Moisture Sensitivity Level (MSL) – This product is not Moisture Sensitive - MSL = 1
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
STANDARD SPECIFICATIONS:
Parameters
Frequency Range
Operation Mode
Operating Temperature
Storage Temperature
Frequency Tolerance @+25°C
Frequency Stability over the
operating temperature ( ref. to
+25°C)
Equivalent series resistance (R1)
Shunt capacitance (C0)
Load capacitance (CL)
Drive Level
Aging@25°C±3°C
Insulation Resistance
Drive level dependency (DLD),
minimum 7 points tested: from
1µW to 500µW.
0
-55
-50
-100
See table 1 below
Minimum
1.8432
Typical
Maximum
Units
MHz
1.8432MHz – 24.000MHz
24.01MHz – 66.00MHz
66.01MHz – 122.00MHz
122.01MHz – 160.00MHz
See options
See options
See options
Notes
160.000
Fundamental
3
rd
Overtone
5
th
Overtone
7
th
Overtone
+70
+125
+50
+100
ºC
ºC
ppm
ppm
Ω
7
pF
18
pF
100
1000
µW
±5
ppm
500
M
Ω
Change in frequency (Maximum - Minimum) over
DLD range < ±10ppm;
Change in ESR (Maximum - Minimum) over DLD
range < 25% of Max ESR value;
Maximum ESR over DLD range < Max ESR value.
See options
First year
@100Vdc±15V
Table 1
FREQUENCY (MHz)
1.8432-1.999
2.000-2.399
2.400-2.999
3.000-3.699
3.700-4.199
4.200-4.899
4.900-5.999
6.000-7.999
8.000-9.999
10.000-12.499
12.50-50.00
24.00-66.00
66.01-122.00
122.01-160.00
Operation Mode
ESR
(Ω)
max
750
550
350
200
100
70
50
40
35
30
25
40
80
120
HC49/U
Fundamental
HC49/U (3rd OT)
HC49/U (5th OT)
HC49/U (7th OT)
LLC
5101 Hidden Creek Lane Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sale please visit:
www.abracon.com
REVISED: 01.05.2017
ABRACON IS
ISO9001-2008
CERTIFIED
HC49/U CRYSTAL
AB
OPTIONS AND PART IDENTIFICATION:
(Left blank if standard)
Pb
RoHS/RoHS II Compliant
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
AB -
Frequency in MH z
Please specify the frequency
in x x .x x x x M Hz.
e .g . 14.3181MHz
MHz -
-
-
-
-
-
-
P a c k a g in g
Blank: Bulk (std.)
T: Tape & Reel
(For MJ option only)
Q u a lit y F a c t o r * * *
Minimum
QXXXk
Value
L o a d Capacit anc e (pF)
Please specify CL
(Minimum 10 pF) in pF or
S fo r series
Custo m E SR if other
than st a n d a r d
R□
□: Specify
a value in
Ω
(e .g .: R40)
Operating Temp.
A: -10°C ~ + 60° C
B: -20°C ~ + 70° C
C: -30°C ~ + 70° C
N: -30°C ~ + 85° C
D: -40°C ~ + 85° C
Valu e Added
I
V
QXX
MJ
Operation Mode
Fund. AT > 24MHz
F
FB
O
Freq. Tolerance
1: ± 10 pp m
7: ± 15 pp m
2: ± 20 ppm
3: ± 25 ppm
4: ± 30 ppm
Freq . St abilit y
Option s fo r A T -
Cut only *
U * * : ± 1 0 p pm
G: ± 15 ppm
X: ± 20 ppm
W : ± 25 ppm
Y: ± 30 ppm
H: ± 35 ppm
Z: ± 5 0 p pm
Table 2
CODES
Q45
Q40
Q35
Q30
Q25
Q20
Q15
Q10
Q115
TRIMMED L in(mm)
0.45 (11.43)
0.40 (10.16)
0.35 (8.89)
0.30 (7.62)
0.25 (6.35)
0.20 (5.08)
0.15 (3.81)
0.10 (2.54)
0.115 (2.92)
NOTE: Use appropriat e code numbers for
other trimmed lengths not liste d.
(e.g. Q14 for 0.14 inch (3.55 mm))
Fund. BT>24MHz
3rd OT>66MHz
Insulator Tab
Vinyl Sleeve
T rimmed lea ds
See Ta ble 2
Metal jacket
NOTE:
*:Fr equency Stability ± 100
ppm max at -10 to +60C only
for BT cut.
