Chip-immune Inductive Proximity Sensor
E2EZ
CSM_E2EZ_DS_E_6_1
Chip-immune Inductive
Proximity Sensor
• Correct operation even with aluminum or iron chips sticking
to the Sensor.
Only the sensing object is detected.
• Pre-wired Smartclick Connector Models also available.
Be sure to read
Safety Precautions
on
page 7.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Ordering Information
Sensors
[Refer to
Dimensions
on page 8.]
Pre-wired Models
Model
Appearance
Sensing distance
Output configuration
NO
M12
Operation mode
NC
E2EZ-X2D2-N 2M
—
E2EZ-X4D2-N 2M
—
—
E2EZ-X8D2-N 2M
2 mm
DC 2-Wire Models
DC 3-wire, NPN
E2EZ-X2D1-N 2M
E2EZ-X4C1 2M
E2EZ-X4D1-N 2M
E2EZ-X4Y1 2M
E2EZ-X8C1 2M
E2EZ-X8D1-N 2M
E2EZ-X8Y1 2M
M18
Shielded
4 mm
DC 2-wire
AC 2-wire
DC 3-wire, NPN
M30
8 mm
DC 2-wire
AC 2-wire
Pre-wired Smartclick Connector Models (M12)
Model
Appearance
Sensing distance
Output configuration
NO
DC 2-wire, (3)-(4) pin arrangement
M12
E2EZ-X2D1-M1TJ 0.3M
E2EZ-X2D1-M1TGJ 0.3M
E2EZ-X4D1-M1TJ 0.3M
E2EZ-X4D1-M1TGJ 0.3M
E2EZ-X8D1-M1TJ 0.3M
E2EZ-X8D1-M1TGJ 0.3M
Operation mode
NC
—
—
—
—
—
—
2 mm
DC 2-wire, (1)-(4) pin arrangement
DC 2-wire, (3)-(4) pin arrangement
Shielded
M18
4 mm
DC 2-wire, (1)-(4) pin arrangement
DC 2-wire, (3)-(4) pin arrangement
M30
8 mm
DC 2-wire, (1)-(4) pin arrangement
1
E2EZ
Pre-wired Connector Models (M12)
Model
Appearance
Sensing distance
Output configuration
NO
DC 2-wire, (3)-(4) pin arrangement
M12
E2EZ-X2D1-M1J 0.3M
E2EZ-X2D1-M1GJ 0.3M
E2EZ-X4D1-M1J 0.3M
E2EZ-X4D1-M1GJ 0.3M
E2EZ-X8D1-M1J 0.3M
E2EZ-X8D1-M1GJ 0.3M
Operation mode
NC
—
—
—
—
—
—
2 mm
DC 2-wire, (1)-(4) pin arrangement
DC 2-wire, (3)-(4) pin arrangement
Shielded
M18
4 mm
DC 2-wire, (1)-(4) pin arrangement
DC 2-wire, (3)-(4) pin arrangement
M30
8 mm
DC 2-wire, (1)-(4) pin arrangement
Accessories (Order Separately)
Sensor I/O Connectors (M12, Sockets on One Cable End)
(Models for Pre-wired Connectors: A Connector is not provided with the Sensor. Be sure to order a Connector separately.)
[Refer to
Dimensions
on
XS2, XS5.]
Appearance
Cable length
2m
5m
2m
5m
2m
5m
2m
5m
2m
5m
Sensor I/O Connector model number
XS2F-D421-DD0
XS2F-D421-GD0
XS2F-D422-DD0
XS2F-D422-GD0
XS2F-D421-DA0-F
XS2F-D421-GA0-F
XS2F-D422-DA0-F
XS2F-D422-GA0-F
XS5F-D421-D80-F
XS5F-D421-G80-F
E2EZ-X@D1-M1TJ
E2EZ-X@D1-M1TGJ
E2EZ-X@D1-M1GJ
E2EZ-X@D1-M1J
Applicable Proximity Sensor model number
Straight
L-shape
Straight
L-shape
Smartclick
Connector
Straight
Mounting Brackets
Protective Covers
Sputter Protective Covers
Refer to
Y92
@
for details.
