*Contact factory for SRC9000 Space Level SCD details.
For RoHS compliant products,
please select correct termination style.
TECHNICAL SPECIFICATIONS
Technical Data:
Capacitance Range:
Capacitance Tolerance:
Rated Voltage (V
R
)
Category Voltage (V
C
)
Surge Voltage (V
S
)
Surge Voltage (V
S
)
Temperature Range:
Unless otherwise specified, all technical data relate to an ambient temperature of 25°C
0.10 μF to 100 μF
±5%; ±10%; ±20%
4
6
10
15
20
25
35
50
2.7
4
6.7
10
13.3
16.7
23.3
33.3
5.3
8
13.3
20
26.7
33.3
46.7
66.7
3.5
5.3
8.7
13.3
17.8
22.2
31.1
44.5
-55°C to +125°C
≤ 85°C:
≤125°C:
≤ 85°C:
≤125°C:
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or available
online at www.kyocera-avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
032322
9
–
high reliability tantalum capacitors
–
TAZ SERIES
CWR09 - MIL-PRF-55365/4 Established Reliability,
COTS-Plus & Space Level
Parametric Specifications by Rating per MIL-PRF-55365/4
ESR
DCL max
DF Max
DC Rated
@
+(85/125)
Voltage
+25ºC
+85ºC
+125ºC
+25ºC
100kHz
ºC
V
Ohms
@ +85ºC @ +25ºC
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
10
10
10
10
10
10
10
10
10
10
10
15
15
15
15
15
15
15
15
20
20
20
20
20
20
20
20
20
45
12
8
8
5.5
4
3.5
2.2
1.1
0.9
8
8
5.5
4.5
3.5
2.2
1.1
0.9
50
50
10
10
8
5.5
4.5
3.5
2.5
1.1
0.9
12
8
5.5
5
4
2.5
1.1
0.9
14
10
12
6
5
4
2.4
1.1
0.9
(μA)
1
1
1
1
1
1
1
2
3
4
1
1
1
1
1
2
3
4
1
1
1
1
1
1
1
1
2
3
5
1
1
1
1
1
2
4
5
1
1
1
1
1
1
2
3
4
(μA)
10
10
10
10
10
10
10
20
30
40
10
10
10
10
10
20
30
40
10
10
10
10
10
10
10
10
20
30
50
10
10
10
10
10
20
40
50
10
10
10
10
10
10
20
30
40
(μA)
12
12
12
12
12
12
12
24
36
48
12
12
12
12
12
24
36
48
12
12
12
12
12
12
12
12
24
36
60
12
12
12
12
12
24
48
60
12
12
12
12
12
12
24
36
48
(%)
6
6
6
6
6
8
8
8
10
10
6
6
6
6
8
8
10
10
6
6
6
6
6
6
6
6
8
10
10
6
6
6
6
6
6
6
8
8
6
6
6
6
6
6
6
6
(%)
8
8
8
8
8
8
10
10
12
12
8
8
8
8
10
10
12
12
8
8
8
8
8
8
8
8
8
12
12
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Typical RMS Ripple Data by Rating
-55ºC
(%)
8
8
8
8
8
10
12
12
12
12
8
8
8
8
12
12
12
12
8
8
8
8
8
8
8
8
10
12
12
8
8
8
8
8
8
8
10
10
8
8
8
8
8
8
8
8
Power
Dissipation
W
0.030
0.030
0.050
0.070
0.075
0.080
0.090
0.100
0.125
0.150
0.050
0.070
0.075
