EEWORLDEEWORLDEEWORLD

Part Number

Search

10VS1

Description
120 V, 50/60 HZ, SINGLE PHASE EMI FILTER
CategoryPassive components   
File Size218KB,3 Pages
ManufacturerMACOM
Websitehttp://www.macom.com
Download Datasheet Parametric Compare View All

10VS1 Online Shopping

Suppliers Part Number Price MOQ In stock  
10VS1 - - View Buy Now

10VS1 Overview

120 V, 50/60 HZ, SINGLE PHASE EMI FILTER

10VS1 Parametric

Parameter NameAttribute value
minimum frequency0.1500 MHz
maximum frequency2 MHz
stateTransferred
filter typeSINGLE PHASE EMI FILTER
valsUL; CSA; VDE
high capacity2250 V
Minimum insertion loss frequency15 dB
Maximum insertion loss frequency40 dB
Maximum leakage current0.4000 mA
Manufacturer SeriesS
Installation typePANEL MOUNT
erating_frequency__hz_50/60
DimensionsL84.8XB52.8XH38.9 (mm)/L3.34XB2.08XH1.53 (inch)
Rated current10 A
Rated voltage120 V
heigh38.9 mm
length84.8 mm
width__mm_52.8
dditional_feature1/4 INCH QUICK CONNECT TERMINAL
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
Multipurpose Power Line RFI Filter for Emission Control
S Series
UL Recognized
CSA Certified
VDE Approved
20VS1
3VS1
S Series
• Combines Line to Ground interference rejection
filters with additional circuitry to reduce Line to
Line noise and transients
• Designed for use when equipment impedance at
RF frequencies is high
• Effective for use with switch-mode power supplies
• Effective when used to control emissions in
equipment using SCR and T2L circuits for
compliance with FCC Part 15, Subpart J and
EN55022, Level A, down to 150kHz
Specifications
Maximum leakage current each Line to Ground:
3 & 20A
60A
@120 VAC 60 Hz:
.4 mA
.75 mA
@250 VAC 50 Hz:
.7 mA
1.25 mA
Hipot rating (one minute):
Line to Ground:
Line to Line:
Rated Voltage (max):
Operating Frequency:
Rated Current:
2250 VDC
1450 VDC
250 VAC
50/60 Hz
3 to 60A
Ordering Information
20 V S 6
Input / Output Style
1 – .250 [6.3] spade terminals
6 – Threaded bolt
S Series
Leakage current designation
V – Standard
Operating Ambient Temperature Range
(at rated current Ir):
-10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir
(85-Ta)/45
Electrical Schematics
3, 6, 10VS
LINE
LOAD
20VS
Current Rating
3, 6, 10, 20 or 60A
LINE
LOAD
Available Part Numbers
3VS1
6VS1
10VS1
20VS1
20VS6
60VS6
60VS
LINE
LOAD
68
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com

10VS1 Related Products

10VS1 3VS1 20VS1 20VS6 60VS6 6VS1
Description 120 V, 50/60 HZ, SINGLE PHASE EMI FILTER 120 V, 50/60 HZ, SINGLE PHASE EMI FILTER 120 V, 50/60 HZ, SINGLE PHASE EMI FILTER 120 V, 50/60 HZ, SINGLE PHASE EMI FILTER 120 V, 50/60 HZ, SINGLE PHASE EMI FILTER 120 V, 50/60 HZ, SINGLE PHASE EMI FILTER
state Transferred ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE
filter type SINGLE PHASE EMI FILTER SINGLE PHASE EMI FILTER SINGLE PHASE EMI FILTER SINGLE PHASE EMI FILTER SINGLE PHASE EMI FILTER SINGLE PHASE EMI FILTER
high capacity 2250 V 2250 V 2250 V 2250 V 2250 V 2250 V
Minimum insertion loss frequency 15 dB 15 dB 15 dB 15 dB 15 dB 15 dB
Maximum insertion loss frequency 40 dB 40 dB 40 dB 40 dB 40 dB 40 dB
Maximum leakage current 0.4000 mA 0.4000 mA 0.4000 mA 0.4000 mA 0.4000 mA 0.4000 mA
Manufacturer Series S S S S S S
Installation type PANEL MOUNT PANEL MOUNT PANEL MOUNT PANEL MOUNT PANEL MOUNT PANEL MOUNT
Dimensions L84.8XB52.8XH38.9 (mm)/L3.34XB2.08XH1.53 (inch) L70.6XB46.2XH29.5 (mm)/L2.78XB1.82XH1.16 (inch) L70.6XB46.2XH29.5 (mm)/L2.78XB1.82XH1.16 (inch) L70.6XB46.2XH29.5 (mm)/L2.78XB1.82XH1.16 (inch) L70.6XB46.2XH29.5 (mm)/L2.78XB1.82XH1.16 (inch) L70.6XB46.2XH29.5 (mm)/L2.78XB1.82XH1.16 (inch)
Rated current 10 A 3 A 3 A 3 A 3 A 3 A
Rated voltage 120 V 120 V 120 V 120 V 120 V 120 V
working frequency - 50/60 HZ 50/60 HZ 50/60 HZ 50/60 HZ 50/60 HZ
Looking for part-time electronic technology developers
I have a small project to collect weak electrical signals from the human body, amplify and filter interference signals, and analyze and feedback the collected signals. If you have experience in this a...
benin Recruitment
Has anyone used the SQL Server database in WINCE Lite?
As the title says. If you have used it, what do you think? Is it necessary to use it? Do you have any suggestions?...
haitao664 Embedded System
Looking for VIA VT6435 card reader and driver!!
Looking for VIA VT6435 card reader and driver!!...
fangfang Embedded System
LMFlashProgrammer Software
Where is the JLINK that comes with the LMFlashProgrammer software?...
jiasen Microcontroller MCU
I found a board to practice on, welcome everyone to criticize.
[i=s]This post was last edited by chen468859 on 2017-4-26 13:55[/i] The uploaded Practice is my own drawing, and the other one is the original file. I searched for a chip and guessed it should be used...
chen468859 PCB Design
The principle and usage of A-law and U-law expansion
Can anyone tell me the principle and usage of A-law and U-law expansion? Thank you....
pingguo Integrated technical exchanges

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 364  1988  1801  882  563  8  41  37  18  12 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号