Miniature Relay PT
File Size620KB,4 Pages
ManufacturerMACOM
Websitehttp://www.macom.com
Download Datasheet View All

PT78702 Overview

Miniature Relay PT

General Purpose Relays
Industrial Relays
Miniature Relay PT
n
n
n
n
n
n
n
SCHRACK
2 pole 12A, 3 pole 10A or 4 pole 6A, 2, 3 or 4 form C (CO) contacts
DC or AC coil
Switching performance up to 3000VA
Relay height 29mm
Mechanical indicator, optional LED and protection diode
Manual test tab, optionally lockable
White marking tabs
Typical applications
Universal use in control and automation
F0191-B
VZL
Approvals
VDE REG.-Nr. 115719, UL E214025, Lloyds 00/20059(E2)
Technical data of approved types on request
Contact Data
(continued)
Contact ratings
Type Contact
UL 508
PT 2 C (CO)
PT 2 C (CO)
PT 2 A (NO) of C (CO)
PT 2 A (NO) of C (CO)
PT 3 C (CO)
PT 3 C (CO)
PT 3 A (NO) of C (CO)
PT 3 B (NC) of C (CO)
PT 5 C (CO)
PT 5 C (CO)
PT 5 A (NO) of C (CO)
PT 5 B (NC) of C (CO)
EN60947-4-1
PT 2 A (NO) of C (CO)
PT 2 A (NO) of C (CO)
PT 3
PT 3
PT 5
PT 5
A (NO) of C (CO)
A (NO) of C (CO)
A (NO) of C (CO)
A (NO) of C (CO)
Load
12A, 250VAC, general purpose, 70°C
12A, 250VAC, resistive, 70°C
12A, 250VAC, resistive, 70°C
12A, 250VAC, resistive, 70°C
10A, 250VAC, general purpose, 70°C
10A, 250VAC, resistive, 70°C
10A, 250VAC, resistive, 70°C
10A, 250VAC, resistive, 70°C
6A, 250VAC, general purpose, 70°C
6A, 250VAC, resistive, 70°C
6A, 250VAC, resistive, 70°C
6A, 250VAC, resistive, 70°C
Cycles
6.000
100x10
3
100x10
3
100x10
3
6.000
100x10
3
100x10
3
100x10
3
6.000
100x10
3
100x10
3
100x10
3
Contact Data
3 form C
4 form C
3 CO
4 CO
Rated voltage
240VAC
Max. switching voltage
400VAC
400VAC
240VAC
Rated current
12A
10A
6A
Limiting making current, max. 20ms 24A
20A
12A
Limiting breaking current
12A
10A
6A
Limiting short-time current
300A/30ms
Switching power
3000VA
2500VA
1500VA
Contact material
AgNi90/10, AgNi90/10 gold plated
Min. recommended contact load
12V at 10mA
gold plated: 20mV at 1mA
Initial voltage drop
30mV at 100mA/6VDC
Frequency of operation
with/without load
360/36000h
-1
Operate time typ., DC coil
15ms
Release time typ., DC coil, without/with PD
10/18ms
Bounce time typ., DC coil, form A/form B
6/8ms
Contact ratings
Type
IEC 61810
PT 2 DC/AC coil
PT 2 DC/AC coil
PT 2 DC/AC coil
PT 3 DC/AC coil
PT 5 DC/AC coil
Contact
C (CO)
A (NO) of C (CO)
A (NO) of C (CO)
C (CO)
C (CO)
Load
12A, 250VAC, cosφ=1, 70°C
9A, 250VAC, cosφ=1, 80°C
4A, 250VAC, cosφ=1, 80°C
10A, 250VAC, cosφ=1, 70°C
6A, 250VAC, cosφ=1, 70°C
Cycles
70x10
3
150x10
3
300x10
3
100x10
3
100x10
3
Contact arrangement
2 form C
2 CO
PT2
PT3
PT5
Mechanical endurance
DC coil
AC coil
400VAC, 3.75A, AC3, opposite polarity, 70°C
230VAC, 1.7A, AC5b (400W lamp load),
opposite polarity, 70°C
250VAC, 2A, AC3, opposite polarity 70°C
230VAC, 1.7A, AC5b (400W lamp load),
opposite polarity, 70°C
250VAC, 3A, AC3, same polarity 70°C
230VAC, 1.7A, AC5b (400W lamp load),
same polarity, 70°C
30x10
6
operations
20x10
6
operations
Coil Data
Coil voltage range
Operative range, IEC 61810
DC coil, AC-coil 50Hz
AC coil 60 Hz at 70°C
Coil insulation system according UL
6 to 220VDC
6 to 230VAC
2
90..110% of rated voltage
class 155 (F)
04-2011, Rev. 0411
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1
[TI Recommendations] [Summary] JTAG module summary post (updated)
According to my suggestion, the posts are categorized as follows: JTAG module 1: Dear experts, I would like to ask a question about jtagWait() to prevent JTAG failure https://bbs.eeworld.com.cn/viewth...
cat3902982 Microcontroller MCU
Please tell me how to do embedded development under Linux
I want to learn about embedded development under Linux recently. There are some simple things I don't understand. I hope friends who work in this field or technical experts can give me some advice. Th...
rightnow10 Linux and Android
[Show samples] + Talk about the experience of applying for TI chips in recent years (I am a TI fan)
First, click on a certain component. Its related information will be displayed.Click on Sample and Purchase.Get SamplesClick to continue applying for samplesIn addition to the chip you just clicked, y...
youluo TI Technology Forum
Newbie help - load upper and lower limit alarm circuit design
I am a beginner, and I am not familiar with many things. Please give me some guidance. Circuit requirements: 1. When the load is less than 3 kilo-ohms or greater than 3.4 kilo-ohms, the upper and lowe...
liuhaohui814 MCU
A brief analysis of the working principle of the switch
[b]I. Overview[/b] Switching technology is a switching product with the characteristics of simplicity, low price, high performance and high port density, which reflects the complex switching technolog...
songbo Industrial Control Electronics
Embedded Systems Overview
Courseware materials suitable for beginners!...
gaoxiao Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1157  2437  2573  2320  617  24  50  52  47  13 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号