Moisture Sensitivity Level (MSL) – This product is not Moisture Sensitive - MSL = 1
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
STANDARD SPECIFICATIONS:
Parameters
Frequency Range
Operation Mode
Operating Temperature
Storage Temperature
Frequency Tolerance @+25°C
Frequency Stability over the
operating temperature ( ref. to
+25°C)
Equivalent series resistance (R1)
Shunt capacitance (C0)
Load capacitance (CL)
Drive Level
Aging@25°C±3°C
Insulation Resistance
Drive level dependency (DLD),
minimum 7 points tested: from
1µW to 500µW.
0
-55
-50
-100
See table 1 below
Minimum
1.8432
Typical
Maximum
Units
MHz
1.8432MHz – 24.000MHz
24.01MHz – 66.00MHz
66.01MHz – 122.00MHz
122.01MHz – 160.00MHz
See options
See options
See options
Notes
160.000
Fundamental
3
rd
Overtone
5
th
Overtone
7
th
Overtone
+70
+125
+50
+100
ºC
ºC
ppm
ppm
Ω
7
pF
18
pF
100
1000
µW
±5
ppm
500
M
Ω
Change in frequency (Maximum - Minimum) over
DLD range < ±10ppm;
Change in ESR (Maximum - Minimum) over DLD
range < 25% of Max ESR value;
Maximum ESR over DLD range < Max ESR value.
See options
First year
@100Vdc±15V
Table 1
FREQUENCY (MHz)
1.8432-1.999
2.000-2.399
2.400-2.999
3.000-3.699
3.700-4.199
4.200-4.899
4.900-5.999
6.000-7.999
8.000-9.999
10.000-12.499
12.50-50.00
24.00-66.00
66.01-122.00
122.01-160.00
Operation Mode
ESR
(Ω)
max
750
550
350
200
100
70
50
40
35
30
25
40
80
120
HC49/U
Fundamental
HC49/U (3rd OT)
HC49/U (5th OT)
HC49/U (7th OT)
LLC
5101 Hidden Creek Lane Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sale please visit:
www.abracon.com
REVISED: 01.05.2017
ABRACON IS
ISO9001-2008
CERTIFIED
HC49/U CRYSTAL
AB
OPTIONS AND PART IDENTIFICATION:
(Left blank if standard)
Pb
RoHS/RoHS II Compliant
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
AB -
Frequency in MH z
Please specify the frequency
in x x .x x x x M Hz.
e .g . 14.3181MHz
MHz -
-
-
-
-
-
-
P a c k a g in g
Blank: Bulk (std.)
T: Tape & Reel
(For MJ option only)
Q u a lit y F a c t o r * * *
Minimum
QXXXk
Value
L o a d Capacit anc e (pF)
Please specify CL
(Minimum 10 pF) in pF or
S fo r series
Custo m E SR if other
than st a n d a r d
R□
□: Specify
a value in
Ω
(e .g .: R40)
Operating Temp.
A: -10°C ~ + 60° C
B: -20°C ~ + 70° C
C: -30°C ~ + 70° C
N: -30°C ~ + 85° C
D: -40°C ~ + 85° C
Valu e Added
I
V
QXX
MJ
Operation Mode
Fund. AT > 24MHz
F
FB
O
Freq. Tolerance
1: ± 10 pp m
7: ± 15 pp m
2: ± 20 ppm
3: ± 25 ppm
4: ± 30 ppm
Freq . St abilit y
Option s fo r A T -
Cut only *
U * * : ± 1 0 p pm
G: ± 15 ppm
X: ± 20 ppm
W : ± 25 ppm
Y: ± 30 ppm
H: ± 35 ppm
Z: ± 5 0 p pm
Table 2
CODES
Q45
Q40
Q35
Q30
Q25
Q20
Q15
Q10
Q115
TRIMMED L in(mm)
0.45 (11.43)
0.40 (10.16)
0.35 (8.89)
0.30 (7.62)
0.25 (6.35)
0.20 (5.08)
0.15 (3.81)
0.10 (2.54)
0.115 (2.92)
NOTE: Use appropriat e code numbers for
other trimmed lengths not liste d.
(e.g. Q14 for 0.14 inch (3.55 mm))
Fund. BT>24MHz
3rd OT>66MHz
Insulator Tab
Vinyl Sleeve
T rimmed lea ds
See Ta ble 2
Metal jacket
NOTE:
*:Fr equency Stability ± 100
ppm max at -10 to +60C only
for BT cut.