0.080
0.090
0.100
0.125
0.150
0.030
0.030
0.030
0.050
0.070
0.075
0.080
0.090
0.100
0.125
0.150
0.050
0.070
0.075
0.080
0.090
0.100
0.125
0.150
0.050
0.070
0.070
0.075
0.080
0.090
0.100
0.125
0.150
25ºC
Ripple
A
(100kHz)
0.03
0.05
0.08
0.09
0.12
0.14
0.16
0.21
0.34
0.41
0.08
0.09
0.12
0.13
0.16
0.21
0.34
0.41
0.02
0.02
0.05
0.07
0.09
0.12
0.13
0.16
0.20
0.34
0.41
0.06
0.09
0.12
0.13
0.15
0.20
0.34
0.41
0.06
0.08
0.08
0.11
0.13
0.15
0.20
0.34
0.41
85ºC
Ripple
125ºC
Ripple
25ºC
Ripple
85ºC
Ripple
125ºC
Ripple
RATING & PART NUMBER REFERENCE
CWR09 P/N
MIL & COTS-Plus P/N
TAZ R 334 * 004 C
#
@
0 ^ ++
TAZ R 225 * 004 C
#
@
0 ^ ++
TAZ A 225 * 004 C
#
@
0 ^ ++
TAZ B 475 * 004 C
#
@
0 ^ ++
TAZ C 685 * 004 C
#
@
0 ^ ++
TAZ D 106 * 004 C
#
@
0 ^ ++
TAZ E 156 * 004 C
#
@
0 ^ ++
TAZ F 336 * 004 C
#
@
0 ^ ++
TAZ G 686 * 004 C
#
@
0 ^ ++
TAZ H 107 * 004 C
#
@
0 ^ ++
TAZ A 155 * 006 C
#
@
0 ^ ++
TAZ B 335 * 006 C
#
@
0 ^ ++
TAZ C 475 * 006 C
#
@
0 ^ ++
TAZ D 685 * 006 C
#
@
0 ^ ++
TAZ E 106 * 006 C
#
@
0 ^ ++
TAZ F 226 * 006 C
#
@
0 ^ ++
TAZ G 476 * 006 C
#
@
0 ^ ++
TAZ H 686 * 006 C
#
@
0 ^ ++
TAZ R 334 * 010 C
#
@
0 ^ ++
TAZ R 474 * 010 C
#
@
0 ^ ++
TAZ R 105 * 010 C
#
@
0 ^ ++
TAZ A 105 * 010 C
#
@
0 ^ ++
TAZ B 225 * 010 C
#
@
0 ^ ++
TAZ C 335 * 010 C
#
@
0 ^ ++
TAZ D 475 * 010 C
#
@
0 ^ ++
TAZ E 685 * 010 C
#
@
0 ^ ++
TAZ F 156 * 010 C
#
@
0 ^ ++
TAZ G 336 * 010 C
#
@
0 ^ ++
TAZ H 476 * 010 C
#
@
0 ^ ++
TAZ A 684 * 015 C
#
@
0 ^ ++
TAZ B 155 * 015 C
#
@
0 ^ ++
TAZ C 225 * 015 C
#
@
0 ^ ++
TAZ D 335 * 015 C
#
@
0 ^ ++
TAZ E 475 * 015 C
#
@
0 ^ ++
TAZ F 106 * 015 C
#
@
0 ^ ++
TAZ G 226 * 015 C
#
@
0 ^ ++
TAZ H 336 * 015 C
#
@
0 ^ ++
TAZ A 474 * 020 C
#
@
0 ^ ++
TAZ B 684 * 020 C
#
@
0 ^ ++
TAZ B 105 * 020 C
#
@
0 ^ ++
TAZ C 155 * 020 C
#
@
0 ^ ++
TAZ D 225 * 020 C
#
@
0 ^ ++
TAZ E 335 * 020 C
#
@
0 ^ ++
TAZ F 685 * 020 C
#
@
0 ^ ++
TAZ G 156 * 020 C
#
@
0 ^ ++
TAZ H 226 * 020 C
#
@
0 ^ ++
SRC9000 P/N
Case
R
R
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
R
R
R
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
A
B
B
C
D
E
F
G
H
Cap
@ 120Hz
μF
@ 25ºC
0.33
2.2
2.2
4.7
6.8
10
15
33
68
100
1.5
3.3
4.7
6.8
10
22
47
68
0.33
0.47
1
1
2.2
3.3
4.7
6.8
15
33
47
0.68
1.5
2.2
