Fixed Resistor, Metal Foil, 1.75W, 191000ohm, 600V, 0.05% +/-Tol, -2,2ppm/Cel,
CategoryPassive components    The resistor   
File Size451KB,6 Pages
ManufacturerVishay
Websitehttp://www.vishay.com
Environmental Compliance
Download Datasheet Parametric View All

302075-7T191K00AB Overview

Fixed Resistor, Metal Foil, 1.75W, 191000ohm, 600V, 0.05% +/-Tol, -2,2ppm/Cel,

302075-7T191K00AB Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid851141121
Reach Compliance Codecompliant
ECCN codeEAR99
structureHermetically Sealed
JESD-609 codee3
Lead diameter0.64 mm
Lead length25.4 mm
Number of terminals4
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package diameter12.7 mm
Package length38.1 mm
Package form4 Terminals
method of packingBulk
Rated power dissipation(P)1.75 W
resistance191000 Ω
Resistor typeFIXED RESISTOR
seriesH(OTHER)
technologyMETAL FOIL
Temperature Coefficient-2,2 ppm/°C
Terminal surfaceTin (Sn)
Tolerance0.05%
Operating Voltage600 V
H Series
Vishay Foil Resistors
New Generation of Secondary Standards Hermetically Sealed High Precision Bulk
Metal
®
Foil Technology Resistors with TCR of ± 2 ppm/°C, Tolerance of ± 0.001 % and
Load Life Stability of ± 0.005 % (Metrology, Laboratory, Instrumentation, Industrial)
FEATURES
Temperature coefficient of resistance (TCR):
± 2 ppm/°C typical (- 55 °C to + 125 °C, + 25 °C
ref.).
For
ultra
high
performances
(instrumentation and metrology) please refer to
the last page
Resistance range: 5
Ω
to 1.84 MΩ (higher or
lower values of resistance available)
Vishay Foil resistors are not restricted to standard values;
specific “as required” values can be supplied at no extra
cost or delivery (e.g. 1K2345 vs. 1K)
Power rating: 0.3 W to 2.5 W at + 25 °C (depending on
model - see table 2)
Tolerance: to ± 0.001 % (10 ppm)
Load life stability to ± 0.002 % (20 ppm) at 25 °C, 2000 h
at rated power
Load life stability can be considerably improved
through in-house stabilization
Shelf life stability: ± 2 ppm for at least 6 years
(unaffected by humidity)
Electrostatic discharge (ESD) up to 25 000 V
Rise time: 1 ns effectively no ringing
Thermal stabilization time < 1 s (nominal value achieved
within 10 ppm of steady state value)
Current noise: 0.010 µV
RMS
/V of applied voltage (< - 40 dB)
Thermal EMF: 0.05 µV/°C typical
Voltage coefficient: < 0.1 ppm/V
Non-inductive: < 0.08 µH
Non-inductive, non-capacitive design
Non hot spot design
Terminal finish available: lead (Pb)-free or tin/lead alloy
Impervious to harmful environments - oil-filled
Compliant to RoHS directive 2002/95/EC
Prototype quantities available in just 5 working days
or sooner. For more information, please contact
foil@vishaypg.com
For better performances (values, TCR, tolerance, stability),
please see the HZ series
INTRODUCTION
The H series resistors are oil-filled, hermetically sealed ultra
precision resistors and are used as secondary standards for
metrology applications.
The hermetic sealing eliminates the ingress of moisture and
oxygen, while the oil acts as a thermal conductor, thus
eliminating the long-term degradation elements of unsealed
resistors, while at the same time allowing the device to
accept short periods of overload without degradation.
Vishay’s Bulk Metal
®
Foil outperforms all other resistor
technologies available today for applications that require
precision and stability. When combined with the hermetic
sealing and oil filling, the H series resistors become
the most
precise and stable resistors available.
With accuracies of 0.001 %, a resistance range from 5
Ω
to 1.84 MΩ, and long term shelf life of less than 2 ppm,
these devices are virtually secondary standards that can be
carried in sets for daily or periodic calibration of factory
measurement equipment.
The H series is available with laboratory and metrology
level precision and long-term stability with additional
in-house oriented processes such as: chip stabilization,
special TCR plotting, additional treatments for ultra
stability and special post manufacturing operations
(PMO). (Please refer to the last page)
TABLE 1 - TCR VS. RESISTANCE VALUE
RESISTANCE
VALUE (Ω)
100 to < 1M84
50 to < 100
5 to < 50
TYPICAL TCR AND MAX. SPREAD
(- 55 °C to + 125 °C, + 25 °C ref.)
(ppm/°C)
± 2 ± 2.5
± 2 ± 3.5
± 2 ± 4.5
FIGURE 1 - SHELF LIFE - VHA518-11
12K9 VS. QHE
1
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
- 0.1
0
100 200 300 400 500 600 700 800 900 1000
Note
• For maximum TCR < 1 ppm/°C, see VHP100 and contact
application engineering
* Pb containing terminations are not RoHS compliant, exemptions may apply
Resistance Change (ppm)
Time (Days)
Document Number: 63006
Revision: 23-Mar-10
For any questions, contact:
foil@vishaypg.com
www.foilresistors.com
1
TSP distributed control increases test speed and reduces test costs
TSP technology enhances instrument control by allowing users to use standard PC control or create embedded test scripts that execute on the microprocessor within the instrument. By using TSP test scri...
Jack_ma Test/Measurement
Please help look at this program!
#include#pragma vector = PORT1_VECTOR __interrupt void Port_1(void) { volatile unsigned int i; // volatileWhen programming the source code, do not use optimization for this variablefor (i = 0; i30000;...
Hsiang Microcontroller MCU
Orcad Capture CIS automatically numbers after deleting a component, and DRC appears when importing the netlist into Allegro
For example, I drew 10 resistors, numbered R1~R10, and the connections were already drawn in Allegro. Then I deleted R5 in the schematic, renumbered it automatically, and then imported it into the net...
ayu_ag PCB Design
Blood oxygen saturation is detected by receiving the energy ratio of infrared light and red light, and then it can be calculated by adding an algorithm. Then the heart rate...
Blood oxygen saturation is detected by receiving the energy ratio of infrared light and red light, and then it can be calculated by adding an algorithm. So how is heart rate detection achieved? What a...
QWE4562009 Discrete Device
ActiveSync installation error
I encountered an error when installing ActiveSync. The error message was "Error writing to file: C:\Program Files\Microsoft ActiveSync\wcesmgr.exe, please verify that you have access to the directory....
han0602 Embedded System
The 2450 board runs fine at 400M, but crashes when playing CMMB TV at 533M???
Dear hardware and software experts, this problem has puzzled me for a long time. Could you please analyze the reason? Can Shuiyan also help analyze it? The problem is this: We use Samsung's S3C2450 pl...
qiaoli Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2213  2354  2743  2446  1115  45  48  56  50  23 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号