2631LH/2C21608L380V/3

Description
Rocker Switch, SPST, Latched, 15A, 12VDC, Solder/quick Connect Terminal, Plain Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size229KB,8 Pages
ManufacturerAPEM
Environmental Compliance
Download Datasheet Parametric View All

2631LH/2C21608L380V/3 Overview

Rocker Switch, SPST, Latched, 15A, 12VDC, Solder/quick Connect Terminal, Plain Rocker Actuator, Panel Mount

2631LH/2C21608L380V/3 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompli
ECCN codeEAR99
Actuator typePLAIN ROCKER
body width18.5 mm
body height28.1 mm
Body length or diameter32 mm
Contact (AC) maximum rated R load16A@250VAC
Maximum contact current (AC)16 A
Maximum contact current (DC)15 A
Contact (DC) maximum rated R load15A@12VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)12 V
Electrical life10000 Cycle(s)
illuminationRED LAMP
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature55 °C
Minimum operating temperature-10 °C
method of packingBULK
sealDUST PROOF; WATER PROOF
surface mountNO
Switch actionLATCHED
switch functionSPST
Switch typeROCKER SWITCH
Termination typeSOLDER/QUICK CONNECT
Base Number Matches1
2600 series
Illuminated and non-illuminated rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max. at 1A 2VDC
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +125°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-49
Sensors seeking guidance
I am a beginner, a complete beginner, just started in this field, please help me! There are a few things below, I only know they are sensors, but I don't know what they are, nor do I know how to use t...
idvi Sensor
National Electric Power Equipment Jiangsu Seminar Conference Documents
[i=s]This post was last edited by paulhyde on 2014-9-15 09:40[/i] Same as above, including some analysis and predictions for this competition...
haozi_1989 Electronics Design Contest
Screen.PrimaryScreen.WorkingArea cannot obtain the working area
As the title states, what is obtained is the height and width of the device screen, including the workbar. What WorkingArea obtains is the working area, but does not include the workbar?...
zhengyusun Embedded System
Christmas is coming
Christmas is coming soon. What are some good activities for you? What do you think about Christmas? It seems that this foreign festival is becoming more and more popular, even surpassing many traditio...
张无忌1987 Talking
data verification failed at address 0x0 please verify target memory and memory m
data verification failed at address 0x0 please verify target memory and memory map\\My build has passed but when I load the program, this prompt appearsI am tuning the self-generated example wave...
hhhhwangba Analogue and Mixed Signal
What is the correspondence between ce.bib and virtual memory?
Hello seniors! I have encountered some difficulties in understanding the debugging of ce.bib in CE6.0. I hope you can answer my questions.... I checked the configuration in ce.bib: NK 80220000 009E000...
heyan0902 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 999  1675  2266  2736  554  21  34  46  56  12 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号