3.3
4.7
10
22
33
0.47
0.68
1
1.5
2.2
3.3
6.8
15
22
A
A
V
V
V
(100kHz) (100kHz) (100kHz) (100kHz) (100kHz)
0.02
0.05
0.07
0.08
0.11
0.13
0.14
0.19
0.30
0.37
0.07
0.08
0.11
0.12
0.14
0.19
0.30
0.37
0.02
0.02
0.05
0.06
0.08
0.11
0.12
0.14
0.18
0.30
0.37
0.06
0.08
0.11
0.11
0.14
0.18
0.30
0.37
0.05
0.08
0.07
0.10
0.11
0.14
0.18
0.30
0.37
0.01
0.02
0.03
0.04
0.05
0.06
0.06
0.09
0.13
0.16
0.03
0.04
0.05
0.05
0.06
0.09
0.13
0.16
0.01
0.01
0.02
0.03
0.04
0.05
0.05
0.06
0.08
0.13
0.16
0.03
0.04
0.05
0.05
0.06
0.08
0.13
0.16
0.02
0.03
0.03
0.04
0.05
0.06
0.08
0.13
0.16
1.16
0.60
0.63
0.75
0.64
0.57
0.56
0.47
0.37
0.37
0.63
0.75
0.64
0.60
0.56
0.47
0.37
0.37
1.22
1.22
0.55
0.71
0.75
0.64
0.60
0.56
0.50
0.37
0.37
0.77
0.75
0.64
0.63
0.60
0.50
0.37
0.37
0.84
0.84
0.92
0.67
0.63
0.60
0.49
0.37
0.37
1.05
0.54
0.57
0.67
0.58
0.51
0.51
0.42
0.33
0.33
0.57
0.67
0.58
0.54
0.51
0.42
0.33
0.33
1.10
1.10
0.49
0.64
0.67
0.58
0.54
0.51
0.45
0.33
0.33
0.70
0.67
0.58
0.57
0.54
0.45
0.33
0.33
0.75
0.75
0.82
0.60
0.57
0.54
0.44
0.33
0.33
0.46
0.24
0.25
0.30
0.26
0.23
0.22
0.19
0.15
0.15
0.25
0.30
0.26
0.24
0.22
0.19
0.15
0.15
0.49
0.49
0.22
0.28
0.30
0.26
0.24
0.22
0.20
0.15
0.15
0.31
0.30
0.26
0.25
0.24
0.20
0.15
0.15
0.33
0.33
0.37
0.27
0.25
0.24
0.20
0.15
0.15
CWR09C^225*@+
CWR09C^475*@+
CWR09C^685*@+
CWR09C^106*@+
CWR09C^156*@+
CWR09C^336*@+
CWR09C^686*@+
CWR09C^107*@+
CWR09D^155*@+
CWR09D^335*@+
CWR09D^475*@+
CWR09D^685*@+
CWR09D^106*@+
CWR09D^226*@+
CWR09D^476*@+
CWR09D^686*@+
TAZ A 225 * 004 C
L
@
9 ^ ++
TAZ B 475 * 004 C
L
@
9 ^ ++
TAZ C 685 * 004 C
L
@
9 ^ ++
TAZ D 106 * 004 C
L
@
9 ^ ++
TAZ E 156 * 004 C
L
@
9 ^ ++
TAZ F 336 * 004 C
L
@
9 ^ ++
TAZ G 686 * 004 C
L
@
9 ^ ++
TAZ H 107 * 004 C
L
@
9 ^ ++
TAZ A 155 * 006 C
L
@
9 ^ ++
TAZ B 335 * 006 C
L
@
9 ^ ++
TAZ C 475 * 006 C
L
@
9 ^ ++
TAZ D 685 * 006 C
L
@
9 ^ ++
TAZ E 106 * 006 C
L
@
9 ^ ++
TAZ F 226 * 006 C
L
@
9 ^ ++
TAZ G 476 * 006 C
L
@
9 ^ ++
TAZ H 686 * 006 C
L
@
9 ^ ++
CWR09F^105*@+
CWR09F^225*@+
CWR09F^335*@+
CWR09F^475*@+
CWR09F^685*@+
CWR09F^156*@+
CWR09F^336*@+
CWR09F^476*@+
CWR09H^684*@+
CWR09H^155*@+
CWR09H^225*@+
CWR09H^335*@+
CWR09H^475*@+
CWR09H^106*@+
CWR09H^226*@+
CWR09H^336*@+
CWR09J^474*@+
CWR09J^684*@+
