DATASHEET
Rev. E
LANCUW8 SERIES
4:1 Ultra Wide Input Voltage Ranges
Single and Dual Outputs
SMT and DIP Packages
8 Watt DC/DC Power Converters
FEATURES
Single and Dual Outputs
4:1 Ultra Wide Input Voltage Ranges
High Efficiency up to 88%
8 Watts Output Power
1600VDC I/O Isolation
Output Current up to 2.4A
Remote ON/OFF
Fixed Switching Frequency (300KHz)
Over Voltage, Over Load, and Short Circuit Protection
Five-Sided Continuous Shield
Railway Applications
Standard 1.25” x 0.80” x 0.40” and 24 Pin DIP Package
SMT Package Available (Suffix “S”)
Compliant to RoHS EU Directive 2002/95/EC
CE Mark Meets 2006/95/EC, 93/68/EEC and 2004/108/EC
UL60950-1, EN60950-1, IEC60950-1, and EN50155 Safety
Approvals (Pending)
APPLICATIONS
Railway Systems
Wireless Networks
Telecom / Datacom
Measurement Equipment
Industry Control Systems
Semiconductor Equipment
DESCRIPTION
The LANCUW8 series of DC/DC power converters provides 8 Watts of output power in a 1.25 x 0.80 x 0.40 inch DIP
package. This series has single and dual output models with 4:1 wide input voltage ranges of 9-36VDC, 18-75VDC, and
43-160VDC. Some features include high efficiency up to 88%, 1600VDC I/O isolation, five-sided shielding, remote
ON/OFF control, and no minimum load requirement. These converters are also protected against over voltage (single
outputs only), over load, and short circuit conditions. All models are RoHS compliant and have UL60950-1, EN60950-1,
IEC60950-1, and EN50155 safety approvals (pending). This series is best suited for use in wireless networks,
telecom/datacom, measurement equipment, industry control systems, semiconductor equipment, and railway systems.
06/14/2012
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
Page 1 of 5
Rev. E
LANCUW8 Series
Single & Dual Outputs
4:1 Input Voltage Range
8 Watt DC/DC Power Converters
SPECIFICATIONS: LANCUW8 Series
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
INPUT SPECIFICATIONS
Input Voltage Range
Input Surge Voltage (100ms max)
Start-Up Voltage
Shutdown Voltage
Input Reflected Ripple Current
Remote ON/OFF
(See Note 6)
Input Current of Remote Control Pin
Remote Off State Input Current
Input Filter
OUTPUT SPECIFICATIONS
Output Voltage
Line Regulation
DC/DC ON
DC/DC OFF
Nominal Vin
Nominal Vin
TEST CONDITIONS
24VDC nominal input models
48VDC nominal input models
110VDC nominal input models
24VDC nominal input models
48VDC nominal input models
110VDC nominal input models
24VDC nominal input models
48VDC nominal input models
110VDC nominal input models
24VDC nominal input models
48VDC nominal input models
110VDC nominal input models
Nominal Vin and full load
Min
9
18
43
Nom
24
48
110
Max
36
75
160
50
100
170
9
18
43
Unit
VDC
VDC
VDC
VDC
mAp-p
mA
mA
-0.5
8
16
42
20
Open or 3.0V < Vr < 12V
Short or 0V < Vr < 1.2V
+0.5
2.5
Pi type
See Table
+0.2
+0.5
+1
+1
+0.3
+0.8
+0.8
+5
+1
8
See Table
See Table
250
450
Low line to high line at full load
No load to full load
Single Output (DIP)
Single Output (SMT)
Dual Output (DIP & SMT)
Single Output (DIP)
Single Output (SMT)
Dual Output (DIP & SMT)
Load Regulation
10% load to 90% load
Cross Regulation (Dual Outputs)
Voltage Accuracy
Output Power
Output Current
Ripple & Noise
