85/86 - 5/8 ” Square Single-Turn Panel Control with Rotary Switch
Potentiometer Specifications
Initial Electrical Characteristics
1
Conductive Plastic Element
Cermet Element
Standard Resistance Range
Linear Tapers (A, B, E, & H) ..................................................................(B & E) 1 K ohms to 1 megohm ............. (A & H) 100 ohms to 1 megohm
Audio Tapers (C, D, F, G, S, & T) .........................................................(D, G, S, & T) 1 K ohms to 1 megohm ... (C & F) 1 K ohms to 1 megohm
Total Resistance Tolerance .........................................................................±20 % or 10 % ...................................... ±10 % or 5 %
Absolute Minimum Resistance ...................................................................2 ohms maximum .................................. 2 ohms maximum
Operating Temperature Range ...................................................................-40 °C to +125 °C.................................. -40 °C to +125 °C
Storage Temperature Range ......................................................................-55 °C to +125 °C.................................. -55 °C to +125 °C
Temperature Coefficient Over Storage Temperature Range ......................±1,000 ppm/°C ...................................... ±150 ppm/°C
Vibration (Single Section) ...........................................................................15 G ....................................................... 15 G
Total Resistance Shift ...........................................................................±2 % maximum ..................................... ±2 % maximum
Voltage Ratio Shift ................................................................................±5 % maximum ..................................... ±5 % maximum
Shock (Single Section) ...............................................................................30 G ....................................................... 30 G
Total Resistance Shift ...........................................................................±2 % maximum ..................................... ±2 % maximum
Voltage Ratio Shift ................................................................................±5 % maximum ..................................... ±5 % maximum
Total Resistance Shift ...........................................................................±10 % maximum ................................... ±5 % maximum
Rotational Life (No Load) ............................................................................100,000 cycles ...................................... 100,000 cycles
Total Resistance Shift ...........................................................................(Linear taper) 10 ohms or ..................... (All tapers) ±5 % TRS maximum
Moisture Resistance (MIL-STD-202, Method 103, Condition B)
Total Resistance Shift ...........................................................................(B & E tapers) ±10 % maximum ........... ±5 % maximum (all tapers)
IP Rating .....................................................................................................IP 40 ...................................................... IP 40
Starting and Running Torque (Non-Locking Bushings)
Single Section ................................................................................................................................................................. 0.14 to 1.06 N-cm (0.2 to 1.5 oz.-in.)
Dual Section .................................................................................................................................................................... 0.14 to 1.06 N-cm (0.2 to 1.5 oz.-in.)
Triple Section ................................................................................................................................................................... 0.35 to 1.41 N-cm (0.5 to 2.0 oz.-in.)
Quadruple Section .......................................................................................................................................................... 0.35 to 1.41 N-cm (0.5 to 2.0 oz.-in.)
Starting and Running Torque (Locking Bushings) ..................................................................................................... 0.14 to 2.82 N-cm (0.2 to 4.0 oz.-in.)
Shaft Locking Torque with Locknut @ 10 in-lb. (B & E Bushings) ........................................................................................................ 14 N-cm (20 oz-in.)
Mounting ...................................................................................................................................................................1.7-2.0 N-m (15-18 lb.-in.) maximum
Weight (Single Section).............................................................................................................................................................................. 21 grams maximum
(Each Additional Section) ...................................................................................................................................................................... 6 grams maximum
Terminals .......................................................................................................................................................................... Printed circuit terminals or J-Hooks
Soldering Condition .................................................................. Recommended hand soldering using Sn95/Ag5 no clean solder, 0.025 ” wire diameter.
Maximum temperature 399 °C (750 °F) for 3 seconds. No wash process to be used with no clean flux.
Marking.......................................................................... Manufacturer’s trademark, wiring diagram, date code and resistance, manufacturer’s part number
Ganging (multiple section potentiometers) ..................................................................................................................................................... 4 cup maximum
Hardware ...........................................One lockwasher and one mounting nut is shipped with each potentiometer, except where noted in the part number.
For dimensional drawings see pages 3 & 4.
For ordering information see page 5.
NOTE: Model 81/82 performance specifications do not apply to units subjected to printed circuit board cleaning procedures.
1At room ambient: +25 °C nominal and 50 % relative humidity nominal, except as noted.
*RoHS Directive 2002/95/EC Jan 27, 2003 including Annex.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications
81/82 - 5/8 ” Square Single-Turn Panel Control
85/86 - 5/8 ” Square Single-Turn Panel Control with Rotary Switch
Rotary Switch Specifications
Initial Electrical Characteristics
1
Contacts:
DPST ...............................................................................................................................................................................N.O/N.O.,N.C./N.C. or N.O./N.C.