CWR09J^105*@+
CWR09J^155*@+
CWR09J^225*@+
CWR09J^335*@+
CWR09J^685*@+
CWR09J^156*@+
CWR09J^226*@+
TAZ A 105 * 010 C
L
@
9 ^ ++
TAZ B 225 * 010 C
L
@
9 ^ ++
TAZ C 335 * 010 C
L
@
9 ^ ++
TAZ D 475 * 010 C
L
@
9 ^ ++
TAZ E 685 * 010 C
L
@
9 ^ ++
TAZ F 156 * 010 C
L
@
9 ^ ++
TAZ G 336 * 010 C
L
@
9 ^ ++
TAZ H 476 * 010 C
L
@
9 ^ ++
TAZ A 684 * 015 C
L
@
9 ^ ++
TAZ B 155 * 015 C
L
@
9 ^ ++
TAZ C 225 * 015 C
L
@
9 ^ ++
TAZ D 335 * 015 C
L
@
9 ^ ++
TAZ E 475 * 015 C
L
@
9 ^ ++
TAZ F 106 * 015 C
L
@
9 ^ ++
TAZ G 226 * 015 C
L
@
9 ^ ++
TAZ H 336 * 015 C
L
@
9 ^ ++
TAZ A 474 * 020 C
L
@
9 ^ ++
TAZ B 684 * 020 C
L
@
9 ^ ++
TAZ B 105 * 020 C
L
@
9 ^ ++
TAZ C 155 * 020 C
L
@
9 ^ ++
TAZ D 225 * 020 C
L
@
9 ^ ++
TAZ E 335 * 020 C
L
@
9 ^ ++
TAZ F 685 * 020 C
L
@
9 ^ ++
TAZ G 156 * 020 C
L
@
9 ^ ++
TAZ H 226 * 020 C
L
@
9 ^ ++
All technical data relates to an ambient temperature of +25°C. Capacitance and DF are measured at 120Hz, 0.5V RMS with a maximum DC bias of 2.2 volts. DCL is measured at rated voltage after 5 minutes.
NOTE: KYOCERA AVX reserves the right to supply a higher voltage rating or tighter tolerance part in the same case size, to the same reliability standards.
10
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or available
online at www.kyocera-avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
062620
–
high reliability tantalum capacitors
–
TAZ SERIES
CWR09 - MIL-PRF-55365/4 Established Reliability,
COTS-Plus & Space Level
RATING & PART NUMBER REFERENCE
CWR09 P/N
CWR09K^334*@+
CWR09K^684*@+
CWR09K^105*@+
CWR09K^155*@+
CWR09K^225*@+
CWR09K^475*@+
CWR09K^685*@+
CWR09K^106*@+
CWR09K^156*@+
CWR09M^224*@+
CWR09M^474*@+
CWR09M^684*@+
CWR09M^105*@+
CWR09M^155*@+
CWR09M^335*@+
CWR09M^475*@+
CWR09M^685*@+
CWR09N^104*@+
CWR09N^154*@+
CWR09N^224*@+
CWR09N^334*@+
CWR09N^474*@+
CWR09N^684*@+
CWR09N^105*@+
CWR09N^155*@+
CWR09N^225*@+
CWR09N^335*@+
CWR09N^475*@+
MIL & COTS-Plus P/N
TAZ A 334 * 025 C
#
@
0 ^ ++
TAZ B 684 * 025 C
#
@
0 ^ ++
TAZ C 105 * 025 C
#
@
0 ^ ++
TAZ D 155 * 025 C
#
@
0 ^ ++
TAZ E 225 * 025 C
#
@
0 ^ ++
TAZ F 475 * 025 C
#
@
0 ^ ++
TAZ G 685 * 025 C
#
@
0 ^ ++
TAZ G 106 * 025 C
#
@
0 ^ ++
TAZ H 156 * 025 C
#
@
0 ^ ++
TAZ A 224 * 035 C #
@
0 ^ ++
