Part Number

Search

K1ABBCBCCC

Description
Rocker Switch, SPDT, On-on, Maintained, 10A, 28VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size2MB,3 Pages
ManufacturerOTTO
Websitehttp://www.ottoexcellence.com
Environmental Compliance
Download Datasheet Parametric View All

K1ABBCBCCC Overview

Rocker Switch, SPDT, On-on, Maintained, 10A, 28VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount

K1ABBCBCCC Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid315806094
Reach Compliance Codeunknown
ECCN codeEAR99
Actuator colorBLACK
Actuator length0.29 inch
Actuator materialTHERMOPLASTIC
Actuator typeROCKER
Other features12V INCANDESCENT LIGHT
body width11.938 mm
body height26.67 mm
Body length or diameter27.178 mm
Center contact platingSILVER
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@28VDC
Contact functionON-ON
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)28 V
Dielectric withstand voltage1050VRMS V
Electrical life50000 Cycle(s)
End contact platingSILVER
illuminationLAMP
insulator materialTHERMOPLASTIC
Manufacturer's serial numberK1
Installation featuresPANEL MOUNT
Maximum operating temperature85 °C
Minimum operating temperature-30 °C
surface mountNO
Switch actionMAINTAINED
switch functionSPDT
Switch typeROCKER SWITCH
Terminal length0.4 inch
Termination typeQUICK CONNECT

