DC/DC Converter
IB_(X)T-1W & IB_(X)T-W75 Series
Fixed input voltage, isolated & regulated
single output
FEATURES
Continuous Short Circuit Protection
Operating temperature range: -40℃ to +105℃
Isolation voltage: 1K VDC
Ultra Compact SMD package
Internal surface mounted desig
International standard pin-out
Patent Protection
RoHS
IB_(X)T-1W & IB_(X)T-W75 series is specially designed for applications where an isolated voltage is required in a distributed power supply
system. It is suitable for
1.Where the voltage of the input power supply is stable (voltage variation: ±5%Vin).
2.Where isolation is necessary between input and output (isolation voltage
≤1000VDC).
3.Where has high requirement of line regulation , load regulation and the ripple & noise of the output voltage.
Selection Guide
Input Voltage (VDC)
Part No.
IB0305T-W75
IB0305XT-1W
IB0505(X)T-W75
IB0512(X)T-1W
IB0515T-1W
IB1205(X)T-W75
IB1212(X)T-1W
IB1215T-1W
3.3
(3.13~3.46)
5
(4.75~5.25)
Nominal
(Range)
Output Voltage
(VDC)
5
5
5
12
15
5
12
15
Output
Output Current (mA)
(Max./Min.)
150/15
200/20
150/15
83/9
67/7
150/15
83/9
67/8
Efficiency
(%,
Min./T
yp.)
@ Full Load
63/67
60/64
64/68
65/69
65/69
63/67
65/69
66/70
220
Max. Capacitive
Load(μF)
12
(11.4~12.6)
Note: 1. IB_XT-1W series have no 3,6,8,9 pin, for example IB0505XT-W75.
Input Specifications
Item
Input Current (full load / no-load)
Operating Conditions
3.3V input
5V input
12V input
3.3V input
Surge Voltage (1sec. max.)
Input Filter
5V input
12V input
Min.
--
--
--
-0.7
-0.7
-0.7
Typ.
500/40
300/30
130/20
--
--
--
Max.
--
--
--
5
9
15
VDC
mA
Unit
Capacitor filter
Output Specifications
Item
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple*
Noise*
Temperature Drift Coefficient
Output Short Circuit Protection
Input voltage change: ±1%
10%-100% load
20MHz bandwidth
100% load
--
--
--
--
--
Operating Conditions
Min.
Typ.
--
12
10
50
--
Max.
±1.2
--
20
100
±0.03
Unit
See tolerance envelope graph (Fig. 1)
%
mVp-p
%/℃
Continuous, self-recovery
Note: * Ripple and noise tested with “parallel cable” method, please see
DC-DC Converter Application Notes
for specific operation methods.
2014.05.16-B/1
Page 1 of 3
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
IB_(X)T-1W & IB_(X)T-W75 Series
General Specifications
Item
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Operating Temperature
Storage Temperature
Casing Temperature Rise
Pin Welding Resistance Temperature
Reflow Soldering Temperature
Storage Humidity
Switching Frequency
MTBF
Non-condensing
100% load, nominal input voltage
MIL-HDFK-217F@25℃
Ta=25℃
Welding spot is 1.5mm away from the casing,
10 seconds
Operating Conditions
Input-output, with the test time of 1 minute and
the leak current lower than 1mA
Input-output, Isolation voltage 500VDC
Input-output, 100KHz/0.1V
Derating if the temperature
≥71℃
(see Fig. 2)
Min.
1000
1000
--
-40
-55
--
--
Typ.
--
--
40
--
--
15
--
Max.
--
--
--
85
125
25
260
℃
Unit
VDC
MΩ
pF
Peak temp.≤245℃, maximum duration time≤60s
at 217℃. For actual application, please refer to
IPC/JEDEC J-STD-020D.1.
--
--
3500
--
100
--
95
--
--
%
KHz
K hours
Physical Specifications
Casing Material
Package Dimensions
Weight
Cooling Method
Black flame-retardant heat-proof epoxy resin (UL94-V0)
15.24*11.20*6.50 mm
1.7 g (Typ.)
Free air convection
EMC Specifications
EMI
EMS
Conducted disturbance
Electrostatic discharge
CISPR22/EN55022
IEC/EN61000-4-2
CLASS A (see Fig. 4 for recommended circuit)
Contact ±6KV
perf. Criteria B
Product Characteristic Curve
Output Pow er Per centage(%)
Tolerance Envelope Graph
+10%
+5%
Rated
Output Voltage
Output Voltage
Accuracy
(%)
Tempe ratu re D erating Graph
120
100
80
60
40
20
0
-40
120
40
0
71 85
Ambi ent Temperature(
℃
)
Safe Operati ng Area
Ty p ic a
l L o ad
Cur v e
+2.5%
-2.5%
-7.5%
50
70
100
Output Current Percentage(%)
(Nominal Input Voltage)
Fig. 1
Fig. 2
Design Reference
1. Typical application
If it is required to further reduce input and output ripple, a “LC” filter capacitor can be connected to the input and output terminals, see
Fig.3.
It should also be noted that the inductance and the frequency of the “LC” filtering network should be staggered with the DC/DC
frequency to avoid mutual interference. However, the capacitance of the output filter capacitor must be proper. If the capacitance is
too big, a startup problem might arise. For every channel of output, provided the safe and reliable operation is ensured, the greatest
capacitance of its filter capacitor sees Table 1.
Recommended capacitive load value table (Table 1)
Vin
GND
Cin
L
L
+Vo
Cout
Vin
(VDC)
3.3
5
12
Cin
(μF)
4.7
4.7
2.2
Vout
(VDC)
5
12
15
Cout
(μF)
4.7
1
1
DC DC
Fig.3
0V
It is not recommended to connect any external capacitor when
output power is less than 0.5W.
2014.05.16-B/1
Page 2 of 3
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
IB_(X)T-1W & IB_(X)T-W75 Series
2. EMC typical recommended circuit
LDM
Vin
C1
GND
Vin
+Vo
Input voltage (VDC)
3.3/5/12
4.7μF /50V
Refer to the Cout in Fig.3
6.8μH
DC/DC
GND
0V
C2
LOAD
C1
EMI
C2
LDM
Fig. 4
3. Output load requirements
To ensure the module work efficiently and reliably, during the operation, the min. output load should be no less than 10% of the full load. If
the actual output power is low, please connect a resister to the output terminal in parallel, with a recommenced resistance which is 10% of
the rated power, and derating is required during operation.
4. For more information please find the application notes on www.mornsun-power.com
Dimensions and Recommended Layout
Notes:
1.
2.
3.
4.
5.
6.
7.
8.
Packing Information please refer to 'Product Packing Information'. Packing bag number: 58200019;
If the product is operated under the min. required load, the product performance cannot be guaranteed to comply with all
performance indexes in this datasheet;
The max. capacitive load should be tested within the input voltage range and under full load conditions;
Unless otherwise specified, data in this datasheet should be tested under the conditions of Ta=25°C, humidity<75% when inputting
nominal voltage and outputting rated load;
All index testing methods in this datasheet are based on our Company’s corporate standards;
The performance indexes of the product models listed in this manual are as above, but some indexes of non-standard model products
will exceed the above-mentioned requirements, and please directly contact our technicians for specific information;
We can provide product customization service;
Specifications of this product are subject to changes without prior notice.
MORNSUN Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China
Tel: 86-20-38601850-8801
Fax: 86-20-38601272
E-mail:
info@mornsun.cn
2014.05.16-B/1
Page 3 of 3
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation