EEWORLDEEWORLDEEWORLD

Part Number

Search

2648LP/3A21308L110V3/3

Description
Rocker Switch, DPDT, Latched And Momentary, 10A, 12VDC, Quick Connect Terminal, Plain Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size230KB,8 Pages
ManufacturerAPEM
Environmental Compliance
Download Datasheet Parametric View All

2648LP/3A21308L110V3/3 Overview

Rocker Switch, DPDT, Latched And Momentary, 10A, 12VDC, Quick Connect Terminal, Plain Rocker Actuator, Panel Mount

2648LP/3A21308L110V3/3 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompli
ECCN codeEAR99
Actuator typePLAIN ROCKER
body width18.5 mm
body height28.1 mm
Body length or diameter32 mm
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@12VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)12 V
Electrical life10000 Cycle(s)
illuminationGREEN LAMP
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature125 °C
Minimum operating temperature-20 °C
method of packingBULK
surface mountNO
Switch actionLATCHED AND MOMENTARY
switch functionDPDT
Switch typeROCKER SWITCH
Termination typeQUICK CONNECT
Base Number Matches1
2600 series
Illuminated and non-illuminated rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max. at 1A 2VDC
Models for peak currents
• Insulation resistance : 1.000 MΩ min. at 500VDC
Models 2600SLH with silver cadmium oxide contacts
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
are discontinued. They will be replaced by switches
3.000 Vrms 50 Hz min. between terminals and metal panel
with silver tin oxide contacts.
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +125°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-49
FPGA several download methods.doc
FPGA several download methods.doc...
zxopenljx FPGA/CPLD
WinCE socket problem, urgent
After the socket is created, the handle value is 1. Is this normal? Before recv, select returns -1, but recv always returns -1. What is the reason? Thank you...
yanshen Embedded System
The screen of the 9B96 board purchased in the group has never lit up, and the backlight voltage is 5V. I am confused...
I participated in the group purchase with great expectations. I was so excited to get the 9B96 board, but the screen never lit up after powering on. I downloaded the new program many times and re-plug...
syaoraner Microcontroller MCU
Agilent Instruments for Testing Solar Arrays, Inverters and Fuel Cells
[b][color=#7a95d2]Agilent SAS (Solar Cell Simulator)[/color][/b] When you design new energy related products, you will need fast programmable voltage source/current source that can simulate the output...
安_然 Energy Infrastructure?
When posting, when inviting others to participate, can you directly write the names of multiple people and submit them together, which can save time
When posting, when inviting others to participate, can I directly write the names of multiple people and submit them together? This can save time. For example, the enthusiastic heroes who often answer...
深圳小花 Suggestions & Announcements
A brief discussion on how to learn Linux
A brief discussion on how to learn linux 1. Why should you learn linux? Of course, the most important thing is hobbies and interests! If you have to learn it, or don't like it at all, please don't was...
maker Linux and Android

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 787  733  2787  424  1129  16  15  57  9  23 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号