EEWORLDEEWORLDEEWORLD

Part Number

Search

2430-46-G-BC-ST

Description
Silicon Surge Protector
CategoryAnalog mixed-signal IC    Trigger device   
File Size210KB,2 Pages
ManufacturerBourns
Websitehttp://www.bourns.com
Download Datasheet Parametric View All

2430-46-G-BC-ST Overview

Silicon Surge Protector

2430-46-G-BC-ST Parametric

Parameter NameAttribute value
Reach Compliance Codeunknow
ECCN codeEAR99
Certification statusNot Qualified
Trigger device typeSILICON SURGE PROTECTOR
Base Number Matches1
Features
Patented (MSP
®
) Multi-Stage Protection
Self-resetting low resistance sneak current
protection with Bourns
®
PPTC resistors
Patented Switch-Grade Fail-Short device
Quick response and high energy handling
UL
UL
Listing per UL497 (File E53117)
Telcordia GR-974 Analyzed, DA-1547
Volumes 1 and 2
®
Meets test requirements of GR 974,
GR 1361, SBC SR 5165 and RUS PE-80
Ideal for high-speed networks in high-
exposure environments
Sealed option for harsh environments
Solid brass, gold-plated pins
Test point access option
2430 Series 5-Pin Surge Protector
Bourns
®
5-pin Model 2430 is a new generation of Bourns
®
telecommunications protectors for superior performance and long life. The
2430 series protector provide highly reliable overvoltage and self-resetting sneak current protection for copper pair voice-band and
high speed data circuits. The Bourns
®
MSP
®
device combines the advantages of gas tube and solid state protection, while integrating
three advanced technologies: a proprietary high-effiency gas discharge tube, precision matched metal oxide varistors and a patented
Switch-Grade Fail-Short mechanism. The unique Switch-Grade Fail-Short mechanism ensures superior thermal protection with fast
acting, highly reliable response to thermal overload conditions. This combined technology provides lower capacitance, higher reliability
and longer life than competitive hybrid technologies. Bourns
®
Multifuse
®
PPTCs are used for sneak current protection providing reliable
and self-resetting performance with less than four ohms of resistance.
Bourns
®
2430 protectors can be used universally for broadband voice and data circuits including ADSL, ADSL2+, VDSL, VDSL2 and
high-speed Ethernet. The 2430 series is an innovative, superior choice for 5 pin protection of copper pair circuits.
Characteristics
Test methods per UL 497, CSA C22.2, Telcordia GR 974, 1361 and SBC SR 5165.
DC Breakdown ............................................................................................................................................300-400 V
AC Breakdown @ 60 Hz ..............................................................................................................................300-400 V
Impulse Breakdown
100 V/µs ................................................................................................................................................600 V
1000 V/µs ..............................................................................................................................................650 V
Insulation Resistance @ 100 Vdc ................................................................................................................> 1 GΩ
Insertion Loss @ 100 MHz...........................................................................................................................< 0.4 dB
1
Return Loss @ 100 MHz..............................................................................................................................< 14 dB
1
Capacitance Tip to Ring @ 1 MHz ..............................................................................................................12 pF typical
Capacitance Tip or Ring to Ground @ 1 MHz .............................................................................................23 pF typical
Impulse Reset
2
52 V, 260 mA ........................................................................................................................................< 10 ms
135 V, 200 mA .......................................................................................................................................< 10 ms
150 V, 200 mA .......................................................................................................................................< 150 ms
Impulse Life Characteristics (Tip and Ring to Ground Simultaneously)
10 A, 10/1000 µs ...................................................................................................................................> 3000 operations
100 A, 10/1000 µs .................................................................................................................................> 300 operations
300 A, 10/1000 µs .................................................................................................................................> 100 operations
500 A, 10/1000 µs .................................................................................................................................> 400 operations
3
2,000 A, 10/250 µs ...............................................................................................................................> 25 operations
5,000 A, 20/100 µs ................................................................................................................................> 2 operations
20,000 A, 8/20 µs .................................................................................................................................> 1 operation
AC Life Characteristics (Tip and Ring to Ground Simultaneously)
0.5 A rms continuous ............................................................................................................................> 30 seconds
1 A rms, 1 second, 600 ft. cable ...........................................................................................................> 60 operations
1 A rms, 1 second, 1 mile cable............................................................................................................> 60 operations
10 A rms, 1 second ...............................................................................................................................> 5 operations
65 A rms, 11 cycles...............................................................................................................................> 1 operation
3
120 A rms, 0.1 second ..........................................................................................................................1 operation
High Current Capability and Thermal Operation (T/R to Ground) ...............................................................> 30 Arms, simultaneously
Storage and Operating Temperature ..........................................................................................................-55 to +85 °C
Sneak Current Characteristics
Resistance (No Heat Coil Inductance) ..................................................................................................< 4 ohms
Transition Current @-40 °C (800 mA), +20 ° C (540 mA), +65 °C (300 mA).................................................< 210 seconds
Rated Current @-40 °C (100 mA), +20 ° C (100 mA), +65 °C (100 mA) ......................................................> 3 hours
Impulse Life 10 x 1000
µs
@-40 °C, +20 ° C, +65 °C..................................................................................25 A ELTGS
Telcordia analyzed for controlled (non-sealed) and uncontrolled high exposure (sealed) environments per GR 974 and SBC SR 5165.
Please refer to Telcordia Analysis Report DA-1547 Volumes 1 and 2.
Notes:
1
Tested according to Category 5 requirements
2
Network applied
3
Per Rus PE 80
Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
[Me and WEBENCH] TPS54360 step-down 24V to 15V/3A on-board testing and problem solving under the guidance of WEBENCH
[i=s] This post was last edited by Diguapatch on 2014-1-15 15:12 [/i] [I. Requirements Analysis] Recently, there is a project that needs to convert DC24V to DC15V, and requires a maximum peak load cap...
地瓜patch Analogue and Mixed Signal
Normalization processing problem in HVPM_Sensorless_2833x
I would like to ask everyone, how is the normalization processing done in HVPM_Sensorless_2833x, for example, voltage, current, frequency, _iq VqTesting = _IQ(0.15) in the program; then what is the vo...
XZZ Microcontroller MCU
pic development board with wireless transceiver module
I am currently working on a PIC-based wireless dimming system for my home. If anyone knows how to do this, please get in touch. Thanks for your advice!...
淡蓝晓鱼 Microchip MCU
Problems when writing CEC files
When writing a stream interface driver, after writing the entry function, driver code, and registry, you need to write a CEC file. In this process, how can you add a "Feature" that includes two action...
yb2004 Embedded System
How to set up the AD9779A interpolation filter?
How to use AD9779A to convert a 25M sine wave input signal into a 175M sine wave output signal?...
eeleader FPGA/CPLD
A newbie needs help. . Experts, please come in and teach me quickly. . . I bow down to you.
library ieee;use ieee.std_logic_arith.all;use ieee.std_logic_1164.all;use ieee.std_logic_unsigned.all;---------------------------------entity signal_gen isport(clk:in std_logic; outp:out std_logic);en...
wangpiaoke FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1009  331  266  1766  2520  21  7  6  36  51 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号