** : -10 to +60C only.
*** : Quality factor must be
ac companied by a k value
LLC
5101 Hidden Creek Lane Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sale please visit:
www.abracon.com
REVISED: 01.05.2017
ABRACON IS
ISO9001-2008
CERTIFIED
HC49/U CRYSTAL
AB
OUTLINE DRAWING:
Insulator Tab
For Option I
Pb
RoHS/RoHS II Compliant
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
Vinyl Sleeve
For Option V
Dimensions: inch (mm)
LLC
5101 Hidden Creek Lane Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sale please visit:
www.abracon.com
REVISED: 01.05.2017
ABRACON IS
ISO9001-2008
CERTIFIED
HC49/U CRYSTAL
AB
OUTLINE DIMENSION CONTD...
Metal Jacket Formed Leads
For Option MJ
Pb
RoHS/RoHS II Compliant
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
T 1,000 pcs/reel
Dimensions: mm
TAPE & REEL:
T: 1,000 pcs/reel
Tape and reel packaging applies only to MJ (metal jacket) option
E
1.75±0.10
E2
22.25 MIN.
F
11.5±0.10
P2
2.00±0.10
ØD0
1.50±0.10
P0
4.00±0.10
W
24.00±0.30
Dimensions: mm
ATTENTION:
Abracon products are COTS – Commercial-Off-The-Shelf products; suitable for Commercial, Industrial and, where designated, Automotive Applications.
Abracon’s products are not specifically designed for Military, Aviation, Aerospace, Life-dependant Medical applications or any application requiring high reliability where
component failure could result in loss of life and/or property. For applications requiring high reliability and/or presenting an extreme operating environment, written consent and
authorization from Abracon is required. Please contact Abracon for more information.
I am a novice. How can I deploy an EVC program to a PDA? When I run the program on EVC, I get an error message "Cannot execute program". Can you please help me? I don't know why....
[backcolor=rgb(222, 240, 251)][size=5]I downloaded a .lib file from the official website, but when I opened it, it showed no model. I don’t know what’s going on. I want to ask if any forum friends hav...
I would like to post my experience and feelings about using Actel or the problems I encountered during the development process here. I don't know how to post now. I will upload some information about ...
In order to prevent traffic accidents, when the intelligent detection device of the car detects danger ahead, it must send a warning message to the driver. The voice alarm clearly reminds the drive...[Details]
This article discusses how to use an ultra-low-power RF transceiver chip from Zarlink Semiconductor for pacemakers, neurostimulators, drug pumps, and other such implantable medical devices to achiev...[Details]
Radio Frequency Identification (RFID) technology is a non-contact automatic identification technology that uses wireless radio frequency communication. Compared with the currently widely used barco...[Details]
With the continuous improvement of living standards and the increase in the proportion of urban aging, the household use of medical electronic equipment has gradually become a trend. Among them, the...[Details]
Keeping the heart environment compact and warm is beneficial in most cases, but it’s another story for electronic heart scanners. When GE Healthcare was designing a scanner that was said to be the fas...[Details]
At present, a hot spot for the research and development of hearing aids abroad is concentrated in China. To be more precise, it is based on the research of Chinese language and speech, and the deve...[Details]
As the application scope of medical equipment expands from hospitals to emergency response and home medical environments, its mobility will be determined by many factors. In addition, medical equip...[Details]
As the price of readers and tags decreases and the global market expands, the application of radio frequency identification (RFID) is increasing day by day. Tags can be powered by readers (passive ...[Details]
WiMax technology needs to demonstrate its advantages in specific application scenarios in order to gain market recognition, which requires application testing to measure system performance para...[Details]
The overcurrent and overheating coordinated protection technology implemented by polymer positive temperature coefficient devices (PPTC) can protect motors, controllers and electronic components in...[Details]
When you hear the word digital TV, you may feel fresh and excited, but when it comes to what digital TV is and what it can bring us, you may still be confused. You must be very eager to understa...[Details]
There are many ways to attenuate signals. The most commonly used method is to divide the voltage using resistors. The common circuits are as follows:
Oscilloscope pre-stage attenuation c...[Details]
Preface
In recent years, many compact portable electronic products have been developed, such as mobile phones, digital cameras, MP3, MP4, PDA, GPS and DVD, etc. They are not only small in size...[Details]
In today's world, terrorism poses a severe challenge to social development, national stability and human progress. "Terrorism, political corruption and environmental pollution" are known as the thr...[Details]