EEWORLDEEWORLDEEWORLD

Part Number

Search

PSSEU60-303

Description
AC/DC Switching Power Supplies
File Size155KB,4 Pages
ManufacturerWall Industries,Inc.
Websitehttps://www.wallindustries.com/
Download Datasheet View All

PSSEU60-303 Overview

AC/DC Switching Power Supplies

Wall Industries, Inc.
Rev A
PSSEU60 SERIES
Up to 63 Watts, AC/DC Switching Power Supplies
FEATURES
Class I
Single to Quad Outputs
RoHS Compliant
Internal EMI Filter
Up to 63 Watts Output Power
100% Burn-in Tested
Wide Input Voltage Range: 90~264VAC, 47~63Hz
Output Voltage Available from 3VDC to 50VDC
Over Voltage Protection (Crowbar Design)
Input Surge Current, Over Voltage, and Over Load Protection
3-Pin Input Connector
2-Pin Input Connector Available (See PSSEU61 Series)
Meets FCC Part-15 Class B and CISPR-22 Class B Emission Limits
UL/cUL(UL 60950-1:2nd Edition) Safety Approvals
DESCRIPTION
The PSSEU60 series of Class I AC/DC switching mode power supplies provides up to 63 Watts of continuous output
power in a 5.43” x 3.43” x 1.76” enclosed package. This series has single, dual, triple, and quad output models with a
wide input voltage range of 90~264VAC. These power supplies have an internal EMI filter and are protected against
over load, over voltage, and input surge current conditions. This series also has UL/cUL (UL 60950-1: 2
nd
edition) safety
approvals and meets FCC Part-15 class B and CISPR-22 Class B emission limits. These units are well suited for use in
industrial equipment as well as many other applications. All models are 100% burn-in tested.
Size:
5.43 x 3.43 x 1.76 inches
138.0 x 87.0 x 44.6 mm
Weight:
1.1 lbs (500g)
TECHNICAL SPECIFICATIONS: PSSEU60 SERIES
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
INPUT SPECIFICATIONS
Input Voltage
Input Frequency
Input Current
Inrush Current
No Load Power Consumption
OUTPUT SPECIFICATIONS
Output Voltage
Line Regulation
Load Regulation
Output Power
Output Current
Ripple & Noise (peak to peak)
Hold-up Time
Start-up Time
Transient Response Time
Temperature Coefficient
PROTECTION
Over Voltage Protection
Over Current Protection
GENERAL SPECIFICATIONS
Efficiency
Dielectric Withstanding Voltage
Isolation Resistance
Leakage Current
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Cooling
MTBF
PHYSICAL SPECIFICATIONS
Weight
Dimensions (L x W x H)
Input Connector
Output Connector
SAFETY & EMC
Safety Approvals
EMI Requirements for CISPR-22
EMI Requirements for FCC PART-15
TEST CONDITIONS
Safety Approvals Input Voltage Range
Operating Input Voltage Range
100VAC, full load
240VAC, full load
115VAC, full load, 25°C, cold start
230VAC, full load, 25°C, cold start
230VAC, no load
Single Output Models
Dual, Triple, & Quad Output Models
Min
100
90
47
Typ
Max
240
264
63
Unit
VAC
Hz
A
1.6
1.0
33
65
5
5.5
See Table
A
W
LL to HL, full load
230VAC
0.5
3
See Table
1
7
63
2
1
%
%
W
%
ms
s
ms
%/°C
%
%
%
VDC
90VAC, full load
110VAC, full load
100VAC, full load
100VAC, Full load to half load
0~50°C
Outputs under 3.3VDC
Others
12
-0.04
112
110
2
4
+0.04
132
150
88
230VAC, full load
Primary to Secondary
Primary to PE
Test Voltage = 500VDC
240VAC/60Hz
Derating linearly from 100% Load at 25°C to 50% load at 70°C
70
4242
2506
50
0.75
0
-40
0
0
100,000
+70
+85
95
95
Free air convection
mA
°C
°C
%
%
hours
MIL-HDBK-217F, 25°C
1.1 lbs (500g)
5.43 x 3.43 x 1.76 inches (138.0 x 87.0 x 44.6 mm)
See mechanical drawing
See mechanical drawing
UL/cUL (UL 60950-1: 2
nd
edition)
220VAC
110VAC
B
B
Class
Class
12/19/2013
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797
website: www.wallindustries.com • e-mail: sales@wallindustries.com
Page 1 of 4
EEWORLD University - Make the Internet of Things a Reality with TI SimpleLink Wi-Fi CC32001
Make the Internet of Things a reality with TI SimpleLink Wi-Fi CC32001 : https://training.eeworld.com.cn/course/322...
cuipin Talking
Streaming driver loading, a strange problem 1
When the streaming driver is loaded, why doesn't the serial port driver call the com_powerup function when the computer is turned on? In theory, the POWERUP function of all streaming drivers will be c...
liuchangjun1981 Embedded System
J-link problem cannot be refreshed, please help me find out where the setting is wrong
[i=s] This post was last edited by argox on 2016-9-26 10:19 [/i]The processor of the board is AT91SAM9G25. I am a novice and don't know what the problem is or if there is something wrong with the sett...
argox ARM Technology
Is there an API to turn off touch sound on WinCE?
As the title says: Is there an API to turn off touch sound on WinCE? ? ? ?...
rainfeng Embedded System
How to write the Windows driver for cp2102
Due to work needs, I wrote a cp2102 windows driver. Now I have finished writing read and write, and a simple model has been produced. But I am not very familiar with whether my driver needs to handle ...
zry113 Embedded System
How to avoid PCB design pitfalls?
[i=s]This post was last edited by cb51 on 2014-8-29 13:56[/i] For an electronic engineer, circuit design is a basic skill. However, even if the circuit schematic is perfect, if you do not understand a...
cb51 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2629  2503  504  1003  388  53  51  11  21  8 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号