• Transformer Coupled Across 70 ohms, Measured on Stub:
• BU-63147/157XX-XX0
• BU-63147X3-XX2 (Note 9)
Output Noise, Differential (Direct Coupled)
Output Offset Voltage, Transformer Coupled Across 70 ohms
Rise/Fall Time
• BU-63147/157X3
• BU-63147X4
LOGIC
V
IH
V
IL
I
IH
Tx
Data In
, Tx
Inhibit
, Rx
Strobe
I
IL
Tx
Data In
, Tx
Inhibit
, Rx
Strobe
V
OH
(Vcc=4.75V,I
OH
=max)
V
OL
(Vcc=4.75V,I
OH
=max)
I
OL
I
OH
6
18
20
-250
100
200
7
20
22
150
150
250
9
27
27
10
250
300
300
Vp-p
Vp-p
Vp-p
mVp-p, diff
mVp-p, diff
ns
ns
2.0
20
-100
2.4
0.4
3.4
-3.4
0.8
100
-20
V
V
µA
µA
V
V
mA
mA
POWER SUPPLY REQUIREMENTS
Voltages/Tolerances
• +5V
Current Drain (Total Hybrid)
BU-63147/157/XX-XX0
• Idle (Both Channels)
• 25% Transmitter Duty Cycle (One Channel)
• 50% Transmitter Duty Cycle (One Channel)
• 100% Transmitter Duty Cycle (One Channel)
BU-63147/X3-XX2
• Idle (Both Channels)
• 25% Transmitter Duty Cycle (One Channel)
• 50% Transmitter Duty Cycle (One Channel)
• 100% Transmitter Duty Cycle (One Channel)
4.75
5.0
80
199
286
455
80
210
308
500
5.25
100
229
348
535
100
240
370
580
V
mA
mA
mA
mA
mA
mA
mA
mA
Data Device Corporation
www.ddc-web.com
3
BU-63147
R-10/14-0
TABLE 1. BU-63147/157 SPECIFICATIONS (CONT.)
PARAMETER
POWER DISSIPATION (NOTE 10)
Total Hybrid
BU-63147/157/XX-XX0
• Idle (Both Channels)
• 25% Transmitter Duty Cycle (One Channel)
• 50% Transmitter Duty Cycle (One Channel)
• 100% Transmitter Duty Cycle (One Channel)
BU-63147/X3-XX2
• Idle (Both Channels)
• 25% Transmitter Duty Cycle (One Channel)
• 50% Transmitter Duty Cycle (One Channel)
• 100% Transmitter Duty Cycle (One Channel)
Hottest Die
BU-63147/157/XX-XX0
• Idle (One Channel)
• 25% Transmitter Duty Cycle (One Channel)
• 50% Transmitter Duty Cycle (One Channel)
• 100% Transmitter Duty Cycle (One Channel)
BU-63147/X3-XX2
• Idle (One Channel)
• 25% Transmitter Duty Cycle (One Channel)
• 50% Transmitter Duty Cycle (One Channel)
• 100% Transmitter Duty Cycle (One Channel)
THERMAL
• Thermal Resistance, Junction-to-Case, Hottest Die (θ
JC
)
• Operating Junction Temperature
• Storage Temperature
• Lead Temperature (soldering, 10 sec.)
PHYSICAL CHARACTERISTICS
Size
36-Pin DIP
36-Lead Flat pack
Weight
MIN
TYP
MAX
UNITS
0.4
0.65
0.73
0.88
0.4
0.7
0.84
1.1
0.2
0.43
0.59
0.78
0.2
0.48
0.7
1.00
0.5
0.8
1.04
1.28
0.5
0.85
1.15
1.50
0.25
0.6
0.84
1.13
0.25
0.65
0.95
1.35
12
150
150
+300
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
°C/W
°C
°C
°C
-55
-65
1.900 x .800 x .205
(48.26 x 20.32 x 5.21)
1.900 x .800 x .200
(48.26 x 20.32 x 5.08)
0.6
(17)
in.
(mm)
in.
(mm)
oz
(g)
Notes:
Notes 1 through 6 are applicable to the Receiver Differential Resistance and Differential Capacitance specifications:
(1) Specifications include both transmitter and receiver (assumed tied together externally).
