Ø7.5
x11.5mm)
3-Electrode Gas Discharge Tubes
1:Dimension(mm)
10KA
Fast Delivery Time
2:Main Applications
•PCI Cards protection
•Telephone/Fax/Modem protection
•single line protection
•ADSL/XDSL Splitter,Power Supply
•Surge Protection Device/Surge Protector
4 Electrical Characteristics
DC
Spark-over
Voltage
@ 100V/S
V
HA3R75G
HA3R90G
HA3R150G
HA3R230G
HA3R250G
HA3R300G
HA3R350G
HA3R400G
HA3R420G
HA3R470G
HA3R600G
HA3R800G
75±20%
90±20%
150±20%
230±20%
250±20%
300±20%
350±20%
400±20%
420±20%
470±20%
600±20%
800±20%
Impulse
Spark-over
Voltage
@100V/
μs
V
<500
<500
<500
<600
<600
<800
<900
<900
<900
<1100
<1200
<1300
Impulse
Spark-over
Voltage
@1KV/
μs
V
<600
<600
<600
<700
<700
≤ 900
≤ 1000
≤ 1000
≤ 1000
≤ 1200
≤ 1300
≤ 1400
3:Features
•
100% Lead-Free(
RoHs Compliant )
•Non-Radioactive
•Low capacitance (≤1pF)
•Fast Response-time,High Insulation Resistance.
•Small size :Ø7.5x11.5(mm)
Insulation
Resistance
Impulse
discharge
current(
8
AC discharge
current
(50Hz,1s,10ti
mes)
Part Number
Capacitan
ce
(1MHz)
PF
≤1
≤1
≤1
≤1
≤1
≤1
≤1
≤1
≤1
≤1
≤1
≤1
/20
μs
)
GΩ
>1
>1
>1
>1
>1
>1
>1
>1
>1
>1
>1
>1
10 Times
A
10
10
10
10
10
10
10
10
10
10
10
10
10KA
10KA
10KA
10KA
10KA
10KA
10KA
10KA
10KA
10KA
10KA
10KA
1
Revised:February 25,2014
www.huaandz.com
Table continues on next page