K1ABBCBCCC Preview

SEALED, ILLUMINATED ROCKER SWITCHES
LOW COST, SNAP-IN ROCKER FOR WET & DUSTY ENVIRONMENTS
K1/K2
SNAP-IN
ROCKERS
The K series rockers are rugged, high performance sealed
switches designed for use under severe conditions found in
marine, appliance, heavy equipment and industrial control
applications. Sealed to IP68S with an optional panel gasket
available.
The K1 series is offered in single pole configuration while the
K2 series is available in single and double pole configurations.
Both series offer illuminated models. Illumination can be
independent or dependent of the switch position or a
combination of both. A choice of red, green, clear or amber
colored lenses are offered in illuminated models. Illumination
options include incandescent, LED or neon light sources.
Mounting is simple and quick; snaps into panel from the
front. The OTTO snap-in design supports a variety of panel
thicknesses with just one cutout size specified.
A choice of models are offered to handle power levels to 16 amps,
1/2 HP and low level electronic switching applications.
OTTO can provide custom colors upon request. Value-added
assemblies with wire leads are also available. Please consult
the factory for assistance.
ROCKER SWITCHES
K1 Series
Single Pole
K2 Series
Single & Double Pole
C
Features:
• Withstands direct water spray
• Watertight to IP68S
• Fits industry standard panel openings for drop-in
replacement of panel sealed & unsealed switches
• Snap-in feature accommodates a wide range of
panel cutouts
• Switches up to 16 amps
• UV & solvent resistant
• Withstands extreme shock & vibration
• Custom legends available
• 2 & 3-position, momentary & maintained action
• Incandescent, LED & neon illumination with
independent & dependent light source options
• UL recognized & CSA certified
• Ignition protected
• RoHS/WEEE/Reach compliant
Standard Characteristics/Ratings:
ELECTRICAL RATINGS:
Load
Resistive
Resistive
Inductive
Lamp
Motor
DWV
Low Level
Electrical Life:
Sea Level @ 28VDC
or 125/250VAC, 60Hz
16A
10A
10A
5A
0.5HP
10mA @ 30mV
See Rating Chart
Cycles
25,000
50,000
25,000
25,000
25,000
®
US
1050Vrms except across light terminals
LIGHTING:
Light Source
Incandescent
Neon
LED
Mechanical Life:
Seal:
Rating
(VDC) 6V, 12V, 24V
(VAC) 125V, 250V
(VDC) 2V, 6V, 12V, 24V
100,000 cycles
IP68S
Operating Temp Range:
-30°C to +85°C
MATERIALS:
Case:
Button:
Base:
Terminals/Contact:
Terminal Hardware:
Thermoplastic
Thermoplastic
Thermoplastic
Brass, silver alloy with silver plate, gold flash for low level
Screws and lockwashers provided when applicable
K1/K2 series recommended Quick Connect terminals:
AMP 60253-2 for 12-16 AWG
AMP 42100-2 for 14-18 AWG
None provided
Mounting Hardware:
Specifications Subject To Change Without Notice
www.ottoexcellence.com
147
K1
SNAP-IN
ROCKERS
SEALED, ILLUMINATED ROCKER SWITCHES
LOW COST, SNAP-IN ROCKER FOR WET & DUSTY ENVIRONMENTS
K1 PART NUMBER CODE
K1
Terminal Style/
Switch Rating
A.
Q.C./Std.
B.
Screw/Std.
C.
Solder/Std.
D.
Q.C./Low Level
E.
Screw/Low Level
F.
Solder/Low Level
G.
PC Pin/Std.
H.
PC Pin/Low Level
X
X
X
Switch Action/Circuit
Position Position Position Circuit
“A”
“B”
“C”
A.
B.
C.
D.
E.
F.
G.
H.
Part Number Code Continued Below
X
Actuator Color/Style
A.
Red/Rocker
B.
Black/Rocker
C.
White/Rocker
D.
Red/Paddle
E.
Black/Paddle
F.
White/Paddle
G.
Red/Rocker Pinned
H.
Black/Rocker Pinned
J.
White/Rocker Pinned
K.
Red/Short Paddle Pinned
L.
Black/Short Paddle Pinned
M.
White/Short Paddle Pinned
N.
Red/Standard Paddle Pinned
P.
Black/Standard Paddle Pinned
R.
White/Standard Paddle Pinned
T.
Red/Short Paddle
U.
Black/Short Paddle
V.
White/Short Paddle
Light Type
A.
No Light
B.
6V Incandescent
C.
12V Incandescent
D.
24V Incandescent
E.
125VAC Neon
F.
250VAC Neon
G.
2V Red LED
H.
2V Green LED
J.
2V Amber LED
K.
6V Red LED
L.
6V Green LED
M.
6V Amber LED
N.
12V Red LED
P.
12V Green LED
Q.
12V Amber LED
R.
24V Red LED
S.
24V Green LED
T.
24V Amber LED
1-C
1-C
(1-C)
(
1-C)
(1-C)
1-C
(1-C)
OFF
Position “A”
NONE
NONE
NONE
NONE
OFF
OFF
OFF
NONE
Position “B”
OFF
2-C
OFF
2-C
(2-C)
2-C
2-C
2-C
SPST
SPDT
SPST
SPDT
SPDT
SPDT
SPDT
SPST
Position “C”
NOTE
: ( ) denotes momentary action.
K1
Continued
X
X
K1 PART NUMBER CODE
CONTINUED FROM ABOVE
X
Light/Circuit Location
A.
No Light
B.
F.
B.
X
Legend & Orientation
A.
None
C.
Lens Color
Position “A”
A.
No Lens
B.
Red
C.
Green
D.
Amber
E.
Clear
Position “C”
A.
No Lens
B.
Red
C.
Green
D.
Amber
E.
Clear
Dependent Light
ON in position “A”
Wired to terms
1
& 3
C.
Dependent Light
ON in position “A”
Wired to terms
1
& 3
Dependent Light
ON in position “C”
Wired to terms
2
& 4
D.
E.
G.
Independent Light
ON in position “C”
Wired to terms
2
& 4
F.
Dependent Light
ON in position “A”
Wired to terms
1
& 3
Independent Light
ON in position “C”
Wired to terms 3 &
4
G.
D.
H.
J.
NOTES:
• No momentary switches with dependent lights.
• Neon lamps only to be coded with clear or amber
lenses.
• LED lenses must be clear or same color as LED.
• No dependent light in OFF position.
• All legends printed on actuators without lens(es)
will be white except actuator codes C, F, J, M & R.
• All legends printed on lenses will be white except
on clear lens(es) will be black.
Independent Light
at position “A”
Wired to terms 3 &
4
H.
K.
Independent Light
at position “A”
Wired to terms
3
& 4
Dependent Light
ON in position “C”
Wired to terms
2
& 4
E.
L.
Independent Light
at position “C”
Wired to terms 3 &
4
M.
N.
D
= Dependent Light
I
= Independent Light
NOTES:
• LED anode (+) terminal number shown in
bold.
• Light on OFF side must be independent.
• Contact factory for multiple light types in the
same switch.
P.
R.
K1 panel plugs available as shown on page 167.
148
OTTO Full Line Catalog
Specifications Subject To Change Without Notice
SEALED, ILLUMINATED ROCKER SWITCHES
LOW COST, SNAP-IN ROCKER FOR WET & DUSTY ENVIRONMENTS
SNAP-IN
ROCKERS
K1
ROCKER SWITCHES
Specifications Subject To Change Without Notice
www.ottoexcellence.com
149
Introduction to the Switching Power Supply Design Process
Introduction to the Switching Power Supply Design Process...
tonytong Power technology
How to crack Eplan2.1 in Windows 7
[font=宋体][size=3][color=#000000]It took me a long time to install EPLAN P82.1 successfully. Let me share the installation method with you. Download the word document in the attachment. [/color][/size]...
postlily Industrial Control Electronics
After setting up mg323 gprs, use AT^SICI? All the returned values are 0, and the ip is also 0. Please help me. Check the official process for initialization.
Check gprs attachment, it is already attached. Check and register to local network. Then set conType, GPRS0, apn to cmnet, srv and conId are also set. Then check SICI? The returned ip is 0. Please sol...
DnStart stm32/stm8
How to perform loopback test on Ethernet UDP through DDR3?
As shown in the figure, how does Ethernet UDP perform a loopback test through DDR3?...
LuJianchang FPGA/CPLD
ADI's smoke detector integrated solution based on ADPD188BI live data collection
Live broadcast collection Award-winning live broadcast: ADI's smoke detector integrated solution based on ADPD188BILive playback:Click to watchLive Documentation: Click to downloadLive QA: 1. What is ...
EEWORLD社区 Integrated technical exchanges
MC34063 heating and output solutions [Original reprint please indicate the source]
I have been working on the power supply of mc34063 recently, and I have encountered some problems... The circuits in the official datasheet manual: problems encountered in step-down, step-up, and pola...
atcee Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1229  2778  508  811  2356  25  56  11  17  48 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号