Industrial and process control, distributed power, medical, ATE, communications,
defense and aerospace.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Parameter
+IN to –IN voltage
PC to –IN voltage
PR to –IN voltage
SC to –OUT voltage
Isolation voltage
IN to OUT
IN to base
OUT to base
Operating Temperature
Storage Temperature
Pin soldering temperature
Mounting torque
Rating
–0.5 to +53
–0.5 to +7.0
–0.5 to +7.0
–0.5 to +1.5
3000
1500
500
–55 to +100
–65 to +125
500 [260]
750 [390]
5 [0.57]
Unit
V
DC
V
DC
V
DC
V
DC
V
RMS
V
RMS
V
RMS
°C
°C
°F [°C]
°F [°C]
in.lbs [N.m]
Test voltage
Test voltage
Test voltage
M-Grade
M-Grade
<5 sec; wave solder
<7 sec; hand solder
6 each
Notes
Product Overview
These DC-DC converter modules use advanced
power processing, control and packaging
technologies to provide the performance,
flexibility, reliability and cost effectiveness of a
mature power component.
High-frequency ZCS / ZVS switching provides
high power density with low noise and
high efficiency.
[a]
Derate power to 75% for 9 – 10V
IN
.
Part Numbering
e.g. V28C12T100BL2
Note:
some configurations may not
be available.
28C
Product Grade Temperatures (°C)
Grade
Operating
Storage
C
= –20 to +100 –40 to +125
T
= –40 to +100 –40 to +125
H
= –40 to +100 –55 to +125
M
= –55 to +100 –65 to +125
B
Output Power
V
OUT
P
OUT
3.3V
50W
5V
50W
12V
100W
15V
100W
24V
100W
28V
100W
36V
100W
48V
100W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Product Type
V
= Standard
S
= Enhanced
efficiency
(avail. ≤12
V
OUT
only)
Output Voltage
3V3
= 3.3V
5
= 5V
12
= 12V
15
= 15V
24
= 24V
28
= 28V
36
= 36V
48
= 48V
Note:
Product images may not highlight current product markings.
28V Wide Micro Family
Page 1 of 12
Rev 3.0
03/2022
28V Wide Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
Module Input Specifications
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off / on
Disabled input current
36.3
8.8
8.5
37.8
12
39.6
14
Min
9
Typ
28
Max
36
50
8.9
Unit
V
DC
Notes
From 9 to 10V input available power is reduced to 75%
of max rating
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
<100ms
Module Output Specifications
Parameter
Output voltage set point
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
%
%
% / °C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 – 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to –OUT — Absolute Maximum Ratings
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
–0.5 to 4.7
–0.5 to 7.0
–0.5 to 10.9
–0.5 to 16.1
–0.5 to 20.0
–0.5 to 31.7
–0.5 to 36.9
–0.5 to 47.1
–0.5 to 62.9
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application information,
please refer to output connections on page 7.
Thermal Resistance and Capacity
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20265)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.24
0.21
10.9
2.8
48
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
28V Wide Micro Family
Page 2 of 12
Rev 3.0
03/2022
28V Wide Input
Module Family Electrical Characteristics (Cont.)
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
Module Control Specifications
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Figure 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
V
AVG
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figures 3 and 5
See Figure 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
Switch must be able to sink ≥4mA. See Figure 2
Module General Specifications
Parameter
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
Temperature limiting
Agency approvals
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
1.9
[52.8]
2.1
[58.7]
100
Min
3000
1500
500
10
2.1
[59.3]
2.3
[65.2]
115
cURus, cTÜVus, CE
2.3
[65.8]
2.5
[71.7]
Typ
Max
Unit
V
RMS
V
RMS
V
RMS
MΩ
ounces
[grams]
ounces
[grams]
°C
See Figures 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, in to baseplate, out to baseplate
28V Wide Micro Family
Page 3 of 12
Rev 3.0
03/2022
28V Wide Input
Module-Specific Operating Specifications
3.3V
OUT
, 50W (e.g. S28C3V3C50BL, V28C3V3C50BL)
Parameter
Efficiency
S28C3V3C50BL (enhanced efficiency)
V28C3V3C50BL (standard efficiency)
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
0
15.5
10.6
17.5
17.5
4.14
Min
73.7
72.0
Typ
83.6
73.4
180
4.3
5.2
±0.02
225
4.46
6.2
±0.2
15.15
20.6
20.6
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Output voltage 95% of nominal
Output voltage <250mV
Notes
Nominal input; 75% load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
5V
OUT
, 50W (e.g. S28C5C50BL, V28C5C50BL)
Parameter
Efficiency
S28C5C50BL (enhanced efficiency)
V28C5C50BL (standard efficiency)
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
0
10.2
7
11.5
11.5
6.03
Min
79.6
78.5
Typ
83.6
79.5
127
6.25
2.9
±0.02
159
6.47
3.5
±0.2
10
13.5
13.5
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Output voltage 95% of nominal
Output voltage <250mV
Notes
Nominal input; 75% load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
12V
OUT
, 100W (e.g. S28C12C100BL, V28C12C100BL)
Parameter
Efficiency
S28C12C100BL (enhanced efficiency)
V28C12C100BL (standard efficiency)
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
0
8.49
5.83
9.58
9.58
13.7
Min
82.0
81.0
Typ
85.0
82.3
200
14.3
6.8
±0.02
250
14.9
7.5
±0.2
8.33
11.3
11.3
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Output voltage 95% of nominal
Output voltage <250mV
Notes
Nominal input; 75% load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
28V Wide Micro Family
Page 4 of 12
Rev 3.0
03/2022
28V Wide Input
Module-Specific Operating Specifications (Cont.)
