Description
AC/DC Switching Power Supplies
File Size155KB,4 Pages
ManufacturerWall Industries,Inc.
Websitehttps://www.wallindustries.com/
Download Datasheet View All

PSSEU60-302 Overview

AC/DC Switching Power Supplies

Wall Industries, Inc.
Rev A
PSSEU60 SERIES
Up to 63 Watts, AC/DC Switching Power Supplies
FEATURES
Class I
Single to Quad Outputs
RoHS Compliant
Internal EMI Filter
Up to 63 Watts Output Power
100% Burn-in Tested
Wide Input Voltage Range: 90~264VAC, 47~63Hz
Output Voltage Available from 3VDC to 50VDC
Over Voltage Protection (Crowbar Design)
Input Surge Current, Over Voltage, and Over Load Protection
3-Pin Input Connector
2-Pin Input Connector Available (See PSSEU61 Series)
Meets FCC Part-15 Class B and CISPR-22 Class B Emission Limits
UL/cUL(UL 60950-1:2nd Edition) Safety Approvals
DESCRIPTION
The PSSEU60 series of Class I AC/DC switching mode power supplies provides up to 63 Watts of continuous output
power in a 5.43” x 3.43” x 1.76” enclosed package. This series has single, dual, triple, and quad output models with a
wide input voltage range of 90~264VAC. These power supplies have an internal EMI filter and are protected against
over load, over voltage, and input surge current conditions. This series also has UL/cUL (UL 60950-1: 2
nd
edition) safety
approvals and meets FCC Part-15 class B and CISPR-22 Class B emission limits. These units are well suited for use in
industrial equipment as well as many other applications. All models are 100% burn-in tested.
Size:
5.43 x 3.43 x 1.76 inches
138.0 x 87.0 x 44.6 mm
Weight:
1.1 lbs (500g)
TECHNICAL SPECIFICATIONS: PSSEU60 SERIES
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
INPUT SPECIFICATIONS
Input Voltage
Input Frequency
Input Current
Inrush Current
No Load Power Consumption
OUTPUT SPECIFICATIONS
Output Voltage
Line Regulation
Load Regulation
Output Power
Output Current
Ripple & Noise (peak to peak)
Hold-up Time
Start-up Time
Transient Response Time
Temperature Coefficient
PROTECTION
Over Voltage Protection
Over Current Protection
GENERAL SPECIFICATIONS
Efficiency
Dielectric Withstanding Voltage
Isolation Resistance
Leakage Current
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Cooling
MTBF
PHYSICAL SPECIFICATIONS
Weight
Dimensions (L x W x H)
Input Connector
Output Connector
SAFETY & EMC
Safety Approvals
EMI Requirements for CISPR-22
EMI Requirements for FCC PART-15
TEST CONDITIONS
Safety Approvals Input Voltage Range
Operating Input Voltage Range
100VAC, full load
240VAC, full load
115VAC, full load, 25°C, cold start
230VAC, full load, 25°C, cold start
230VAC, no load
Single Output Models
Dual, Triple, & Quad Output Models
Min
100
90
47
Typ
Max
240
264
63
Unit
VAC
Hz
A
1.6
1.0
33
65
5
5.5
See Table
A
W
LL to HL, full load
230VAC
0.5
3
See Table
1
7
63
2
1
%
%
W
%
ms
s
ms
%/°C
%
%
%
VDC
90VAC, full load
110VAC, full load
100VAC, full load
100VAC, Full load to half load
0~50°C
Outputs under 3.3VDC
Others
12
-0.04
112
110
2
4
+0.04
132
150
88
230VAC, full load
Primary to Secondary
Primary to PE
Test Voltage = 500VDC
240VAC/60Hz
Derating linearly from 100% Load at 25°C to 50% load at 70°C
70
4242
2506
50
0.75
0
-40
0
0
100,000
+70
+85
95
95
Free air convection
mA
°C
°C
%
%
hours
MIL-HDBK-217F, 25°C
1.1 lbs (500g)
5.43 x 3.43 x 1.76 inches (138.0 x 87.0 x 44.6 mm)
See mechanical drawing
See mechanical drawing
UL/cUL (UL 60950-1: 2
nd
edition)
220VAC
110VAC
B
B
Class
Class
12/19/2013
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797
website: www.wallindustries.com • e-mail: sales@wallindustries.com
Page 1 of 4
Anyone who has studied S3C6410 SPI driver please come in! ! Trouble!
I wrote a driver for A/D conversion, using SPI for communication. The code is already written, but I can't read the data! I mainly look at the mcpdrv_probe and mcp_read functions. Am I initializing th...
a8719978 Embedded System
PCB design software allegro16.6 demonstration area rule settings
In the previous issue, we set the physical rules and spacing rules. In this issue, Banermei will continue to introduce the regional constraint rule settings. When using PCB design tools to draw boards...
kdyhdl PCB Design
[EEWORLD module arrangement] +DS1302+DS18B20 module
[i=s] This post was last edited by paulhyde on 2014-9-15 03:37 [/i] DS1302+DS18B20 module...
nasdfg Electronics Design Contest
msp4304272 infoFlash data is garbled
The parameters stored in infoFlash are messed up. I don't know what's going on. Is there anyone who has encountered this problem? Please help me solve it. I'd be very grateful....
ligenbaichi Microcontroller MCU
Comparison table of printed words and real names on SMD transistors
Yesterday, when I was surfing the Internet, I found some information that I thought was very good. I would like to share it with you. If you think it is good, don’t let it sink....
zhuxl Analog electronics
ADC related knowledge
ADCs come in a variety of speeds, use different interface circuits, and provide different levels of accuracy. The most common types of ADCs include flash ADCs, successive approximation ADCs, and sigma...
KG5 Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2907  1882  1796  1337  787  59  38  37  27  16 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号