2
E2EZ
Ratings and Specifications
Item
Model E2EZ-X2D@-N
E2EZ-X2D@-M1J
E2EZ-X2D@-M1GJ
2 mm
±10%
0 to 1.6 mm
E2EZ-X4D@-N
E2EZ-X4D@-M1J
E2EZ-X4D@-M1GJ
4 mm
±10%
0 to 3.2 mm
E2EZ-X8D@-N
E2EZ-X8D@-M1J
E2EZ-X8D@-M1GJ
8 mm
±10%
0 to 6.4 mm
E2EZ-X4C1
E2EZ-X4Y1
4 mm
±10%
0 to 3.2 mm
E2EZ-X8C1
E2EZ-X8Y1
8 mm
±10%
0 to 6.4 mm
Sensing distance
Set distance
*1
Differential travel
Detectable object
Standard sensing
object
Response
frequency
*2
Power supply volt-
age
(operating voltage
range)
Current
consumption
Leakage current
Load cur-
rent
20% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data
on page 4.)
Iron, 12
×
12
×
1 mm
200 Hz
Iron, 30
×
30
×
1 mm
100 Hz
Iron, 54
×
54
×
1 mm
30 Hz
Iron, 30
×
30
×
1 mm
C Models: 12 Hz
Y Models: 5 Hz
Iron, 54
×
54
×
1 mm
C Models: 8 Hz
Y Models: 5 Hz
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
C Models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p):
10% max.
Y Models: 100 to 220 VAC (90 to 250 VAC), 50/60 Hz
C Models: 15 mA max.
Y Models: 2 mA max. at 100 VAC, 3 mA max. at 200 VAC
C Models: NPN open-collector output
100 mA max. at 12 VDC (30 VDC max.)
200 mA max. at 24 VDC (30 VDC max.)
Y Models: 10 to 200 mA
C Models: 2 V max. (Load current: 200 mA, Cable length:
2 m)
Y Models: Refer to residual voltage characteristic data
Refer to page 4.
C Models: Detection indicator (red)
Y Models: Operation indicator (red)
NO
For details, refer to the
Timing chart
on page 6.
C Models: Load short-circuit protection, Reverse polarity
protection, Surge suppressor
Y Models: Surge suppressor
---
0.8 mA max.
3 to 100 mA max.
Con-
trol
output
Residual
voltage
3 V max. (Load current: 100 mA, Cable length: 2 m)
D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)
D1 Models: NO
D2 Models: NC
For details, refer to the
Timing chart
on page 5.
Load short-circuit protection, Surge suppressor
Operating/Storage: 0 to 50°C (with no icing or condensation)
Operating/Storage: 35% to 95% (with no condensation)
±20%
max. of sensing distance at 23°C in the temperature range of 0 to 50°C
±2.5%
max. of sensing distance at rated voltage in the rated voltage
±10%
range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
Indicators
Operation mode
(with sensing ob-
ject approaching)
Protection
circuits
Ambient
temperature range
Ambient
humidity range
Temperature
influence
Voltage influence
Insulation
resistance
Dielectric strength
Vibration
resistance
Shock resistance
Degree of
protection
Connection
method
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
C Models: 1,000 VAC, 50/60 Hz for 1 min between cur-
rent-carrying parts and case
Y Models: 2,000 VAC, 50/60 Hz for 1 min between cur-
rent-carrying parts and case
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 1,000 m/s
2
10 times each in X, Y, and Z directions
IEC 60529 IP67, in-house standards: oil-resistant
Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models
E2EZ-X2D@-N: Approx.
70 g
E2EZ-X2D@-M1J: Approx.
40 g
E2EZ-X2D@-M1GJ:
Approx. 40 g
Nickel-plated brass
PBT
Zinc-plated iron
Zinc-plated iron
Instruction manual
Heat-resistant ABS
E2EZ-X4D@-N: Approx.
160 g
E2EZ-X4D@-M1J:
Approx. 90 g
E2EZ-X4D@-M1GJ:
Approx. 90 g
E2EZ-X8D@-N: Approx.
220 g
E2EZ-X8D@-M1J:
Approx. 160 g
E2EZ-X8D@-M1GJ:
Approx. 160 g
Weight
(packed state)
Approx. 170 g
Approx. 270 g
Case
Sensing
surface
Clamp-
ing nuts
Toothed
washer
Accessories
Materi-
als
*1. Use the Sensor within the range in which the green indicator is ON.
*2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
3