EEWORLDEEWORLDEEWORLD

Part Number

Search

BC03YA1R2CZB6SA3

Description
Ceramic Capacitor, Multilayer, Ceramic, 16V, 20.8333% +Tol, 20.8333% -Tol, C0G, 30ppm/Cel TC, 0.0000012uF, Surface Mount, 0603, CHIP
CategoryPassive components    capacitor   
File Size141KB,8 Pages
ManufacturerAVX
Download Datasheet Parametric View All

BC03YA1R2CZB6SA3 Overview

Ceramic Capacitor, Multilayer, Ceramic, 16V, 20.8333% +Tol, 20.8333% -Tol, C0G, 30ppm/Cel TC, 0.0000012uF, Surface Mount, 0603, CHIP

BC03YA1R2CZB6SA3 Parametric

Parameter NameAttribute value
Objectid145116016174
package instruction, 0603
Reach Compliance Codeunknown
ECCN codeEAR99
capacitance0.0000012 µF
Capacitor typeCERAMIC CAPACITOR
dielectric materialsCERAMIC
high0.9 mm
JESD-609 codee0
length1.6 mm
Installation featuresSURFACE MOUNT
multi-layerYes
negative tolerance20.8333%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package formSMT
method of packingWaffle Pack
positive tolerance20.8333%
Rated (DC) voltage (URdc)16 V
size code0603
surface mountYES
Temperature characteristic codeC0G
Temperature Coefficient-/+30ppm/Cel ppm/°C
Terminal surfaceTin/Lead (Sn/Pb)
Terminal shapeWRAPAROUND
width0.81 mm
COTS Plus - BC Series
General Specifications
GENERAL DESCRIPTION
Extended range MLCCs for avionic, defense, and space applications have
been available from AVX for many years, typically to customer specification
control documents. The COTS PLUS - BC series now consolidates the main
test options into standard catalog offerings, eliminating the need to generate
custom specifications for each application. Key test options from MIL-PRF-
55681 are applied to BME and PME devices in NP0 and X7R temperature
characteristic dielectrics.
PRODUCT ADVANTAGES
• Higher CV capability than standard PME
• BME and PME technology
• Voltage Range up to 500V
APPLICATIONS
Defense/Aerospace
• Extended Range MLCC for all Applications
• Low weight/payload, small footprint
• Low Voltage Ratings to Maximize Capacitance for High Speed Decoupling
HOW TO ORDER
BC
Series
03
Size
02 = 0402
03 = 0603
05 = 0805
06 = 1206
10 = 1210
12 = 1812
13 = 1825
5
C
102
Capacitance
Code (In pF)
2 Sig. Digits +
Number of
Zeros
K*
Z
T
9
AA
1
Extened Test Level
0 = Not Applicable
1 = DPA IAW EIA-469
2 = 85/85 @ RV for 96 hours
3 = DPA and 85/85 @ RV
Dielectric
Voltage
Z = 10V A = C0G (NP0)
Y = 16V C = X7R
3 = 25V
5 = 50V
1 = 100V
2 = 200V
V = 250V
7 = 500V
Capacitance
Failure Rate
Termination
Tolerance
Z = COTS Plus T = 100% TN
B = ±.10 pF
B = Tin/Lead
C = ±.25 pF
(5% min Lead)
D = ±.50 pF
J = Tin/Lead (60/40)
F = ±1% (≥ 10 pF)
G = ±2% (≥ 10 pF)
J = ±5%
K = ±10%
M = ±20%
* B, C & D tolerance for ≤10 pF values.
Packaging
Base Group A Test Level
1 = 7" T&R
AA = Group A per MIL-PRF-55681
3 = 13" T&R
SA = Group A per MIL-PRF-55681
6 = Waffle Pack
with SLDC
(SLDC = Single Lot Date Code)
9 = Bulk
CONFORMANCE TEST LEVELS
Base Group A Test Options
Voltage Conditioning IAW MIL-PRF-55681
Elevated IR Sample
Visual and Mechanical Inspection
Solderability
Single Lot Date Code (SLDC)
Group A Data Summary
AA
SA
Extended Test Options
Not Applicable
DPA IAW EIA-469
85°C/85% RH @ Rated Voltage / 96 Hrs
DPA and 85/85 @ Rated Voltage
Code
0
1
2
3
081516
1
pwm brushless ESC N5065 motor
I bought an fvt brushless ESC, an N5065 motor, and used the PWM driver of STM32. Set the throttle range according to the instructions: ****************************************** First turn off the ESC...
liuw2010 Electronics Design Contest
Problems with converting VHDL integer to real
I want to convert integer type signal to real type. The program is as follows. This program reports an error in maxplus II: file standard.vhdl:Unsupported feature error:floating is not supported An er...
力量 Embedded System
XILINX EDK: Get data from the serial port
Hello everyone! I'm learning Xilinx EDK recently, and I'd like to ask you a question. First of all, the board I'm using is ML506, and the software is EDK 11.1. There is a "hello world" program in the ...
applelonger FPGA/CPLD
Breakpoint setting in CCS3.3
1. If breakpoints cannot be set during simulation under CCS3.3. You need to check your project configuration. Open Build Optins, and in Basic under the Complier dialog box, set Generate Debug to Full ...
ltbytyn Microcontroller MCU
Random Questions about Operational Amplifier Circuits
[If you don't understand, ask] What is the function of the op amp in the picture, or what type of op amp does it belong to? If the inductor L is removed, it is very similar to an integrating amplifier...
shaorc Analog electronics
What is the maximum number of sectors that can be read and written to a hard disk (including a USB flash drive) using the DeviceIoControl function?
When I write to a USB flash drive, the maximum number of sectors is 128, and when I write to a hard disk, the maximum number of sectors is 248. I would like to ask what determines the maximum number o...
conanwind Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2771  1153  195  933  1867  56  24  4  19  38 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号