A.
Construction
1) Component 1
a) Conductor
b) Insulation
(1) Print
(2) Color Code
Cond
1
2
3
Color
GREEN/YELLOW
BLACK#1
BLACK#2
CUSTOMER PRODUCT SPECIFICATION
Issue:
Issue Date:
Effective Date:
1
3/24/2015
5/19/2015
Diameters (In)
9 X 1 COND
18 (41/34) AWG Tinned Copper
0.043
0.010" Wall, Nom. MPPE
0.063
ALPHANUMERIC NUMBERS - 1-ONE ALTERNATING AND
INVERTED
Alpha Wire Color Code KX
Cond
4
5
6
Color
BLACK#3
BLACK#4
BLACK#5
Cond
7
8
9
Color
BLACK#6
BLACK#7
BLACK#8
2)
3)
Cable Assembly
a) Twists:
b) Core Wrap
Jacket
a) Color(s)
b) Print
9 Components Cabled
4.0 Twists/foot (min)
Nonwoven Polyester Tape, 25% Overlap, Min.
0.032" Wall, Nom.,Polyurethane, Zero Halogen (ZH)
0.318+/- 0.015
SLATE
ALPHA WIRE-* P/N 80037 9C 18 AWG
RU AWM STYLE 21959 90C 600V SUN RES 60C OIL OR
CRU AWM I/II A/B 90C 600V FT2 --- IEC EN 60332-1/2
CE
ROHS
(SEQ FOOTAGE)
* = Factory Code
B.
Applicable Specifications
1) UL
a) Component 1
b) Overall
2)
3)
CSA International
IEC
a) Component 1
b) Overall
AWM/STYLE 11231
AWM/STYLE 21959
60C OIL
SUN RES
C(RU) AWM I/II A/B
FT2
105°C / 600 V
RMS
90°C / 600 V
RMS
90°C / 600 V
RMS
C.
D.
E.
EU Directive 2011/65/EU(RoHS2):
This product complies with European Directive 2011/65/EU (RoHS Directive) of the
European Parliament and of the Council of 8 June 2011. No Exemptions are
required for RoHS Compliance on this item. Consult Alpha Wire's web site
for
RoHS C of C.
2) REACH Regulation (EC 1907/2006):
This product does not contain Substances of Very High Concern (SVHC) listed on
the European Union's REACH candidate list in excess of 0.1% mass of the item. For
up-to-date information, please see
Alpha's REACH SVHC Declaration.
Physical & Mechanical Properties
1) Temperature Range
-50 to 90°C(static), -40 to 80°C (dynamic)
2) Bend Radius
4X Cable Diameter(static), 6X Cable Diameter(dynamic)
3) Pull Tension
115 Lbs, Maximum
4) Sunlight Resistance
Yes
Electrical Properties
(For Engineering purposes only)
1) Voltage Rating
600 V
RMS
4) CE:
Environmental Compliance
1) CE:
EN 60228 Conductors, Class 6
EN 60754-1 Acid Gas Generation
EN 60754-2 Acid Gas Generation
EN 60332-1 Flame Behavior
EN 60332-2 Flame Behavior
EU Low Voltage Directive 2006/95/EC
Although Alpha Wire Company ("Alpha") makes every reasonable effort to ensure their accuracy at the time of publication, information and specifications
described herein are subject to errors or omissions and to changes without notice, and the listing of such information and specifications does not ensure
product availability.
Alpha provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In
no event will Alpha be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary) whatsoever, even if Alpha has
been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the
use, or inability to use, the information or specifications described herein.
711 Lidgerwood Ave Elizabeth, NJ 07207-0711
Toll Free 1-800-52 ALPHA • T: 1-908-925-8000 • F: 908-925-5411 • Email: info@alphawire.com
www.alphawire.com
Comparison between MDK and ADS
[table=98%][tr][td][table=98%][tr][td][table=98%][tr][td][table=90%][tr][td][table=95%][tr][td=3,1][font=宋体]1[/font][font=宋体]) ADS was phased out in 2000, and ARM stopped production in 2001. [/font] [...
ye0217 Embedded System
Summary of graduation design topics for electronics majors (more than 550 topics for you to choose from)
[color=#000000][size=10.5pt][size=10.5pt]labVIEW[/size][/size][font=宋体][size=10.5pt]Design and implementation of virtual filter[/size][/font][size=10.5pt][size=10.5pt] 3.[/size][/size][font=宋体][size=1...
tiankai001 MCU
After working normally for a year, can I take five days of annual leave according to the Labor Law?
After working normally for a year, can I take five days of annual leave according to the Labor Law?...
moqiemoqie Talking about work
Building Automation System Interoperability with KNX Software on Ultra-Low-Power MCUs
[align=left][color=#000]Automation systems are becoming more common and more important in buildings of varying sizes and complexity. Convenience, safety and energy efficiency are key drivers for smart...
maylove Microcontroller MCU
How to set Wince 5.0 so that the Folder Options-->Advanced Settings item is not selected
How to set the Folder Options-->Advanced Settings item in Wince 5.0 to be unchecked? It is checked by default. Where can I modify it to make it unchecked? What value is set to 0?...
wu1239 Embedded System
What knowledge do you need to develop LCD ICs?
What knowledge do I need to do LCD IC development? Maybe a learning curve sequence?...
flyingzero Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2877  1979  2782  20  2299  58  40  57  1  47 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号