EEWORLDEEWORLDEEWORLD

Part Number

Search

380947_15

Description
Mini DC/AC Clamp Meters
File Size228KB,1 Pages
ManufacturerExtech
Websitehttp://www.extech.com/
Download Datasheet View All

380947_15 Overview

Mini DC/AC Clamp Meters

Mini DC/AC Clamp Meters
Ideal for low current measurements
Extech’s Mini Clamp Meters, with their high resolution, are the ideal tools for
accurately measuring very low AC & DC currents. Smaller in size than traditional
clamp meters, they easily fit into tight spaces.
Features:
Three models provide high Accuracy and Resolution
Large 4000 count LCD display with full function indication
Fast 40 segment analog bargraph
One touch "Auto Zero" for DCA measurements eliminates
the need to turn a knob to zero adjust
Measure current draw when conducting energy usage audits
Data hold, Max/Min recall display
0.9" (23mm) clamp jaw opening
Overload protection to 400A DC
True RMS models recommended for measurements
where distortion may otherwise cause inaccuracies
Optional 3-prong AC Line Separator enables safe
and easy measurements on power cables with
molded plugs (splits hot conductor from neutral
and ground)
380947
380941
380942
Specifications
True RMS
AC Current:
Resolution
Accuracy
DC Current:
Resolution
Accuracy
AC Voltage:
Resolution
Accuracy
DC Voltage:
Resolution
Accuracy
Resistance:
Resolution
Accuracy
Frequency:
Resolution
Accuracy
Dimensions:
Weight:
380942
True RMS
30A
0.1mA
±(2.0%+5d)@50/60Hz
30A
1mA
400V
0.1V
±(2.0%+5d)
400V
0.1V
±(1.0%+2d)
7.2x2.5x1.4" (183x64x36mm)
6.2 oz (190g)
380941
200A
100mA
±(1.0% +2d)
40A
10mA
±(1.0% +2d)
400V
0.1V
±(1.5% +4d) (50/60Hz)
400V
0.1V
±(1.0% +2d)
400Ω
0.1Ω
±(1.5% +2d)
10kHz
0.01Hz
±(0.5% +2d)
7x1.75x1.25" (178x45x32mm)
6 oz (170g)
380947
True RMS
4A/40A/100A/400A
1mA/10mA/100mA/100mA
±(1.5% +3d)
40A/400A
10mA/100mA
±(1.0% +2d)
10kHz
0.01Hz
±(0.5% +2d)
7.2x2.5x1.4" (183x64x36mm)
6.2 oz (190g)
Ordering Information
380942..............True
RMS 30A Mini Clamp Meter
380942-NIST
....380942 with Certificate of Calibration Traceable to NIST
380941..............200
Amp DC/AC Mini Clamp DMM
380941-NIST
....380941 with Certificate of Calibration Traceable to NIST
380947..............True
RMS DC/AC Mini Clamp Meter
380947-NIST
....380947 with Certificate of Calibration Traceable to NIST
Accessories
480172..............AC
Line Separator - 3 prong
www.extech.com
Specifications subject to change without notice.
1/26/12 - R1
Copyright © 2007-2011 Extech Instruments Corporation. All rights reserved including the right of reproduction in whole or in part in any form.
Several issues in WinCE BSP development, urgent!!!
I am from Qingdao. I used to be engaged in application development. I want to switch to WinCE BSP development. Now I have quit my job and stay at home to concentrate on learning WinCE BSP development....
ThankGod Embedded System
Help!! avrETH1 compilation error
It is the error message above!! Please help me explain it. I will also send the source code. I am a novice, please write it in more detail. Thank you...
efjerry Microchip MCU
Question: The reboot command in the vxworks program does not work, what is the reason?
I started a network download task, and after the download was completed, I executed reboot (BOOT_CLEAR). I stepped through the debugging to this step, but the target machine just didn't reboot. Why? S...
lslsino Real-time operating system RTOS
The problem of joint debugging of proteus and keil...
I have just started to learn how to use proteus to make a simple light-on circuit, but when I use KEIL to debug it, I always can't connect it... What is the reason? I have just started to use proteus,...
greenmilan Embedded System
Eclipse Manual
Does anyone have documentation on using Elicpse? :time:...
cactus3721 RF/Wirelessly
The fantasy of 500W...
I can quit my job immediately or leave directly, and then go to receive the award quietly alone or with my family. I will have a car worth 200,000 yuan and the key to a 120-square-meter house soon. I ...
gh131413 Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1685  621  2540  1626  108  34  13  52  33  3 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号