Transient Response Recovery Time
Start-Up Time
Minimum Load
Temperature Coefficient
PROTECTION
Over Load Protection
Short Circuit Protection
Over Voltage Protection
(Single Outputs only)
GENERAL SPECIFICATIONS
Efficiency
Switching Frequency
Isolation Voltage
Isolation Resistance
Isolation Capacitance
ENVIRONMENTAL SPECIFICATIONS
5V, 12V, 15V, ±12V, & ±15V output models
Operating Ambient Temperature
(See Note 7)
3.3V and ±5V output models
Maximum Case Temperature
Storage Temperature
Relative Humidity
Thermal Shock
Vibration
Thermal Impedance
MTBF
(See Note 1)
PHYSICAL SPECIFICATIONS
Weight
Case Material
Base Material
Potting Material
Dimensions (L x W x H)
SAFETY & EMC CHARACTERISTICS
Safety Approvals (Pending)
EMI
(See Note 8)
ESD
Radiated Immunity
Fast Transient
(See Note 9)
Surge
(See Note 9)
Conducted Immunity
Asymmetrical load 25% / 100% full load
Full load an nominal Vin
20MHz Bandwidth
25% load step change
Nom. Vin and constant resistive load
-0.2
-0.5
-1
-1
-0.3
-0.8
-0.8
-5
-1
%
%
%
%
%
W
µs
ms
%
%/°C
%
Power Up
0
-0.02
+0.02
150
Continuous, automatic recovery
3.9
6.2
15
18
See Table
300
% of full load at nominal input
3.3V output model
5.0V output model
12V output model
15V output model
Nominal Vin and full load
Input to Output (DIP & SMT)
Input (Output) to Case (DIP)
Input (Output) to Case (SMT)
1600
1600
1000
10
VDC
KHz
VDC
1500
GΩ
pF
°C
°C
°C
°C
% RH
°C/Watt
without derating
with derating
without derating
with derating
-40
+78
-40
+70
-55
5
Natural Convection
BELLCORE TR-NWT-000332
MIL-HDBK-217F
+78
+105
+70
+105
+105
+125
95
EN61373, MIL-STD-810F
EN61373, MIL-STD-810F
20
2,350,000 hours
1,078,000 hours
0.62oz (18g)
Nickel-coated copper
Non-conductive black plastic
Epoxy (UL94-V0)
1.25 x 0.80 x 0.40 inches (31.8 x 20.3 x 10.2 mm)
EN55022, EN55011
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Air
Contact
±8KV
±6KV
20 V/m
±2KV
±2KV
10 Vrms
IEC60950-1, UL60950-1, EN60950-1, EN50155
Class A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
06/14/2012
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
Page 2 of 5
Rev. E
LANCUW8 Series
Single & Dual Outputs
4:1 Input Voltage Range
8 Watt DC/DC Power Converters
MODEL SELECTION TABLES
SINGLE OUTPUT MODELS
Model Number
LANC2433UW8
LANC2405UW8
LANC2412UW8
LANC2415UW8
LANC4833UW8
LANC4805UW8
LANC4812UW8
LANC4815UW8
LANC11033UW8
LANC11005UW8
LANC11012UW8
LANC11015UW8
110 VDC
(43 - 160 VDC)
48 VDC
(18 - 75 VDC)
24 VDC
(9 - 36 VDC)
Input Voltage
Range
Output
Voltage
3.3 VDC
5 VDC
12 VDC
15 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
Output Current
Min. Load Full Load
0mA
2400mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
1600mA
666mA
533mA
2400mA
1600mA
666mA
533mA
2400mA
1600mA
666mA
533mA
Input Current
Output
(4)
No Load
(3)
Full Load
(2)
Ripple & Noise
40mA
407mA
50mVp-p
40mA
25mA
25mA
20mA
20mA
13mA
13mA
8mA
8mA
4mA
4mA
402mA
407mA
407mA
204mA
201mA
201mA
198mA
82mA
90mA
88mA
88mA
50mVp-p
50mVp-p
50mVp-p
50mVp-p
50mVp-p
50mVp-p
50mVp-p
75mVp-p
75mVp-p
75mVp-p
75mVp-p
Output
Power
8W
8W
8W
8W
8W
8W
8W
8W
8W
8W
8W
8W
Efficiency
(4)
85%
87%
86%
86%
85%
87%
87%
88%
84%
85%
86%
86%
Maximum
(5)
Capacitive Load
1330μF
1330μF
288μF
200μF
1330μF
1330μF
288μF
200μF