15V
OUT
, 100W (e.g. V28C15C100BL)
Parameter
Efficiency
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
0
6.8
4.66
7.67
7.67
17.1
Min
79.0
Typ
80.7
200
17.8
7.1
±0.02
250
18.5
10
±0.2
6.67
9.01
9.01
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Output voltage 95% of nominal
Output voltage <250mV
Notes
Nominal input; 75% load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
24V
OUT
, 100W (e.g. V28C24C100BL)
Parameter
Efficiency
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
81.3
27.1
Typ
82.3
180
28.1
5.3
±0.02
4.8
4.8
Max
225
29.1
6.2
±0.2
4.17
5.63
5.63
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; 75% load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
4.25
2.91
28V
OUT
, 100W (e.g. V28C28C100BL)
Parameter
Efficiency
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
0
3.64
2.49
4.11
4.11
31.5
Min
79.0
Typ
80.6
160
32.7
7.6
±0.02
200
33.9
8.3
±0.2
3.57
5.35
5.85
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Output voltage 95% of nominal
Output voltage <250mV
Notes
Nominal input; 75% load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
I am a mechanical major, and my graduation project is the speed control of a pneumatic manipulator. I want to use DSP as the controller, but I have only been in contact with DSP for more than a month....
I want to learn how to read and write memory and ports recently, but I have encountered several problems. I hope an expert can give me some advice: 1. With 2G memory, what is the maximum memory addres...
Data storage: Pointer type is 16 bits. Floating point types (float, double, long double) are all 32 bits. All 32-bit types (long float, etc.) are stored with the low bit first and the high bit last. D...
Can Quartus II 10.1 directly export schematics? Thank you. If it can be exported, how do I do it? If it can't be exported, everyone draws it by themselves or is there any simple method?...
The rapid development of the Internet has realized high-speed information transmission and resource sharing, greatly facilitating people's lives. Embedded systems are widely used in various electr...[Details]
introduction
Solar cells and LED lighting are typical applications of new energy and energy-saving and efficient technologies. Solar LED lighting uses solar cells to convert solar energy...[Details]
Editor's note: In order to help technicians or engineers who have knowledge of PIC microcontroller assembly language quickly master the method of using C language to program PIC microcontrollers, t...[Details]
LED lamps and bulbs are now rapidly replacing incandescent, halogen and CFL (compact fluorescent lamp) light sources in many general lighting applications. Flyback DC/DC converters are the power su...[Details]
Capacitance Measurement
Used to verify that capacitors meet the manufacturer's specifications. For quality control, a group of capacitors may be placed in an environmental chamber and the cap...[Details]
Motors are important products that convert electrical energy into mechanical energy to achieve automation, and they are widely used in industrial control, medical electronics, white a...[Details]
Introduction
Automakers are working to reduce vehicle weight to reduce CO2 emissions and improve fuel efficiency. Designers are therefore seeking new technologies and design techniques that can...[Details]
At present, how various communication technologies will evolve after 3G is a focus of great concern in the industry. Especially for TD-SCDMA, whether it can achieve smooth evolution to the next gen...[Details]
The invention of the steam engine ushered in the first conversion of internal energy and mechanical energy for mankind, and the birth of the internal combustion engine at the end of the 19th centur...[Details]
1 Development of LED Film and Television Lighting
1.1 The significance of developing film and television lighting
Lighting power consumption accounts for a large proportion of the total p...[Details]
In order to prevent the lithium battery from being damaged by abnormal conditions such as overcharge, over discharge, and overcurrent, a lithium battery protection device is usually used to prevent...[Details]
Mobile phones, MP3s, tablet computers, laptops, digital cameras, handheld game consoles, navigation devices, etc., all these mobile devices are powered by mobile batteries, and the battery life is ...[Details]
1 Introduction
Fieldbus is a serial, digital, multi-point communication data bus between field equipment/instruments installed in the production process area and automatic control devices/syst...[Details]
The biggest advantage of Profibus is that it is guaranteed by the stable international standard EN50170 and has been proven to be universal in practical applications. It has been widely used in man...[Details]
The programmable controller directly controls the stepper motor, which can significantly reduce the cost of the control system of the modular machine tool automatic production line. The article int...[Details]