EEWORLDEEWORLDEEWORLD

Part Number

Search

A15115C0GL5

Description
Axial Leaded Multilayer Ceramic Capacitors for General Purpose Class 1, Class 2 and Class 3, 50 VDC, 100 VDC, 200 VDC, 500 VDC
File Size113KB,9 Pages
ManufacturerVishay
Websitehttp://www.vishay.com
Download Datasheet View All

A15115C0GL5 Overview

Axial Leaded Multilayer Ceramic Capacitors for General Purpose Class 1, Class 2 and Class 3, 50 VDC, 100 VDC, 200 VDC, 500 VDC

A Series
www.vishay.com
Vishay BCcomponents
Axial Leaded Multilayer Ceramic Capacitors for General Purpose
Class 1, Class 2 and Class 3, 50 V
DC
, 100 V
DC
, 200 V
DC
, 500 V
DC
FEATURES
High capacitance with small size
High reliability
Axial mounting style
Material categorization:
For definitions of compliance please see
www.vishay.com/doc?99912
APPLICATIONS
• Temperature compensation
• Coupling and decoupling
QUICK REFERENCE DATA
DESCRIPTION
Ceramic Class
Ceramic Dielectric
Voltage (V
DC
)
Min. Capacitance (pF)
Max. Capacitance (pF)
Mounting
50
10
10 000
100
10
5600
1
C0G
200
33
2200
500
33
1000
50
100
1 000 000
Axial
100
100
220 000
VALUE
2
X7R
200
100
47 000
500
100
33 000
50
10 000
1 000 000
3
Y5V
100
10 000
220 000
MARKING
Marking indicates capacitance value and tolerance in
accordance with “EIA 198” and voltage marks.
CAPACITANCE RANGE
10 pF to 1 μF
TOLERANCE ON CAPACITANCE
OPERATING TEMPERATURE RANGE
C0G, X7R: - 55 °C to + 125 °C
Y5V: - 30 °C to + 85 °C
± 5 %, ± 10 %, ± 20 %, + 80 %/- 20 %
RATED VOLTAGE
50 V
DC
, 100 V
DC
, 200 V
DC
, 500 V
DC
TEMPERATURE CHARACTERISTICS
Class 1: C0G
Class 2: X7R
Class 3: Y5V
TEST VOLTAGE
• 50 V
DC
and 100 V
DC
: 250 % of rated voltage
• 200 V
DC
: 150 % of rated voltage + 100 V
DC
• 500 V
DC
: 130 % of rated voltage + 100 V
DC
SECTIONAL SPECIFICATIONS
Climatic category (acc. to EN 60058-1)
Class 1 and 2: 55/125/21
Class 3: 30/85/21
INSULATION RESISTANCE AT 500 V
DC
• 50 V
DC
and 100 V
DC
: 100 G or 1000
F
whichever is less
at rated voltage within 2 min of charging
• 200 V
DC
and 500 V
DC
: 10 G or 100
F
whichever is less
at rated voltage within 2 min of charging
APPROVALS
EIA 198
IEC 60384-9
DISSIPATION FACTOR
Class 1:
0.1 % max. when C
30 pF
(at 1 MHz; 1 V where C
1000 pF,
and at 1 kHz; 1 V where C > 1000 pF)
For C < 30 pF: DF = 100/(400 + 20 x C)
DF = Disspation factor in %;
C = Capacitance value in pF
2.5 % max. (at 1 kHz; 1 V)
5 % max. (at 1 kHz; 1 V)
DESIGN
• The capacitors consist of a general purpose MLCC
• The lead wires are 0.5 mm and are made of 100 % tinned
copper clad steel wire
• Coating is made of yellow colored flame retardant epoxy
resin in accordance with UL 94 V-0
Class 2:
Class 3:
Revision: 20-Aug-13
Document Number: 45164
1
For technical questions, contact:
cmll@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
The legendary LabVIEW graduation thesis
I will provide two first. I really can't download them anymore. If you want to download them, you can go and have a look. Remember to give me a thumbs up!! Thank you! Please give me a thumbs up just f...
chaoren Test/Measurement
If there is no reference ground at all, do you think it is still possible to control the impedance?
Author: Huang Gang, member of YiBo Technology Expressway Mr.As an SI engineer, PCB design engineer, or even a hardware engineer and test engineer, calculating transmission line impedance is definitely...
yvonneGan PCB Design
Photo report of the 7th Beijing International Pure Electric and Hybrid Vehicle Exhibition
On the morning of July 3rd, when the sun was shining brightly, Aniu went to Jing'anzhuang National Exhibition to attend the International Pure Electric and Hybrid Vehicle Exhibition. AVNET exhibited I...
jameswangsynnex Energy Infrastructure?
Weekly highlights: 2017.8.28-2017.9.3
[size=4]Hi, good morning, everyone~~ I got up early today~~~:loveliness: I'll quickly send you some wonderful stuff~[/size] [size=4][color=#ff0000][b]Recommended wonderful posts:[/b][/color][/size] [s...
okhxyyo Energy Infrastructure?
How to solve the problem of "The breakpoint will not be hit currently. The specified module has not been loaded" when debugging in vs2005+wince5.0 simulator?
How to solve the problem "The breakpoint will not be hit. The specified module has not been loaded" when debugging in vs2005+wince5.0 simulator? A simple form+button program, when the device is wince5...
cattyzeal Embedded System
Power engineers are most afraid of EMC, analyze it like this! (Reposted)
[size=4] As the speed of switching power supplies is getting faster and faster, the power is getting higher and higher, and the density is getting larger and larger, interference problems will inevita...
qwqwqw2088 Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2858  1862  1190  1107  81  58  38  24  23  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号