EEWORLDEEWORLDEEWORLD

Part Number

Search

231282516812

Description
RESISTOR, THIN FILM, 1 W, 1 %, 50 ppm, 6810 ohm, THROUGH HOLE MOUNT, AXIAL LEADED, ROHS COMPLIANT
CategoryPassive components    The resistor   
File Size178KB,13 Pages
ManufacturerVishay
Websitehttp://www.vishay.com
Environmental Compliance  
Download Datasheet Parametric View All

231282516812 Overview

RESISTOR, THIN FILM, 1 W, 1 %, 50 ppm, 6810 ohm, THROUGH HOLE MOUNT, AXIAL LEADED, ROHS COMPLIANT

231282516812 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Objectid1009752133
package instruction,
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresRATED AC VOLTAGE(V) :500
JESD-609 codee3
Manufacturer's serial numberMBE/SMA0414
Installation featuresTHROUGH HOLE MOUNT
Number of terminals2
Maximum operating temperature155 °C
Minimum operating temperature-55 °C
Package shapeTUBULAR PACKAGE
method of packingTR
Rated power dissipation(P)1 W
Rated temperature70 °C
GuidelineAEC-Q200
resistance6810 Ω
Resistor typeFIXED RESISTOR
surface mountNO
technologyTHIN FILM
Temperature Coefficient50 ppm/°C
Terminal surfaceMatte Tin (Sn)
Terminal shapeWIRE
Tolerance1%
Operating Voltage500 V
MBA/SMA 0204, MBB/SMA 0207, MBE/SMA 0414 - Professional
Vishay Beyschlag
Professional Thin Film Leaded Resistors
FEATURES
Available in standard version or CECC version
(approved according to EN 140101-806)
Advanced thin film technology
Power dissipation rating up to 1 W
Excellent overall stability: Class 0.25
Wide professional range: 0.22
Ω
to 22 MΩ
Lead (Pb)-free solder contacts
Pure tin plating provides compatibility with lead (Pb)-free
and lead containing soldering processes
Compliant to RoHS directive 2002/95/EC
AEC-Q200 qualified
DESCRIPTION
MBA/SMA 0204, MBB/SMA 0207 and MBE/SMA 0414
professional leaded thin film resistors are the general
purpose resistor for all fields of professional electronics
where reliability and stability is of major concern. Typical
applications include industrial, telecommunication and
medical equipment.
APPLICATIONS
Industrial
Telecommunication
Medical equipment
METRIC SIZE
DIN
CECC
0204
A
0207
B
0414
D
TECHNICAL SPECIFICATIONS
DESCRIPTION
CECC Size
Resistance Range
Resistance Tolerance
Temperature Coefficient
Operation Mode
Climatic Category (LCT/UCT/Days)
Rated Dissipation,
P
70
Operating Voltage,
U
max.
AC/DC
Film Temperature
Max. Resistance Change at
P
70
for Resistance Range,
ΔR/R
max., After:
1000 h
8000 h
225 000 h
Permissible Voltage Against Ambient
(Insulation):
1 Minute;
U
ins
Continuous
Failure Rate: FIT
observed
300 V
75 V
0.1 x 10
-9
/h
500 V
75 V
0.1 x 10
-9
/h
800 V
75 V
0.1 x 10
-9
/h
125
°C
Long term
55/125/56
0.25 W
200 V
155
°C
125
°C
Standard
55/155/56
0.4 W
MBA/SMA 0204
A
0.22
Ω
to 10 MΩ
MBB/SMA 0207
B
0.22
Ω
to 22 MΩ
± 5 %; ± 1 %; ± 0.5 %
± 50 ppm/K; ± 25 ppm/K
Long term
55/125/56
0.4 W
350 V
155
°C
125
°C
Standard
55/155/56
0.6 W
Long term
55/125/56
0.65 W
500 V
155
°C
Standard
55/155/56
1.0 W
MBE/SMA 0414
D
0.22
Ω
to 22 MΩ
1
Ω
to 332 kΩ
0.25 %
0.5 %
1.5 %
0.5 %
1.0 %
-
1
Ω
to 1 MΩ
0.25 %
0.5 %
1.5 %
0.5 %
1.0 %
-
1
Ω
to 2.4 MΩ
0.2 %
0.4 %
1.2 %
0.4 %
0.8 %
-
Notes
• MB_ series has been merged with the related SMA series to form one series “MB_/SMA__”
• These resistors do not feature a limited lifetime when operated within the permissible limits. However, resistance value drift increasing over
operating time may result in exceeding a limit acceptable to the specific application, thereby establishing a functional lifetime.
www.vishay.com
22
For technical questions, contact:
filmresistorsleaded@vishay.com
Document Number: 28766
Revision: 03-Mar-10
How to inspect the remote controllers during mass production?
How to ensure that the remote control can work reliably at a long distance? It is convenient to test at a close distance, but at a long distance, there are many factors such as blind spots and obstacl...
andyzw RF/Wirelessly
Given an SFR register address, how do I program to read and write this SFR register?
I can't find how to read and write SFR directly through the address of SFR. For example, I get an address of 0x80, which is the address of an SFR. How can I write a byte to this address or read the co...
colorcharge Embedded System
When using ftp to transfer files, it prompts 425 Can't open passive connection
When using Red Hat Enterprise Linux 6.3 to transfer files via FTP, the error 425 Can't open passive connection appears. How can I solve this problem?...
thinkcode Linux and Android
Compilation error
As shown below, an error message is obtained after compiling Error: this declaration has no storage class or type specifierWhat does this mean?...
zzbaizhi Microcontroller MCU
MSP430F449 internal FLASH operation, you can refer to it! You can also take a look if you don't need it!
MSP430F449_DATA FLASH Operation\45DB041.pdf.........................\TEST44X_dataflash(AT45DB041).c...
wuyanyanke Microcontroller MCU
Why isn't the website grayed out?
Why isn't the website grayed out?...
jiereliyi DIY/Open Source Hardware

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2662  797  2516  2082  666  54  17  51  42  14 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号