EEWORLDEEWORLDEEWORLD

Part Number

Search

2641LP/3A23601L24V/3

Description
Rocker Switch, DPST, Latched, 15A, 12VDC, Quick Connect Terminal, Concave Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size230KB,8 Pages
ManufacturerAPEM
Environmental Compliance
Download Datasheet Parametric View All

2641LP/3A23601L24V/3 Overview

Rocker Switch, DPST, Latched, 15A, 12VDC, Quick Connect Terminal, Concave Rocker Actuator, Panel Mount

2641LP/3A23601L24V/3 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompli
ECCN codeEAR99
Actuator typeCONCAVE ROCKER
body width18.5 mm
body height28.1 mm
Body length or diameter32 mm
Contact (AC) maximum rated R load16A@250VAC
Maximum contact current (AC)16 A
Maximum contact current (DC)15 A
Contact (DC) maximum rated R load15A@12VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)12 V
Electrical life10000 Cycle(s)
illuminationRED LAMP
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature125 °C
Minimum operating temperature-20 °C
method of packingBULK
surface mountNO
Switch actionLATCHED
switch functionDPST
Switch typeROCKER SWITCH
Termination typeQUICK CONNECT
Base Number Matches1
2600 series
Illuminated and non-illuminated rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max. at 1A 2VDC
Models for peak currents
• Insulation resistance : 1.000 MΩ min. at 500VDC
Models 2600SLH with silver cadmium oxide contacts
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
are discontinued. They will be replaced by switches
3.000 Vrms 50 Hz min. between terminals and metal panel
with silver tin oxide contacts.
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +125°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-49
Use 3D device models to accurately create components
[i=s]This post was last edited by rain_noise on 2015-9-8 14:58[/i] [p=30, 2, left]This article is based on Alitum Designer 14.1.5. [/p][p=30, 2, left]Take the Oupin 9001-36201C00A as an example to int...
rain_noise PCB Design
Do I need to install anything else before installing Protel 99 SE?
Do I need to install anything else before installing Protel 99 SE?...
who11131517190 PCB Design
Principle and Application of C8051 Single Chip Microcomputer
Principle and Application of C8051 Single Chip Microcomputer...
wangwei20060608 51mcu
【Atmel SAM R21】Optimization of LWMESH handwriting
[i=s]This post was last edited by ljj3166 on 2015-1-27 14:39[/i] [size=3][b]I have a basic understanding of lightweight MESH network[/b][/size] [size=3][b]I have built a simple wireless handwriting di...
ljj3166 Microchip MCU
Seeking solution
[table=98%] [tr][td][float=right] [/float] [align=center][color=rgb(153, 153, 153)][size=12px]This post was last edited by giant_bird on 2014-3-7 17:24[/size][/color][/align] The rest of the circuit w...
请问请问二人若 ADI Reference Circuit
Some subway stations in London have codes on their steps!
[size=5][color=#000000][backcolor=lightblue]The designer of the London Underground steps may be a programmer... [/backcolor][/color][/size][backcolor=lightblue][font=Arial, "][size=5][color=#000000]So...
qwqwqw2088 Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2587  1773  2716  123  15  53  36  55  3  1 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号