EEWORLDEEWORLDEEWORLD

Part Number

Search

2648LP/3A22101L110V1/3

Description
Rocker Switch, DPDT, Latched And Momentary, 10A, 12VDC, Quick Connect Terminal, V-shaped Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size230KB,8 Pages
ManufacturerAPEM
Environmental Compliance
Download Datasheet Parametric View All

2648LP/3A22101L110V1/3 Overview

Rocker Switch, DPDT, Latched And Momentary, 10A, 12VDC, Quick Connect Terminal, V-shaped Rocker Actuator, Panel Mount

2648LP/3A22101L110V1/3 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompli
ECCN codeEAR99
Actuator typeV-SHAPED ROCKER
body width18.5 mm
body height28.1 mm
Body length or diameter32 mm
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@12VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)12 V
Electrical life10000 Cycle(s)
illuminationBLUE LAMP
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature125 °C
Minimum operating temperature-20 °C
method of packingBULK
surface mountNO
Switch actionLATCHED AND MOMENTARY
switch functionDPDT
Switch typeROCKER SWITCH
Termination typeQUICK CONNECT
Base Number Matches1
2600 series
Illuminated and non-illuminated rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max. at 1A 2VDC
Models for peak currents
• Insulation resistance : 1.000 MΩ min. at 500VDC
Models 2600SLH with silver cadmium oxide contacts
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
are discontinued. They will be replaced by switches
3.000 Vrms 50 Hz min. between terminals and metal panel
with silver tin oxide contacts.
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +125°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-49
PIC16F877 reads DS1302 C program
PIC16F877 reads DS1302 C program, reads the time and displays it on the digital tube driven by 595...
liuduxin Microchip MCU
Does STM32 need an external EEPROM?
As the title says, some user data needs to be saved. Do I need to connect an external EEPROM?Can it be saved directly in the internal FLASH?Please advise....
wlck_8 stm32/stm8
How to burn NK to NAND FLASH for the first time after downloading it via USB?
How did the NK downloaded via USB burn to NAND FLASH for the first time? The OEMLanuch() function transferred to the WriteOSImageToBootMedia() function, but looking at the BSP source code of 2440 unde...
落寒残梦 Embedded System
Help: fat file system problem.
I formatted a 512M SD card with XP's fat32, and then read its partition table, which is the data at the 0x1be offset of sector 0, but I couldn't find the partition. Does anyone know why this is?...
jamy001 Embedded System
Intelligent power monitoring and protection system creative progress post + project creation and debugging in CubeSuite+ environment
[align=center][size=15.0pt]Project creation and debugging in CubeSuite+[/size][font=宋体][size=15.0pt]environment[/size][/font][/align][align=left][font=宋体]First step[/font][/align][align=left][font=宋体]...
ltbytyn Renesas Electronics MCUs
How to get files from USB disk in Linux system
The contents of the CD-ROM drive can be viewed by using a command: mount /mnt/cdrom. Why does it say /dev/fd0 is not a valid block device when I use mount /mnt/floppy after inserting the USB drive int...
呱呱 Linux and Android

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2593  39  1630  1053  1031  53  1  33  22  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号