(2) Impedance parameters are specified directly between pins TX/RX A(B) and TX/RX A(B) hybrid.
(3) It is assumed that all power and ground inputs to the hybrid are connected and that the hybrid case is connected to ground for the impedance measurement.
(4) The specifications are applicable for both unpowered and powered conditions.
(5) The specifications assume a 2 volt rms balanced, differential, sinusoidal input. The applicable frequency range is 75 kHz to 1 MHz.
(6) Minimum resistance and maximum capacitance parameters are guaranteed over the operating range, but are not tested.
(7) The Threshold Level, as referred to in this specification, is meant to be the maximum peak-to-peak voltage (measured on the data bus) that can be applied to the
receiver's input without causing the output to change from the OFF state.
(8) Assumes a common mode voltage within the frequency range of dc to 2 MHz, applied to pins of the isolation transformer on the stub side (either direct or transformer
coupled), and referenced to transceiver ground. Transformer must be a DDC recommended transformer or other transformer that provides an equivalent minimum
CMRR.
(9) MIL-STD-1760 requires minimum output voltage of 20 Vp-p on the stub connection. The -XX2 option is
not
available for the BU-63147X4 or BU-63157 versions.
(10) Power dissipation specifications assume a transformer coupled configuration, with external dissipation (while transmitting) of 0.14 watts for the active isolation trans-
former, 0.08 watts for the active coupling transformer, 0.45 watts for each of the two bus isolation resistors, and 0.15 watts for each of the two bus termination resistors.
(11) Assuming the use of isolation transformers with the turns ratios shown in Figure 3 and in the absence of common mode signal on the 1553 stub, this equates to a
nominal stub voltage of 38 Volts
PK-to-PK
transformer-coupled, or 53 Volts
PK-to-PK
direct-coupled.
Data Device Corporation
www.ddc-web.com
4
BU-63147
R-10/14-0
TABLE 2. BU-63157 RADIATION SPECIFICATIONS*
PART NUMBER
BU-63157X3
TOTAL DOSE
100 KRAD
SINGLE EVENT
LATCHUP
IMMUNE
INTRODUCTION
The BU-63147/157 is a dual redundant transmitter and receiver
packaged in a 36-pin DDIP or flat pack. It is directly compatible to
Harris 15530 encoder/decoder and has internal (factory preset)
threshold levels. The dual transceiver only requires +5V power
and conforms to MIL-STD-1553A and 1553B. For McAir compat-
ibility, versions are available with rise/fall times of 200 to 300
nsec.
Figure 3 illustrates the connection between a BU-63147/157
transceiver and a MIL-STD-1553 Data Bus. After transformer
isolating the transceiver, it can be either direct coupled (short
stub) or transformer coupled (long stub) to the Data Bus.
*Note: Radiation parameters specified on this data sheet are derived from initial
qualification testing by DDC and published data from ASIC manufacturers. These
devices have not been evaluated for compliance to the RHA requirements stipu-
lated in MIL-PRF-38534, Appendix G.
TABLE 3. HIGH RELIABILITY SCREENING OPTIONS
FOR BU-63157
ELEMENT EVALUATION
Visual Inspection:
Integrated Circuits
Transistor & Diodes
Passive Components
METHOD
TRANSMIT OPERATING MODE
MIL-STD-883, Method 2010 Condition A
MIL-STD-750, Method 2072 and 2073
MIL-STD-883, Method 2032 Class S
SEM Analysis for Integrated MIL-STD-883, Method 2018
Circuits
Element Evaluation:
Visual, Electrical, Wire
Bondability, 24-Hour
Stabilization Bake, 10
Temperature Cycles,
5000 g’s constant accelera-
tion, 240-Hour Powered
Burn-In and 1000-Hour Life
Test (Burn-In and 1000-
Hour Life Test are Only
Required for Active
Components.)
ASSEMBLY & TEST
Particle Impact Noise
Detection (PIND)
320-Hour Burn-In
(Standard on this device)
100% Non-Destructive
Wirebond Pull
(Standard on this device)
Radiographic (X-Ray)
Analysis
QCI TESTING
Extended Temperature
Cycling:
20 Cycles Including
Radiographic (X-Ray)
Testing
Moisture Content Limit of
5000 PPM
MIL-STD-883, Method 2020
Condition A
MIL-STD-883, Method 1015
The transmitter section accepts encoded TTL data and converts
it to phase-modulated bipolar form using a waveshaping network
and driver circuits. The driver outputs TX DATA OUT and TX DATA
OUT are transformer coupled to the Data Bus.
