for 50 years and can...[Details]
Different initialization between C8051F and 80C51 series microcontrollers
In the past 30 years, major electronic component manufacturers in the world have launched their own unique single-chip...[Details]
Introduction
Liquid crystal, as a display device, is widely used in low-power products such as instruments, meters, and electronic equipment with its unique advantages. In the past, the displ...[Details]
1. Disadvantages of choosing too high a voltage level
Choosing too high a voltage level will result in too high an investment and a long payback period. As the voltage level increases, the...[Details]
LED lighting: Basic circuit design can be completed in as little as one day
Semiconductor manufacturers are also getting involved in the LED lighting business. The power circuit of LED req...[Details]
Introduction
X1226 has the functions of clock and calendar. The clock relies on hour, minute and second registers to track, and the calendar relies on date, week, month and year registers to tr...[Details]
The ARINC429 bus is one of the most commonly used communication buses between various subsystems of avionics. As the "skeleton" of modern avionics systems, once the bus system or the attached airbo...[Details]
Fruit planting is an important part of China's agricultural development, and fruit tree pest control operations are becoming more and more important. At present, the overall level of pesticide applica...[Details]
1 Embedded Systems
Embedded System refers to a collection of computer hardware and software with specific functions or purposes, which is divided into embedded software system and embe...[Details]