3
Power Supplies
Silver Line Series – Single & Multi-Output Linears
The Silver Line series follows the industry accepted
footprint for open frame, linear power supplies. Standard
screw terminal connections and optional covers are offered
for safety considerations.
Applications
• Industrial Control Circuits and Components
• Instrumentation
• Drives
• CNC Machinery
• Equipment for food industry
• Microprocessor Circuits
• Analog Circuits
• Noise sensitive Circuitry and Sensors
Features
• Easy-to-install screw terminal connections
• Cover options
• Industry standard footprint
• Universal input and approvals (115/230 Vac)
• Low noise, extremely quiet DC output. For noise
sensitive or analog circuitry.
• Fast transient response. Ideal for test applications.
• Built-in OVP on 5 V models and optional on
12, 15 and 24 V models
• Automatic resetting overload protection
• Short circuit protected
• Two year limited warranty
Certifications and Compliances
•
- UL 60950-1
CUL/CSA-C22.2
No. 234-M90
•
Certified, ITE
- CSA C22.2 CSA 60950-1
•
- IEC60950-1
Cover Option
Cooling
UL 60950
E137632
E137632
Specifications
Parameter
Condition
Input
Input Voltage
Input Frequency
Output
Line Regulation
Load Regulation
Ripple
DC Output
Adjustment Range
Overvoltage
Protection
Transient
Response Time
Overload
Protection
Remote Sensing
Available to compensate
for output voltage drop
on selected models.
General
Operating
Temperature Range
Storage
Temperature Range
Temperature
Coefficient (Typical)
Stability
After warm-up
Linear power supplies
have inherently low
conducted and radiate
noise levels
Derate to 40% at +70°C
0 to +50°C
-25°C to +85°C
0.01% 0°C
±.5%
For most system
applications they will
meet requirements of
FCC Class B and VDE
0871 for Class B
for 10% change
for 50% change
0.05%
0.05%
3.0 mV maximum
Peak-to-Peak
±5% Minimum
All 5-Volt outputs include
build-in OVP as standard
(setting is 6.2 V ±0.4 V)
OVP is optionally
available on other types
at 50% Load Changes
50 msec.
Automatic current
limit foldback
0.5 Vdc
100/120/220/230/240
Vac Selectable
47-63 Hz
Limit
Recognized Component, ITE
EMI/RFI
Derate power by an additional 15%
Forced air. 20 CFM required for full rating
Derate 30% without cooling
Specifications are typical. Load Regulation on outputs without Remote Sense, .1% typical.
144
Contact
Technical Services
at
(800) 377-4384
with any questions.
Visit our website at www.solahd.com.
Power Supplies
SL Series Selection Table
Dimensions - inches (mm)
3
Catalog Number
SLS-05-030-1T
SLS-05-060-1T
SLS-05-090-1T
SLS-05-120-1T
SLS-12-017T1
SLS-12-034T
SLS-12-051T
SLS-12-068T
SLS-15-045T
SLS-15-060T
SLS-24-012T
SLS-24-024T
SLS-24-036T
SLS-24-048T
SLS-24-072T
SLS-24-120T
SLD-12-1010-12T
1
SLD-12-1818-12T
1
SLD-12-3434-12T
SLD-15-3030-15T
SLD-12-6034-05T
SLD-12-3015-05T
SLT 12-20404-12T
1
SLT 12-31010-12T1
SLT 12-61818-12T1
Output 1
5V@3A*
2
5 V @ 6 A *
2
5 V @ 9 A *
2
5 V @ 12 A *
2
12 V @ 1.7 A
2
or
15 V @ 1.5 A
12 V @ 3.4 A
2
12 V @ 5.1 A
2
Output 2