TAZ B 474 * 035 C #
@
0 ^ ++
TAZ C 684 * 035 C #
@
0 ^ ++
TAZ D 105 * 035 C #
@
0 ^ ++
TAZ E 155 * 035 C #
@
0 ^ ++
TAZ F 335 * 035 C #
@
0 ^ ++
TAZ G 475 * 035 C #
@
0 ^ ++
TAZ H 685 * 035 C #
@
0 ^ ++
TAZ A 104 * 050 C #
@
0 ^ ++
TAZ A 154 * 050 C #
@
0 ^ ++
TAZ B 224 * 050 C #
@
0 ^ ++
TAZ B 334 * 050 C #
@
0 ^ ++
TAZ C 474 * 050 C #
@
0 ^ ++
TAZ D 684 * 050 C #
@
0 ^ ++
TAZ E 105 * 050 C #
@
0 ^ ++
TAZ F 155 * 050 C #
@
0 ^ ++
TAZ F 225 * 050 C #
@
0 ^ ++
TAZ G 335 * 050 C #
@
0 ^ ++
TAZ H 475 * 050 C #
@
0 ^ ++
SRC9000 P/N
TAZ A 334 * 025 C
L
@
9 ^ ++
TAZ B 684 * 025 C
L
@
9 ^ ++
TAZ C 105 * 025 C
L
@
9 ^ ++
TAZ D 155 * 025 C
L
@
9 ^ ++
TAZ E 225 * 025 C
L
@
9 ^ ++
TAZ F 475 * 025 C
L
@
9 ^ ++
TAZ G 685 * 025 C
L
@
9 ^ ++
TAZ G 106 * 025 C
L
@
9 ^ ++
TAZ H 156 * 025 C
L
@
9 ^ ++
TAZ A 224 * 035 C L
@
9 ^ ++
TAZ B 474 * 035 C L
@
9 ^ ++
TAZ C 684 * 035 C L
@
9 ^ ++
TAZ D 105 * 035 C L
@
9 ^ ++
TAZ E 155 * 035 C L
@
9 ^ ++
TAZ F 335 * 035 C L
@
9 ^ ++
TAZ G 475 * 035 C L
@
9 ^ ++
TAZ H 685 * 035 C L
@
9 ^ ++
TAZ A 104 * 050 C L
@
9 ^ ++
TAZ A 154 * 050 C L
@
9 ^ ++
TAZ B 224 * 050 C L
@
9 ^ ++
TAZ B 334 * 050 C L
@
9 ^ ++
TAZ C 474 * 050 C L
@
9 ^ ++
TAZ D 684 * 050 C L
@
9 ^ ++
TAZ E 105 * 050 C L
@
9 ^ ++
TAZ F 155 * 050 C L
@
9 ^ ++
TAZ F 225 * 050 C L
@
9 ^ ++
TAZ G 335 * 050 C L
@
9 ^ ++
TAZ H 475 * 050 C L
@
9 ^ ++
Case
A
B
C
D
E
F
G
G
H
A
B
C
D
E
F
G
H
A
A
B
B
C
D
E
F
F
G
H
Cap
@ 120Hz
μF
@ 25ºC
0.33
0.68
1
1.5
2.2
4.7
6.8
10
15
0.22
0.47
0.68
1
1.5
3.3
4.7
6.8
0.1
0.15
0.22
0.33
0.47
0.68
1
1.5
2.2
3.3
4.7
Parametric Specifications by Rating per MIL-PRF-55365/4
ESR
DCL max
DF Max
DC Rated
@
+(85/125)
Voltage
+25ºC
+85ºC
+125ºC
+25ºC
100kHz
ºC
V
Ohms
@ +85ºC @ +25ºC
25
25
25
25
25
25
25
25
25
35
35
35
35
35
35
35
35
50
50
50
50
50
50
50
50
50
50
50
15
7.5
6.5
6.5
3.5
2.5
1.2
1.4
1
18
10
8
6.5
4.5
2.5
1.5
1.3
22
17
14
12
8
7
6
4
2.5
2
1.5
(μA)
1
1
1
1
1
2
2
3
4
1
1
1
1
1
1
2
3
1
1
1
1
1
1
1
1
2
2
3
(μA)
10
10
10
10
10
20
20
30
40
10
10
10
10
10
10
20
30
10
10
10
10
10
10
10
10
20
20
30
(μA)
12
12
12
12
12
24
24
36
48
12
12
12
12
12
12
24
36
12
12
12
12
12
12
12
12
24
24
36
(%)
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
(%)