The transmitter output terminals can be put into a high imped-
ance state by setting INHIBIT high, or setting TX DATA IN and TX
DATA IN to the same logic level. The operating modes are shown
in TABLE 4.
The transceivers are able to operate in a “wraparound” mode.
This allows output data to be monitored by the receiver section
and returned to the decoder where it is checked for errors.
MIL-PRF-38534
TABLE 4. TRANSMIT OPERATING MODE
TX DATA IN
X
0
0
MIL-STD-883, Method 2023
1
1
MIL-STD-883, Method 2012
TX DATA IN
X
0
1
0
1
TX INHIBIT
H
X
L
L
X
DRIVER OUTPUT
OFF (NOTE)
OFF
TX DATA OUT ON,
TX DATA OUT OFF
TX DATA OUT ON,
TX DATA OUT OFF
OFF
NOTE: DRIVER OUTPUT terminals are in the high impedance mode during
The integration of the RF front end of GSM mobile phones has been continuously developing, from front-end modules (FEMs) to radio frequency (RF) transceiver modules. In fact, the front-end integration...
[i=s] This post was last edited by jameswangsynnex on 2015-3-3 19:58 [/i] Resistors, capacitors, crystals , diodes, Zener diodes, inductors, varactor diodes, crystals , triodes, field effect transisto...
The product is DEC2407 development board (LF2407A). Can the PWM3/PWM4 pair of waveforms be started after a specified time t after PWM1/PWM2 is started?The overall goal is to achieve two pairs of PWM w...
The core of a machine vision system is image acquisition and processing. All information comes from images, and image quality is crucial to the entire vision system. A good image can improve the st...[Details]
A parallel inverter consists of two thyristors (T1 and T2), a capacitor, a center-tapped transformer, and an inductor. The thyristors provide a current path, while the inductor L maintains a consta...[Details]
To understand why car engines need gearboxes, we must first understand the characteristics of different types of engines. An engine refers to a machine that can convert a form of energy into kineti...[Details]
In recent years, many people have switched to new energy vehicles, and this type of vehicle has indeed been highly sought after and is considered the future direction of automobile development, and...[Details]
On August 25th, SK Hynix announced that it has completed development and entered mass production of its 321-layer, 2Tb QLC NAND flash memory product. This achievement marks the world's first applic...[Details]
A multilevel inverter converts a DC signal into a multilevel staircase waveform. Instead of a straight positive-negative output waveform, the output waveform of a multilevel inverter alternates in ...[Details]
There are many motors that can use thyristor speed control, and they can be used in almost all industries. Various types of motors, such as fans, pumps, AC motors, DC motors, torque motors, single-...[Details]
According to Reuters, citing people familiar with the matter, British semiconductor design company Arm Holdings (NASDAQ:ARM) has hired Rami Sinno, head of Amazon's (NASDAQ:AMZN) artificial intellig...[Details]
Introduction: Traditionally, lead-acid batteries have primarily been used to provide backup power and power regulation based on location. In typical applications, the battery's actual use (discharg...[Details]
At present, the most troubling thing about pure electric vehicles as new energy sources is not only the range anxiety, but also the disadvantage of long charging time. At present, ternary lithium b...[Details]
The automotive transmission is the foundation of a vehicle's motion. The vehicle's drivetrain transfers engine power to the drive wheels, enabling the vehicle to move. The vehicle's drivetrain cons...[Details]
This series of articles aims to help readers have a brief understanding of the Hongke KPA Automation system and to quickly get started with MoDK, including: an introduction to Hongke KPA Automation...[Details]
Since entering the electronic components industry, I've learned that electronic components come in different packaging types. Some people have argued that different types of components may look the...[Details]
Which one has lower driving cost, electric vehicles or fuel vehicles? This is a topic of great concern to car users. Structurally, electric vehicles do not have mechanical transmission systems such...[Details]
The field of AI is constantly evolving. We are witnessing a profound shift from the era of "generative AI" to the era of "agent AI." This transformation has the potential to reshape industries an...[Details]