DPDT ................................................................................................................................................................................2 N.O./N.C. (break before make)
Power Rating (Resistive Load):
DPST ............................................................................................................ 2 A @ 125 volts RMS-60 Hz or 2 A @ 28 VDC, 1 A @ 250 volts RMS-60 Hz
DPDT ........................................................................................................................................................... 1 A @ 125 volts RMS-60 Hz or 1 A @ 28 VDC
Operating Temperature Range ...........................................................................................................................................................................0 °C to +70 °C
Storage Temperature Range ........................................................................................................................................................................ -65 °C to +125 °C
Vibration (Dual Section) ....................................................................................................................................................................................................... 8 G
(Triple Section) .................................................................................................................................................................................................... 5 G
(Quadruple Section) ........................................................................................................................................................................................... 3 G
Contact Resistance ........................................................................................................................................................................ 10 milliohms maximum
Contact Bounce ......................................................................................................................................................................... 0.1 millisecond maximum
Shock (Dual Section) ......................................................................................................................................................................................................... 20 G
(Triple Section) ...................................................................................................................................................................................................... 15 G
(Quadruple Section) ............................................................................................................................................................................................. 10 G
Contact Resistance ........................................................................................................................................................................ 10 milliohms maximum
Contact Bounce ......................................................................................................................................................................... 0.1 millisecond maximum
Rotational Life ..................................................................................................................................................................................................... 25,000 cycles
Switch Actuating Torque (50% Duty cycle @ Rated Power Load) .................................................................................. 1.41 to 4.94 N-cm (2 to 7 oz.-in.)
Contact Resistance ...................................................................................................................................................................... 100 milliohms maximum
Moisture Resistance (MIL-STD-202, Method 106, Condition B)
Contact Resistance (0.1 VDC-10 mA) ............................................................................................................................................ 10 milliohms maximum
Switch Housing Material ................................................................................................................. High temperature, flame retardant, thermosetting plastic
Mechanical Characteristics
1
Actuating Torque (Each Section, Switch Module Only) ....................................................................................................... 3.53 to 10.6 N-cm (5 to 15 oz.-in.)
Running Torque (Out of Detent, 2-4 Module Assembly)..................................................................................................... 0.21 to 1.41 N-cm (0.3 to 2 oz.-in.)
Detent ..................................................................................................................................................................................................... CW or CCW standard
Contact Materials ..........................................................................................................................................................................Fine silver with gold overlay
Terminal Styles .................................................................................................................................................................................................. Solder lug only
Standard Orientation ..............................................................................................................................................................In-line with control terminals
Optional .......................................................................................................................................................................... Rotated 90 ° CCW from standard
Terminal Strength (Before and After Soldering Heat Exposure) .......................................................................................................... 0.9 Kg (2 lbs.) minimum
NOTE: Model 81/82 performance specifications do not apply to units subjected to printed circuit board cleaning procedures.
1At room ambient: +25 °C nominal and 50 % relative humidity nominal, except as noted.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications
The first program calls a VOID type function to convert an integer into a string outputvoid inttostring(int n,char string[]) {int i=0,j;while (n!=0){ string[i]='0'+n%10;i++;n/10;}string[i]='\0';for(j=...
I won't say much about threadX rtos. From the perspective of safety certification, it is enough to beat other rtos on the market. tx is also very convenient in porting, especially the support of ports...
STM32 provides a convenient firmware library, and users can complete serial port operations by calling limited APIs without understanding registers.
Upload two examples first, the examples run well on...
WinCE5 development question: How to get the path name of the PDA storage card? The directory name of each PDA storage card is different. How can I get it in the program? \Storage Card, \SDMMC, \Storag...
I just learned microcontrollers. I use VB as the host computer. I manually send 1-12 data. The first board uses the serial port to communicate with the computer and encodes each received data through ...
Emergency hand-held lamps powered by 6V maintenance-free batteries are widely used in rural areas. The charger used is a transformer step-down and single diode half-wave rectifier, and the charging...[Details]
1. System Structure
This system is a simulation system of indoor air-conditioning temperature/humidity control system. The data acquisition and control center collects temperature/humidity...[Details]
1. Introduction to CIF Board
Fieldbus integration based on PC system
Whether it is a master or a slave, fieldbus has won unanimous praise in the field of PC-based automation. For more...[Details]
Motors are important products that convert electrical energy into mechanical energy to achieve automation, and they are widely used in industrial control, medical electronics, white a...[Details]
Introduction
In industrial control, speed measurement is often required. Generally, a contact tachometer is used. This tachometer must be placed against the center of the shaft to measure. It...[Details]
Against the backdrop of global warming, energy conservation and emission reduction have become a global hotspot and focus, which has also sounded the clarion call for the take-off of the LED lighti...[Details]
Portable power applications are broad and varied. Products range from wireless sensor nodes with average power consumption of only a few microwatts to in-vehicle medical or data acquisition systems...[Details]
1 Introduction
Washing machines are an indispensable household appliance in the home, and they are developing very fast. Fully automatic washing machines are favored by everyone because of their con...[Details]
The biggest advantage of Profibus is that it is guaranteed by the stable international standard EN50170 and has been proven to be universal in practical applications. It has been widely used in man...[Details]
TMC428 is a stepper motor motion controller from TRINAMIC. It can reduce the workload of motor control software design and development costs. The 3-axis stepper motor drive control system based on ...[Details]
The programmable controller directly controls the stepper motor, which can significantly reduce the cost of the control system of the modular machine tool automatic production line. The article int...[Details]
Li/SOCl2 batteries (lithium sub-cells) have the advantages of high operating voltage, stable discharge voltage, wide operating temperature range and long storage life, and have been widely used in ...[Details]
1. Why do we need to do electromagnetic compatibility design for products?
Answer: To meet product functional requirements, reduce debugging time
,
make products meet the requirements o...[Details]
System Block Diagram
The system uses DSP56F826 chip as the core control module and CMOS digital image sensor chip. The image acquisition resolution can reach 640×480 pixels. When high-re...[Details]