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Typical RMS Ripple Data by Rating
-55ºC
(%)
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Power
Dissipation
W
0.050
0.070
0.075
0.080
0.090
0.100
0.125
0.125
0.150
0.050
0.070
0.075
0.080
0.090
0.100
0.125
0.150
0.050
0.050
0.070
0.070
0.075
0.080
0.090
0.100
0.100
0.125
0.150
25ºC
Ripple
A
(100kHz)
0.06
0.10
0.11
0.11
0.16
0.20
0.32
0.30
0.39
0.05
0.08
0.10
0.11
0.14
0.20
0.29
0.34
0.05
0.05
0.07
0.08
0.10
0.11
0.12
0.16
0.20
0.25
0.32
85ºC
Ripple
125ºC
Ripple
25ºC
Ripple
85ºC
Ripple
125ºC
Ripple
A
A
V
V
V
(100kHz) (100kHz) (100kHz) (100kHz) (100kHz)
0.05
0.09
0.10
0.10
0.14
0.18
0.29
0.27
0.35
0.05
0.08
0.09
0.10
0.13
0.18
0.26
0.31
0.04
0.05
0.06
0.07
0.09
0.10
0.11
0.14
0.18
0.23
0.28
0.02
0.04
0.04
0.04
0.06
0.08
0.13
0.12
0.15
0.02
0.03
0.04
0.04
0.06
0.08
0.12
0.14
0.02
0.02
0.03
0.03
0.04
0.04
0.05
0.06
0.08
0.10
0.13
0.87
0.72
0.70
0.72
0.56
0.50
0.39
0.42
0.39
0.95
0.84
0.77
0.72
0.64
0.50
0.43
0.44
1.05
0.92
0.99
0.92
0.77
0.75
0.73
0.63
0.50
0.50
0.47
0.78
0.65
0.63
0.65
0.51
0.45
0.35
0.38
0.35
0.85
0.75
0.70
0.65
0.57
0.45
0.39
0.40
0.94
0.83
0.89
0.82
0.70
0.67
0.66
0.57
0.45
0.45
0.43
0.35
0.29
0.28
0.29
0.22
0.20
0.15
0.17
0.15
0.38
0.33
0.31
0.29
0.25
0.20
0.17
0.18
0.42
0.37
0.40
0.37
0.31
0.30
0.29
0.25
0.20
0.20
0.19
All technical data relates to an ambient temperature of +25°C. Capacitance and DF are measured at 120Hz, 0.5V RMS with a maximum DC bias of 2.2 volts. DCL is measured at rated voltage after 5 minutes.
NOTE: KYOCERA AVX reserves the right to supply a higher voltage rating or tighter tolerance part in the same case size, to the same reliability standards.
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or available
online at www.kyocera-avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
062620
11
–
high reliability tantalum capacitors
–
TAZ SERIES
CWR19 - MIL-PRF-55365/11 Established Reliability,
COTS-Plus & Space Level
An extended range of capacitor ratings beyond
CWR09 that is fully qualified to MIL-PRF-55365/11,
this series represents the most flexible of surface
mount form factors, offering nine case sizes (the
original A through H of CWR09) and adds the new
X case size.
