85/86 - 5/8 ” Square Single-Turn Panel Control with Rotary Switch
Potentiometer Specifications
Initial Electrical Characteristics
1
Conductive Plastic Element
Cermet Element
Standard Resistance Range
Linear Tapers (A, B, E, & H) ..................................................................(B & E) 1 K ohms to 1 megohm ............. (A & H) 100 ohms to 1 megohm
Audio Tapers (C, D, F, G, S, & T) .........................................................(D, G, S, & T) 1 K ohms to 1 megohm ... (C & F) 1 K ohms to 1 megohm
Total Resistance Tolerance .........................................................................±20 % or 10 % ...................................... ±10 % or 5 %
Absolute Minimum Resistance ...................................................................2 ohms maximum .................................. 2 ohms maximum
Operating Temperature Range ...................................................................-40 °C to +125 °C.................................. -40 °C to +125 °C
Storage Temperature Range ......................................................................-55 °C to +125 °C.................................. -55 °C to +125 °C
Temperature Coefficient Over Storage Temperature Range ......................±1,000 ppm/°C ...................................... ±150 ppm/°C
Vibration (Single Section) ...........................................................................15 G ....................................................... 15 G
Total Resistance Shift ...........................................................................±2 % maximum ..................................... ±2 % maximum
Voltage Ratio Shift ................................................................................±5 % maximum ..................................... ±5 % maximum
Shock (Single Section) ...............................................................................30 G ....................................................... 30 G
Total Resistance Shift ...........................................................................±2 % maximum ..................................... ±2 % maximum
Voltage Ratio Shift ................................................................................±5 % maximum ..................................... ±5 % maximum
Total Resistance Shift ...........................................................................±10 % maximum ................................... ±5 % maximum
Rotational Life (No Load) ............................................................................100,000 cycles ...................................... 100,000 cycles
Total Resistance Shift ...........................................................................(Linear taper) 10 ohms or ..................... (All tapers) ±5 % TRS maximum
Moisture Resistance (MIL-STD-202, Method 103, Condition B)
Total Resistance Shift ...........................................................................(B & E tapers) ±10 % maximum ........... ±5 % maximum (all tapers)
IP Rating .....................................................................................................IP 40 ...................................................... IP 40
Starting and Running Torque (Non-Locking Bushings)
Single Section ................................................................................................................................................................. 0.14 to 1.06 N-cm (0.2 to 1.5 oz.-in.)
Dual Section .................................................................................................................................................................... 0.14 to 1.06 N-cm (0.2 to 1.5 oz.-in.)
Triple Section ................................................................................................................................................................... 0.35 to 1.41 N-cm (0.5 to 2.0 oz.-in.)
Quadruple Section .......................................................................................................................................................... 0.35 to 1.41 N-cm (0.5 to 2.0 oz.-in.)
Starting and Running Torque (Locking Bushings) ..................................................................................................... 0.14 to 2.82 N-cm (0.2 to 4.0 oz.-in.)
Shaft Locking Torque with Locknut @ 10 in-lb. (B & E Bushings) ........................................................................................................ 14 N-cm (20 oz-in.)
Mounting ...................................................................................................................................................................1.7-2.0 N-m (15-18 lb.-in.) maximum
Weight (Single Section).............................................................................................................................................................................. 21 grams maximum
(Each Additional Section) ...................................................................................................................................................................... 6 grams maximum
Terminals .......................................................................................................................................................................... Printed circuit terminals or J-Hooks
Soldering Condition .................................................................. Recommended hand soldering using Sn95/Ag5 no clean solder, 0.025 ” wire diameter.
Maximum temperature 399 °C (750 °F) for 3 seconds. No wash process to be used with no clean flux.
Marking.......................................................................... Manufacturer’s trademark, wiring diagram, date code and resistance, manufacturer’s part number
Ganging (multiple section potentiometers) ..................................................................................................................................................... 4 cup maximum
Hardware ...........................................One lockwasher and one mounting nut is shipped with each potentiometer, except where noted in the part number.
For dimensional drawings see pages 3 & 4.
For ordering information see page 5.
NOTE: Model 81/82 performance specifications do not apply to units subjected to printed circuit board cleaning procedures.
1At room ambient: +25 °C nominal and 50 % relative humidity nominal, except as noted.
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications
81/82 - 5/8 ” Square Single-Turn Panel Control
85/86 - 5/8 ” Square Single-Turn Panel Control with Rotary Switch
Rotary Switch Specifications
Initial Electrical Characteristics
1
Contacts:
DPST ...............................................................................................................................................................................N.O/N.O.,N.C./N.C. or N.O./N.C.
DPDT ................................................................................................................................................................................2 N.O./N.C. (break before make)
Power Rating (Resistive Load):
DPST ............................................................................................................ 2 A @ 125 volts RMS-60 Hz or 2 A @ 28 VDC, 1 A @ 250 volts RMS-60 Hz
DPDT ........................................................................................................................................................... 1 A @ 125 volts RMS-60 Hz or 1 A @ 28 VDC
Operating Temperature Range ...........................................................................................................................................................................0 °C to +70 °C
Storage Temperature Range ........................................................................................................................................................................ -65 °C to +125 °C
Vibration (Dual Section) ....................................................................................................................................................................................................... 8 G
(Triple Section) .................................................................................................................................................................................................... 5 G
(Quadruple Section) ........................................................................................................................................................................................... 3 G
Contact Resistance ........................................................................................................................................................................ 10 milliohms maximum
Contact Bounce ......................................................................................................................................................................... 0.1 millisecond maximum
Shock (Dual Section) ......................................................................................................................................................................................................... 20 G
(Triple Section) ...................................................................................................................................................................................................... 15 G
(Quadruple Section) ............................................................................................................................................................................................. 10 G
Contact Resistance ........................................................................................................................................................................ 10 milliohms maximum
Contact Bounce ......................................................................................................................................................................... 0.1 millisecond maximum
Rotational Life ..................................................................................................................................................................................................... 25,000 cycles
Switch Actuating Torque (50% Duty cycle @ Rated Power Load) .................................................................................. 1.41 to 4.94 N-cm (2 to 7 oz.-in.)