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
2
Output 3
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
-12 V @ .4 A or
-15 V @ .4 A
-12 V @ 1 A
2
or -15 V @ .8 A
-12 V @ 1.8
A or -15 V @
1.5 A
Case
A
B1
C
I2
A
B1
C
I2
C
I2
A
B2
C
I2
K
L
H1
D
I3
I3
I1
C1
H2
F
G2
12 V @ 6.8 A
2
15 V @ 4.5 A
2
15 V @ 6 A
2
24 V @ 1.2 A v
24 V @ 2.4 A
2
24 V @ 3.6 A
2
Case A
24 V @ 4.8 A
2
24 V @ 7.2 A
2
24 V @ 12.0 A
12 V @ 1 A or
15 V @ .8 A
12 V @ 1.8 A or
15 V @ 1.5 A
12 V @ 3.4 A
2
15 V @ 3 A
2
–
-12 V @ 1 A or
-15 V @ .8
-12 V @ 1.8 A or
-15 V @ 1.5 A
-12 V @ 3.4 A
2
-15 V @ 3 A
2
5 V @ 6 A *
2
5 V @ 3 A *
2
5 V @ 2 A *
2
5 V @ 3 A *
2
5V @ 6A *
2
12 V @ 3.4 A
2
12 V@ 1.5 A
12 V @ .4 A or
15 V @ .4 A
12 V @ 1 A
2
or
15 V @ .8 A
12 V @1.8 A or
15 V @1.5 A
Over Voltage Protector (OVP)
SLO-12-000-1
SLO-12-000-TB
6.2 V to 34 V
Adjustable @ 8 A
6.2 V to 34 V
Adjustable @ 8 A
For Cases B through K
For Case A or Cases B through K
(when used with a cover)
J1
J2
Case B
Cover Options
Catalog
Number
SLCASA-CVR
SLCASB-CVR
SLCASC-CVR
Note:
Covers are sold separately. When used, derate the power supply by 15%
of its rated value.
Description
Cover for Case A
Cover for Case B
Cover for Case C
Notes:
*
With Built-In OVP
1. 12/15 Volt models are factory set for 12 Volt operation. 15 Volt operation
is field adjustable.
2. With Remote Sense (R.S.)
Catalog
Number
SLCASI-CVR
SLCASK-CVR
SLCASL-CVR
Description
Cover for Cases
I1, I2, & I3
Cover for Case K
Cover for Case L
Contact
Technical Services
at
(800) 377-4384
with any questions.
Visit our website at www.solahd.com.
145
Power Supplies
Silver Line Dimensions (inches/mm)
3
Case J1
Case J2
OVP (OPTIONAL)
AC INPUT/DC OUTPUT
13.98" (355)
.49" (12.5)
12.99" (330)
.49" (12.5)
1.250" (32)
.75" (19)
.59" (15)
MAX
4.87" (124)
4.125" (105)
V ADJ.
Cases I1, I2 and I3
Notes:
1.250" (32)
2.75" (70)
.49" (12.5)
.188" (4.8)
All dimensions in inches (mm). Dimensions may change and should not be
used for construction purposes.
Be sure to specify the complete part number when ordering. Orders may be
placed with your local SolaHD distributor.
°
MTG HOLES (12 PLACES)
4 2 31 5
AC Input
- OUT
-S
+S
+ OUT
WEIGHT: 7.5 LBS.
(3.4 KG)
PEM NUT HOLES
8-32 MTG (4 PLACES)
.75" (19)
Case K
AC INPUT/DC OUTPUT
16.85" (428)
. 375" (9.53)
15.98" (406)
WEIGHT: 19 LBS.
(8.55 KG)
2.52” (64)
. 55" (14)
4.92" (125)
4.13” ( 105)
V ADJ.
. 394" (10)
. 630 (16) Ma x.
OVP (OPTIONAL)
. 236”
°
MTG HOLES (16 PLACES)
(6.0)
1.34" (34)
2.52" (64)
5 1 3 24
AC Input
+ OUT
- OUT
-S
+S
3.46" (88)
. 39” (10)
Heat Sink
Case L
Contact
Technical Services
at
(800) 377-4384
with any questions.
Visit our website at www.solahd.com.
147
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Sola/Hevi-Duty
:
SLS-05-060-1T SLS-15-060T SLT-12-20404-12T SLS-05-120-1T SLO-12-000-1 SLO-12-000-TB SLS-24-012T
SLS-24-036T SLS-24-120T SLD-12-1010-12T SLS-15-045T SLS-24-072T SLS-24-048T SLS-12-034T SLD-12-
1818-12T SLS-12-051T SLD-12-3015-05T SLS-05-030-1T SLT-12-61818-12T SLS-05-090-1T SLD-15-3030-15T