The molded body / compliant termination
construction ensures no TCE mismatch with any
substrate. This construction is compatible with
a wide range of SMT board assembly processes
including convection reflow solder, conductive epoxy
or compression bonding techniques. The parts also
carry full polarity and capacitance / voltage marking.
The four smaller cases are characterized by their low
profile construction, with the A case being the world’s
smallest molded military tantalum chip.
The series is qualified to MIL-PRF-55365 Weibull
“B”, “C”, “D” and “T” levels, with all surge options
(“A”, “B” & “C”) available.
For Space Level applications, SRC 9000
qualification is recommended (see ratings table
for part number availability).
There are four termination finishes available:
solder plated, fused solder plated, hot solder
dipped and gold plated (these are “H”, “K”, “C” and
“B” termination, respectively, per MIL-PRF-55365).
In addition, the molding compound has been
selected to meet the requirements of UL94V-0
(Flame Retardancy) and outgassing requirements
of ASTM E-595.
For moisture sensitivity levels please refer to the High
Reliability Tantalum MSL section located in the back
of the High Reliability Tantalum Catalog.
CASE DIMENSIONS:
Case
Code
Length (L)
±0.38
(0.015)
Width (W)
±0.38
(0.015)
Height (H)
±0.38
(0.015)
Term. Width
(W
1
)
1.27±0.13
(0.050±0.005)
1.27±0.13
(0.050±0.005)
1.27±0.13
(0.050±0.005)
2.41+0.13/-0.25
(0.095+0.005/-0.010)
2.41+0.13/-0.25
(0.095+0.005/-0.010)
3.30±0.13
(0.130±0.005)
2.67±0.13
(0.105±0.005)
3.68+0.13/-0.51
(0.145+0.005/-0.020)
3.05±0.13
(0.120±0.005)
millimeters (inches)
Term. Length (A)
+0.25/-0.13
(+0.010/-0.005)
0.76 (0.030)
0.76 (0.030)
0.76 (0.030)
0.76 (0.030)
0.76 (0.030)
0.76 (0.030)
1.27 (0.050)
1.27 (0.050)
1.19 (0.047)
S min
0.38 (0.015)
1.65 (0.065)
2.92 (0.115)
1.65 (0.065)
2.92 (0.115)
3.43 (0.135)
3.56 (0.140)
4.06 (0.160)
3.67 (0.144)
Typical
Weight (g)
0.016
0.025
0.035
0.045
0.065
0.125
0.205
0.335
0.420
MARKING
(White marking on black body)
Polarity Stripe (+)
Capacitance Code
Rated Voltage
A
B
C
D
E
F
G
H
X
2.54 (0.100) 1.27 (0.050) 1.27 (0.050)
3.81 (0.150) 1.27 (0.050) 1.27 (0.050)
5.08 (0.200) 1.27 (0.050) 1.27 (0.050)
3.81 (0.150) 2.54 (0.100) 1.27 (0.050)
5.08 (0.200) 2.54 (0.100) 1.27 (0.050)
5.59 (0.220) 3.43 (0.135) 1.78 (0.070)
6.73 (0.265) 2.79 (0.110)
7.24 (0.285) 3.81 (0.150)
6.93 (0.273) 5.41 (0.213)
2.79 (0.110)
2.79 (0.110)
2.74 (0.108)
CWR19-MIL-PRF 55365/11
CAPACITANCE AND RATED VOLTAGE, V
R
(VOLTAGE CODE) RANGE (LETTER DENOTES CASE SIZE)
Capacitance
µF
0.33
0.47
0.68
1.0
1.5
2.2
3.3
4.7
6.8
10
15
22
33
47
68
100
150
220
330
Code
334
474
684
105
155
225
335
475
685
106
156
226
336
476
686
107
157
227
337
4V (C)
6V (D)
Rated Voltage DC (V
R
) at 85ºC
10V (F)
15V (H)
20V (J)
25V (K)
A
B
D
E
F
G
G/H
H/X
G
H
X
35V (M)
A
A
A
A
B
B
B/D
D/E
E
E
F
G
H
H
A
A
B
B
B/D/E
D/E
E
F
F/G
G
G
H
H
A
A
B/C
B/C/D
B/C/D/E
D/E
E
F
F/G
G
G/H
H/X
H
A
A
A
B
B/C/D
D/E
D/E
E/F
F
F/G
G/H
G/H
H
A
A
B
B
D
E
E
E/F
F
G
H
H/X
12
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or available
online at www.kyocera-avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
Item Description Product Information SmartAX MT800 MAC address 00:73:06:14:2F:68 Software version V100R001B016 Firmware version Y.1.28.210 / 2.8.051115r Release date May 9, 2006 Batch number SCCAP1 AD...
