UNISONIC TECHNOLOGIES CO., LTD
GS1010FL
Preliminary
DIODE
SURFACE MOUNT GENERAL
RECTIFIER
DESCRIPTION
SOD-123F
The UTC
GS1010FL
is a surface mount general rectifier, it uses
UTC’s advanced technology to provide the customers with low profile
package and low leakage current, etc.
The UTC
GS1010FL
is suitable for ESD protection and surface
mounted applications, etc.
FEATURES
* Low profile package
* ESD protection
* Low leakage current
SYMBOL
ORDERING INFORMATION
Package
SOD-123F
Pin Assignment
1
2
K
A
Packing
Tape Reel
Ordering Number
Lead Free
Halogen Free
GS1010FLK-CA2F-R
GS1010FLG-CA2F-R
Note: Pin Assignment: A: Anode, K: Cathode
MARKING INFORMATION
PACKAGE
MARKING
SOD-123F
www.unisonic.com.tw
Copyright © 2014 Unisonic Technologies Co., Ltd
1 of 3
VER.a
GS1010FL
Preliminary
DIODE
ABSOLUTE MAXIMUM RATINGS
(T
A
=25°C, unless otherwise specified)
PARAMETER
SYMBOL
RATINGS
UNIT
Repetitive Peak Reverse Voltage
V
RRM
1000
V
Maximum RMS Voltage
V
RMS
700
V
Maximum DC Blocking Voltage
V
DC
1000
V
Rectified Current (Average) Half Wave Rectification with
I
O
1.0
A
Resist. Load at T
A
=25°C (Note 1)
Surge Forward Current at t<1s, T
J
=25°C
I
FSM
30
A
Junction Temperature
T
J
-55~+150
°C
Storage Temperature
T
STG
-55~+150
°C
Notes: 1. Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Absolute maximum ratings are stress ratings only and functional device operation is not implied.
2. Measured at 1MHz and applied reverse voltage of 0V D.C.
THERMAL DATA
PARAMETER
SYMBOL
θ
JA
RATINGS
200
UNIT
°C/W
Junction to Ambient
ELECTRICAL CHARACTERISTICS
(T
A
=25°C, unless otherwise specified)
SYMBOL
V
F
I
R
TEST CONDITIONS
I
F
=1.0A
V
R
=1000V, T
J
=25°C
V
R
=1000V, T
J
=100°C
MIN
TYP MAX UNIT
1.1
V
10
μA
50
μA
4.0
pF
PARAMETER
Forward Voltage
Leakage Current
Junction Capacitance (Note)
C
J
Note: Measured at 1MHz and applied reverse voltage of 4.0V D.C.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
2 of 3
VER.a
GS1010FL
Preliminary
DIODE
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
3 of 3
VER.a