1330μF
1330μF
288μF
200μF
DUAL OUTPUT MODELS
Model Number
LANC2405DUW8
LANC2412DUW8
LANC2415DUW8
LANC4805DUW8
LANC4812DUW8
LANC4815DUW8
LANC11005DUW8
LANC11012DUW8
LANC11015DUW8
Input Voltage
Range
24 VDC
(9 - 36 VDC)
48 VDC
(18 - 75 VDC)
110 VDC
(43 - 160 VDC)
Output
Voltage
±5 VDC
±12 VDC
±15 VDC
±5 VDC
±12 VDC
±15 VDC
±5 VDC
±12 VDC
±15 VDC
Output Current
Min. Load Full Load
0mA
±800mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
±333mA
±267mA
±800mA
±333mA
±267mA
±800mA
±333mA
±267mA
Input Current
Output
(6)
No Load
(3)
Full Load
(2)
Ripple & Noise
20mA
417mA
50mVp-p
25mA
25mA
10mA
13mA
13mA
5mA
5mA
5mA
407mA
407mA
208mA
201mA
201mA
93mA
90mA
90mA
50mVp-p
50mVp-p
50mVp-p
50mVp-p
50mVp-p
75mVp-p
75mVp-p
75mVp-p
Output
Power
8W
8W
8W
8W
8W
8W
8W
8W
8W
Efficiency
(4)
84%
86%
86%
84%
87%
87%
82%
85%
85%
Maximum
(5)
Capacitive Load
±900µF
±133µF
±90µF
±900µF
±133µF
±90µF
±900µF
±133µF
±90µF
NOTES
1. BELLCORE TR-NWT-000332. Case 1: 50% Stress, Temperature at 40°C.
MIL-HDBK-217F Notice2 @Ta=25°C, Full load (Ground, Benign, controlled environment).
2. Maximum value at nominal input voltage and full load.
3. Typical value at nominal input voltage and no load.
4. Typical value at nominal input voltage and full load.
5. Test by minimum Vin and constant resistive load.
6. The ON/OFF control pin voltage is referenced to -Vin.
7. Operating Ambient Temperature:
Converters can meet the railway T2 and TX temperature requirements.
T2: -40°C to +70°C for all models, TX: -40°C to +85°C with power derating to 55% output power.
8. The LANCUW8 series can meet EN55022 and EN55011 Class A with an external capacitor on the input pins to the converter.
Recommended: 24Vin Models: 1µF/50V 1210 MLCC
48Vin Models: 0.47µF/100V 1812 MLCC
110Vin Models: 1µF/250V*2pcs 1812 MLCC
9. An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5.
Recommended: 24Vin & 48Vin Models: Nippon chemi-con KY series, 220µF/100V
110Vin Models: Nippon chemi-con KXJ series, 150µF/200V
10. For surface mount (SMT) type add the suffix “S” to the model number. Ex: LANC2405UW8S.
11.
CAUTION:
This power module is not internally fused. An input line fuse must always be used.
06/14/2012
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
Page 3 of 5
Rev. E
LANCUW8 Series
Single & Dual Outputs
4:1 Input Voltage Range
8 Watt DC/DC Power Converters
CHARACTERISTICS
LANC4805UW8 DERATING CURVE
120
100
OUTPUT POWER (%)
EFFICIENCY (%)
LANC4805UW8
EFFICIENCY VS INPUT VOLTAGE
95
90
85
80
75
70
81
65
100
120
18
24
30
36
42
48
54
60
66
72
75
INPUT VOLTAGE (V)
EFFICIENCY (%)
LANC4805UW8
EFFICIENCY VS OUTPUT LOAD
95
90
85
80
75
70
65
10
20
30
40
50
60
70
80
90
100
OUTPUT LOAD (% OF FULL LOAD)
80
60
40
20
0
-40
-20
0
20
40
60
80
AMBIENT TEMPERATURE (°C)
Recommended Filter for EN55022 Class B Compliance
C3
Recommended EN55022 Class B Filter Circuit Layout
+INPUT
C1
L1
+Vin
+
+Vout
C2
C5
DC/DC
CONVERTER
-Vin
-Vout
LOAD
-INPUT
C4
The components used in the figure above are as follows:
MODEL
LANC24xxUW8
LANC48xxUW8
LANC110xxUW8
C1
4.7µF/50V
1812 MLCC
1.5µF/100V
1812 MLCC
1µF/250V
1812 MLCC
Unit: inches (mm)
C2
N/A
1.5µF/100V
1812 MLCC
N/A
C3
1000pF/2KV
MLCC
1000pF/2KV
MLCC
1000pF/2KV
MLCC
0.43 (11.0) ref.