** : -10 to +60C only.
*** : Quality factor must be
ac companied by a k value
LLC
5101 Hidden Creek Lane Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sale please visit:
www.abracon.com
REVISED: 01.05.2017
ABRACON IS
ISO9001-2008
CERTIFIED
HC49/U CRYSTAL
AB
OUTLINE DRAWING:
Insulator Tab
For Option I
Pb
RoHS/RoHS II Compliant
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
Vinyl Sleeve
For Option V
Dimensions: inch (mm)
LLC
5101 Hidden Creek Lane Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sale please visit:
www.abracon.com
REVISED: 01.05.2017
ABRACON IS
ISO9001-2008
CERTIFIED
HC49/U CRYSTAL
AB
OUTLINE DIMENSION CONTD...
Metal Jacket Formed Leads
For Option MJ
Pb
RoHS/RoHS II Compliant
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
T 1,000 pcs/reel
Dimensions: mm
TAPE & REEL:
T: 1,000 pcs/reel
Tape and reel packaging applies only to MJ (metal jacket) option
E
1.75±0.10
E2
22.25 MIN.
F
11.5±0.10
P2
2.00±0.10
ØD0
1.50±0.10
P0
4.00±0.10
W
24.00±0.30
Dimensions: mm
ATTENTION:
Abracon products are COTS – Commercial-Off-The-Shelf products; suitable for Commercial, Industrial and, where designated, Automotive Applications.
Abracon’s products are not specifically designed for Military, Aviation, Aerospace, Life-dependant Medical applications or any application requiring high reliability where
component failure could result in loss of life and/or property. For applications requiring high reliability and/or presenting an extreme operating environment, written consent and
authorization from Abracon is required. Please contact Abracon for more information.
This solution designs a valve intelligent controller installed on the electric valve system. The electric valve electrical control part consists of a motor control mechanism, a stroke control mechanis...
The internal instruction cycle of DSP is high, and the main frequency of external crystal oscillator is not enough, so most DSP chips have PLL. But each series is different.1) TMS320C2000 series:TMS32...
How to write pictures and table data into Word in WinCE? Is there any class or plug-in that can achieve this function? It seems to be a very commonly used function....
I want to implement D3DM display in Windows CE, but I don't know how to use unmanaged programs to implement 3D images exported from .x files. Ma Ning gave a lecture, but the lecture was not very clear...
I use MSVC1.52 to compile loadcepc.mak. I am currently compiling it on XP. What is going on? What should I set? Or is the system wrong? Should I change the system? Error message: Invoking external bui...
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
In public places such as schools, government agencies, factories and mines, as well as public corridors in residential areas, the phenomenon of long-burning lights is very common, which causes a h...[Details]
My colleague and I spent the day chatting in the hotel bar. We had met with several customers. We were both wondering how come these engineers we were meeting knew almost nothing about analog techn...[Details]
In the analysis of electronic circuits, static analysis (also known as DC analysis) is the basis of circuit analysis. However, it is well known that electronic components are nonlinear, so the anal...[Details]
RS-422 and RS-485 are both serial data interface standards, which were developed and published by the Electronic Industries Association (EIA). RS-422 defines a balanced communication interface with a ...[Details]
Printed circuit boards ( PCBs
)
are used in most electrical products
. If a PCB has low
insulation resistance
(IR), the performance of the circuits on the PCB will be greatly reduced...[Details]
Describe how to meet the challenges of complexity with a modern wiring design toolset. Option codes and expressions can simulate the variables of an automotive project. A full-featured tool suite c...[Details]
Since the late 1990s, with the demand for higher system efficiency and lower power consumption, the technological update of telecommunications and data communication equipment has promoted the deve...[Details]
With the rapid development of cities and the improvement of citizens' living standards, the number of various vehicles in cities is growing, and the demand for parking spaces in major commercial an...[Details]
Electric bicycles have long been a means of transportation for lower-income groups due to their affordability. The largest concentrated expense in the use of electric vehicles is the cost of replac...[Details]
Rated capacity refers to the maximum output power of the UPS (the product of voltage V and current A).
Usually, the UPS power supplies sold on the market are marked with "W" (watt) for smaller...[Details]
This article introduces a high-reliability, high-power automatic water supply device made with 89C2051 single-chip microcomputer, which has phase loss detection, over-temperature detection, over-cu...[Details]
At present, more than 40 fieldbuses have been developed in the world, among which CAN bus is suitable for application in automobile inspection lines because of its unique features such as strong re...[Details]
1. Introduction
With the rapid development of computer technology, communication technology, and integrated circuit technology, the large-scale application of field control instruments and equ...[Details]
A stepper motor is a motor that converts electrical pulse signals into linear or angular displacements. However, the control of stepper motors is usually developed in assembly language or C languag...[Details]