EEWORLDEEWORLDEEWORLD

Part Number

Search

3199DF124M016AXA1

Description
Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 16V, 20% +Tol, 20% -Tol, 120000uF, Stud Mount, CAN, ROHS COMPLIANT
CategoryPassive components    capacitor   
File Size88KB,7 Pages
ManufacturerCDE [ CORNELL DUBILIER ELECTRONICS ]
Environmental Compliance  
Download Datasheet Parametric View All

3199DF124M016AXA1 Overview

Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 16V, 20% +Tol, 20% -Tol, 120000uF, Stud Mount, CAN, ROHS COMPLIANT

3199DF124M016AXA1 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
package instruction,
Reach Compliance Codecompliant
ECCN codeEAR99
capacitance120000 µF
Capacitor typeALUMINUM ELECTROLYTIC CAPACITOR
diameter44.5 mm
dielectric materialsALUMINUM (WET)
ESR5.8 mΩ
length117.5 mm
Manufacturer's serial number3199
Installation featuresSTUD MOUNT
negative tolerance20%
Number of terminals2
Maximum operating temperature85 °C
Minimum operating temperature-55 °C
Package shapeCYLINDRICAL PACKAGE
Package formScrew Ends
polarityPOLARIZED
positive tolerance20%
Rated (DC) voltage (URdc)16 V
ripple current16200 mA
series3199
surface mountNO
Terminal pitch19.1 mm
Terminal shapeBINDING POST
Type 3199 Aluminum Electrolytic, Screw Terminals
Screw Terminal Capacitors for Power Output Filtering
With twice the capacitance of Type 3191 capacitor, Type 3199
extends output filtering performance into higher power,
especially with cold temperature requirements. Standard
encasement is with the capacitor element compressed onto
an aluminum peg in the can bottom and a phenolic peg in
the top. Optional Rilled construction is available. With rilled
construction the element is secured by rills, spoon shaped
dimples in the side of the can. Rilled construction offers
the industries highest vibration and shock withstanding
capability and excellent heat transfer.
Highlights
- Stud mount available
- High current application
- Industrial applications
- Smoothing and filtering
- Audio power supplies
–55 ºC to +85 ºC
7.5 Vdc to 75 Vdc
3900 µF to 1.2 F
–10% +30%
–10% +50%
≤6√CV µA (6 mA max.) at 5 minutes
Ambient Temperature
45 °C
2.24
Frequency
60 Hz 120 Hz
16 – 100 V
Low Temperature Characteristics
0.90
1.00
300 Hz
1.05
1000 Hz
1.10
≥10
kHz
1.15
55 °C
2.00
65 °C
1.73
75 °C
1.41
85 °C
1.00
Specifications
Temperature Range
Rated Voltage Range
Capacitance Range
Capacitance Tolerance
Leakage Current
Ripple Current Multipliers
Impedance ratio: Z
–20⁰C
∕ Z
+25⁰C
≤ 8 (16–50 Vdc)
≤ 4 (63–75Vdc)
Endurance, 5000 h at rated voltage and 85 ºC
Δ Capacitance: ±10%
ESR ≤ 200% of limit
DCL ≤ 100% of limit
Storage, 500 h at 85 ºC
Δ Capacitance: ±10%
ESR ≤ 175% of limit
DCL ≤ 200% of limit
10 to 500 Hz, 0.75 mm or 10 g* if less, 3 directions, 2 h ea
Δ Capacitance: ±5%
no visible damage or leakage
*15 g if rilled construction
RoHS Compliant
Endurance Life Test
Shelf Life Test
Vibration
CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800
Considerations for selecting sensors in humidity measurement
[font=宋体][size=10.5pt]Abstract: This paper discusses the necessity of correct humidity measurement, compares some commonly used humidity measurement methods, and analyzes various factors that affect t...
LUKEBS Test/Measurement
About PROTEUS, in PROTEUS, ".HEX" files are generated by assembly language.
I have been using PROTEUS recently. But if I use PROTEUS itself to compile "ASM" files, why does it always say that it cannot generate ".OBJ" files? I use an AVR microcontroller. The software should b...
sdaac Embedded System
Problems with installing msp430 gcc under Win7
After installing msp430 gcc, I clicked into the program and found that it was empty. What's the situation? Thank you....
zzplcch Microcontroller MCU
Some Discussion on RF Receiver Noise
System designers are always looking for simple solutions to complex system designs. Let’s look at RF front-end receiver solutions in the defense, aerospace, and 5G wireless infrastructure space. This ...
石榴姐 RF/Wirelessly
How to read data from the data bus of DSP2812
HelpHardware: DSP2812, external IO signals are connected to data bus XD0~XD7 through CPLD, the decoder chip select signal of CPLD is XZCS2, and the decoder is connected to address bus XA0, XA1, XA2,I ...
zhenghuaqwe Microcontroller MCU
Protel99se Access violation occurs when copper is laid
[font=Impact][size=4]How to solve the Access violation when protel99se is laying copper?[/size][/font]...
zttian PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 405  2430  154  1346  1086  9  49  4  28  22 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号