C4
1000pF/2KV
MLCC
1000pF/2KV
MLCC
1000pF/2KV
MLCC
C5
N/A
N/A
22µF/200V
L1
325µH Common
Choke PMT-050
325µH Common
Choke PMT-050
325µH Common
Choke PMT-050
Common Choke L1
PMT-050
L: 325μH±35% / DCR: 35mΩ, max.
0.30±0.008 (7.5±0.2)
Test Conditions: 100KHz / 100mV
Recommended Through Hole: Ø0.8mm
PMT-017
L: 497μH±25% / DCR: 80mΩ, max.
Test Conditions: 100KHz / 20mV
Recommended Through Hole: Ø0.8mm
0.43 (11.0) ref.
Ø0.02±0.004 (Ø0.6±0.1)
0.35 (8.8) ref.
4
N2
3
1
N1
2
0.30±0.008 (7.62±0.2)
06/14/2012
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
0.1
(2.5)
Page 4 of 5
Rev. E
LANCUW8 Series
Single & Dual Outputs
4:1 Input Voltage Range
8 Watt DC/DC Power Converters
MECHANICAL DRAWING
DIP TYPE
Unit: inches (mm)
0.100 (2.54)
Pin size is 0.02 (0.5) Dia or
0.01 x 0.02 (0.25 x 0.50) Rectangular Pin
SMT TYPE
(add Suffix “S”)
Unit: inches (mm)
0.100 (2.54)
1.00 (25.4)
0.90 (22.9)
0.02 (0.5)
0.44 (11.2)
0.43 (10.9)
0.08 (2.0)
0.800 (20.32)
23
22
1.25 (31.8)
24
1
0.200 (5.08)
BOTTOM
VIEW
16
14
9
11
BOTTOM
VIEW
0.25 (6.4)
16
13
0.80 (20.3)
9
12
Pin Area
0.04 x 0.02
(1.0 x 0.5)
0.600 (15.24)
0.80 (20.3)
0.15 (3.8)
0.40 (10.2)
1. Tolerance: X.XX±0.02 (X.X±0.5)
X.XXX±0.01 (X.XX±0.25)
2. Pin pitch tolerance ±0.01 (0.25)
(DIP) PIN CONNECTION
PIN
1
2
3
9
11
SINGLE
CTRL
-INPUT
-INPUT
NC
NC
DUAL
CTRL
-INPUT
-INPUT
COMMON
-OUTPUT
23
22
16
14
+INPUT
+INPUT
-OUTPUT
+OUTPUT
+INPUT
+INPUT
COMMON
+OUTPUT
PIN
SINGLE
DUAL
PIN
1
2
3
9
11
Others
SINGLE
CTRL
-INPUT
-INPUT
NC
NC
NC
(SMT) PIN CONNECTION
DUAL
CTRL
-INPUT
-INPUT
COMMON
-OUTPUT
NC
23
22
16
14
Others
+INPUT
+INPUT
-OUTPUT
+OUTPUT
NC
+INPUT
+INPUT
COMMON
+OUTPUT
NC
PIN
SINGLE
DUAL
COMPANY INFORMATION
Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development
engineers will provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008
certification is just one example of our commitment to producing a high quality, well-documented product for our customers.
Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working
closely with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to
provide ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss
your future projects.
Contact
Wall Industries
for further information:
Phone:
Toll Free:
Fax:
E-mail:
Web:
Address:
(603)778-2300
(888)587-9255
(603)778-9797
sales@wallindustries.com
www.wallindustries.com
5 Watson Brook Rd.
Exeter, NH 03833
Page 5 of 5
06/14/2012
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
1.26 (32.0)
20
5
0.15 (3.8)
1
2
3