I think some of you have used CC2500 wireless chip? I am using it recently, but I have a lot of questions about its configuration. I hope experts can give me some advice and help me get out of the sea...
[font=Times New Roman] [/font] [font=宋体][size=10.5pt]The electrostatic induction perimeter alarm detector is essentially different from perimeter alarm systems such as microwave radiation, infrared ra...
I tried to make a board with a chip packaged Macrochip microcomputer, but I can't burn the program using the MAX232 serial port. After powering on, a square wave appears on the chip's 27 pin (ALE), an...
Designers use PSpice primarily to simulate analog circuits. However, it can also be used to simulate digital filters. The main components in a digital filter are delay elements, adders, and multipl...[Details]
1 Introduction
The integration of sensor technology and RFID has just started. As one of the world's major manufacturing and consumer countries, China should seize this opportunit...[Details]
The role of digital-to-analog converters
Real-world analog signals, such as temperature, pressure, sound, or images, are constantly being converted into digital form that is easier to store, p...[Details]
Keeping the heart environment compact and warm is beneficial in most cases, but it’s another story for electronic heart scanners. When GE Healthcare was designing a scanner that was said to be the fas...[Details]
The particularity of portable medical devices determines that they should be user-friendly, must work in a sterile environment, and occupy little space and consume low energy.
At the same time, por...[Details]
Maximize instrument utilization and reduce
test times
Increasing the throughput of automated test systems can improve efficiency. Using off-the-shelf tools (COTS) such as multicore proc...[Details]
PCI (Perip heral Component Interconnect) is an advanced high-performance 32/64-bit local bus that supports linear burst transmission and has a maximum data transmission rate of 132MB/s. At the same...[Details]
As the price of readers and tags decreases and the global market expands, the application of radio frequency identification (RFID) is increasing day by day. Tags can be powered by readers (passive ...[Details]
As mobile phones have evolved from simple voice communication tools to multimedia devices that integrate communication, imaging, and gaming, application processors are replacing baseband chips as t...[Details]
TMS320C62X is a new generation of high-performance fixed-point digital signal processor (
DSP
) chip
from Texas Instruments (
TI
). The software design problem based on
DSP
is to use...[Details]
Multimedia communication terminal equipment has a wide range of application prospects and can be applied to various fields such as video conferencing, videophone, PDA, digital television, etc. Therefo...[Details]
0 Introduction
GaAs photocathode is a negative electron affinity photocathode with the advantages of high quantum efficiency, concentrated energy and angle distribution of emitted electrons. T...[Details]
Abstract:
The signal flow of the external transceiver in the WCDMA/TD-SCDMA protocol is analyzed. The analysis results show that most of the functional modules in the WCDMA/TD-SCDMA external tr...[Details]
Electrochemical Principles of Blood Glucose Measurement
The electro-biochemical principle of blood glucose measurement is that when a certain voltage is applied to the blood after the enzy...[Details]
The teardown of the third-generation iPhone shows that the phone is more integrated and may cost less, in part because of the use of chips from Broadcom and Toshiba. One analyst joked that the "S" ...[Details]