Contact Resistance ...................................................................................................................................................................... 100 milliohms maximum
Moisture Resistance (MIL-STD-202, Method 106, Condition B)
Contact Resistance (0.1 VDC-10 mA) ............................................................................................................................................ 10 milliohms maximum
Switch Housing Material ................................................................................................................. High temperature, flame retardant, thermosetting plastic
Mechanical Characteristics
1
Actuating Torque (Each Section, Switch Module Only) ....................................................................................................... 3.53 to 10.6 N-cm (5 to 15 oz.-in.)
Running Torque (Out of Detent, 2-4 Module Assembly)..................................................................................................... 0.21 to 1.41 N-cm (0.3 to 2 oz.-in.)
Detent ..................................................................................................................................................................................................... CW or CCW standard
Contact Materials ..........................................................................................................................................................................Fine silver with gold overlay
Terminal Styles .................................................................................................................................................................................................. Solder lug only
Standard Orientation ..............................................................................................................................................................In-line with control terminals
Optional .......................................................................................................................................................................... Rotated 90 ° CCW from standard
Terminal Strength (Before and After Soldering Heat Exposure) .......................................................................................................... 0.9 Kg (2 lbs.) minimum
NOTE: Model 81/82 performance specifications do not apply to units subjected to printed circuit board cleaning procedures.
1At room ambient: +25 °C nominal and 50 % relative humidity nominal, except as noted.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications
[i=s]This post was last edited by paulhyde on 2014-9-15 09:21[/i] The speed of a stepper motor can be changed by rotating the motor shaft in steps . The internal comparison unit calculates the pulse n...
Recently, I need to design a Camera application using DirectShow. In order to beautify the interface, I want to expand some components. When expanding CMenu, I have constant troubles. First, I found t...
In order to facilitate communication and discussion, as the moderator of this forum, I have specially established a QQ exchange group. The group number is: 32914962. Welcome everyone to join! Don’t fo...
I want to learn embedded systems recently and plan to buy a board. Which one is more suitable for beginners? Arm11, Arm9, or A8. They seem to be about the same price and have a lot of information. Ple...
When the material is insufficient and there is no fault, press the start button, belt 3 starts, belt 2 starts after 5 seconds, belt 1 starts after another 5 seconds, the discharge valve opens, and the...
1. Several nouns
ABI:
The specifications that an executable file must follow in order to run in a specific execution environment;
Separately generated relocatabl...[Details]
To enable real-time monitoring of home security and automatically dial a number for voice prompts or send text messages when an alarm occurs, a GPRS-based embedded telephone alarm system was design...[Details]
Whether it is an electric car or an ordinary fuel car, for the vast majority of car buyers, the final cost of use is what they care about most. For fuel cars, how to save fuel is what drivers care ...[Details]
Today's security industry has entered the era of massive networking. Many enterprises, especially financial institutions, have established multi-level video surveillance networking platforms. Lever...[Details]
Recently, AstroBo Robot, a subsidiary of Chenxing Automation, launched a new mobile collaborative palletizing product. Leveraging an omnidirectional mobile chassis, an intelligent scheduling system...[Details]
On August 21st, Zhiyuan Robotics revealed at its first partner conference that it expects shipments to reach thousands of units this year and tens of thousands next year. The company hopes to reach...[Details]
The automotive industry in 2025 is undergoing a thorough intelligent reshuffle.
Geely wants to make changes in the field of AI cockpits: in the future, there will be no traditional smart...[Details]
To improve the lateral active safety of intelligent connected vehicles, the identification and definition of unexpected functional safety scenarios for the EPS (Electronic Steering System) ...[Details]
Tools/Materials
Yitong Chuanglian MODBUS to PROFIBUS Gateway YT-PB-03
Siemens s7-300
This article describes how to configure the YT-PB-03 MODBUS to PROFIBUS gat...[Details]
introduction
Inverter air conditioners are a trend in the current era and have gradually become commonplace in countless households. Beyond their basic cooling and heating functions, air condi...[Details]
The evolution of high-speed networks remains guided by the same core objectives: increasing data rates, reducing latency, improving reliability, lowering power consumption, and maintaining or exten...[Details]
When we pick up an unfamiliar object, the first thing we want to know is what it actually does. A drive shaft, as the name suggests, is a shaft that transmits power. It's the transmission medium th...[Details]
With the global number of new energy vehicles expected to exceed 45 million by 2025, the performance boundaries of battery management systems are being reshaped.
Infineon Technologies
'
...[Details]
Relying on Zena CSS and Arm's complete partner ecosystem, we will accelerate the implementation of autonomous driving.
Close your eyes and imagine yourself getting into your car, rea...[Details]
Currently, PLCs are widely used in various industries, including special machine tools, machine tools, control systems, building automation, steel, petrochemicals, electricity, building materials, ...[Details]