ACE Series
OPEN FRAME & ENCLOSED
3 0 0 - 9 0 0 W AT T S - A C / D C M O D U L A R O U T P U T
FEATURES
•
•
•
•
Flexible modular system architecture provides
various output configurations.
Harmonic attenuator (Complies with IEC61000-3-2).
Universal input (85-264Vac).
Remote on/off controls, alarm.
INPUT
ENVIRONMENTAL
Voltage
Frequency
Leakage current
Inrush current
Isolation
85-264VAC or 120-350VDC.
47-63Hz.
0.5mA (ACIN100V), 0.95mA (ACIN230V)
Cold start, 15A/30A @ 115VAC
Cold start, 30A/30A @ 230VAC.
In/Out 3kVac.
In/Gnd 2kVac.
Out/Gnd 500Vac.
See table.
See table.
See table.
See table for individual modules.
ACE300F: 250W/300W
ACE450F: 400W/450W
ACE650F: 600W/650W
ACE900F: 800W (1KW peak) / 900W (1KW
peak).
ACE300F: 4
ACE450F: 5
ACE650F: 5
ACE900F: 6
See table.
See table.
See table.
115% - 140% of rated voltage.
Over 105% min. of rated current.
500ms max.
20ms typical.
78%-80% typical.
Operating temperature
Humidity
Vibration
Impact
STANDARDS
-20°C to 70°C (Refer to derating curve)
Consult Powerbox office.
20 – 75% RH Non-Condensing
19.6m/s2 (2G) 10Hz-55Hz 3 minutes x, y and z
axes 60 minutes
196.1m/s2 (20G), 11ms once along x, y and z
axes
EN60950-1, EN50178, UL60950-1 and C-UL
IEC60950 and DEN-AN (AC input only)
Marking Complies with LVD and EMC Directives
AS/NZS CISPR11 Group 1, Class A
Complies with FCC-B, CISPR22-B,
EN55022-B, VCCI-B
Complies with EN61000-4-2,EN61000-4-3,
EN61000-4-4, EN61000-4-5, EN61000-4-6,
EN61000-4-8 and EN61000-4-11
Complies with IEC61000-3-2.
ACE300F: 103x63.5x254mm (WxHxD).
ACE450F: 127x63.5x254mm (WxHxD).
ACE650F: 127x63.5x279mm (WxHxD).
ACE900F: 177.5x63.5x256mm (WxHxD).
ACE300F: 1.7kg max.
ACE450F: 2.2kg max.
ACE650F: 2.4kg max.
ACE900F: 3.0kg max.
OUTPUT
Safety standards
CE
C Tick
EMI standards
EMC standards
Output voltage
Voltage adjustment
Output current
Output power
(110/230Vin)
Input Harmonics
MECHANICAL
Number of slots
Dimensions
Ripple & noise
Line regulation
Load regulation
Over voltage protection
Over current protection
Startup time
Holdup time
Efficiency
Weight
76
Doc. No. PBC9 Rev.D 10-8-12
ACE Series
3 0 0 - 9 0 0 W AT T S - A C / D C M O D U L A R O U T P U T
OPEN FRAME & ENCLOSED
150W SUITABLE SINGLE OUTPUT
ITEM
CODE
A
B
C
D
E
F
G
H
J
K
50W SUITABLE SINGLE OUTPUT
L
M
N
P
R
75W DUAL OUTPUT
Y*7
W*7
Z*7
9*7
Number of slots used
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Voltage
2 3.3 5 7.5 12 15 18 24 34 48 3.3
5
12
15
24
Minimum current
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Current1(A)
26 26 26 18 13 10 8.5 6.5 4.5 3.2 10
10
5
4
2.5
Current2(A)
— — — — — — — — — — —
—
—
—
—
Peak current(A)*1
— — — — 14 12 10
8 5.5 4
—
—
—
—
—
Line regulation(mV)max
20 20 20 36 48 60 72 96 120 192 20
20
48
60
96
Load regulation1(mV)max*5
40 40 40 100 100 120 120 150 180 300 40
40 100 120 150
Load regulation2(mV)max*6
— — — — — — — — — — —
—
—
—
—
0 to +50°C*2 80 80 80 120 120 120 120 120 120 150 80
80 120 120 120
Ripple
(mVp-p)max
-20 to 0°C*2 140 140 140 160 160 160 160 160 160 300 140 140 160 160 160
0 to +50°C*2 120 120 120 150 150 150 150 150 150 350 120 120 150 150 150
Ripple Noise
(mVp-p)max
-20 to 0°C*2 160 160 160 180 180 180 180 180 180 400 160 160 180 180 180
Temp Coeff. (mV)max
0 to +50°C
50 50 50 90 120 150 180 240 300 480 50
50 120 150 240
Drift (mV)max*6
20 20 20 36 48 60 72 96 120 192 20
20
48
60
96
2.00- 3.25- 4.99- 7.20- 11.5- 14.4- 17.3- 23.0- 33.0- 46.0- 3.25- 4.99- 11.5- 14.4- 23.0-
Output voltage setting(V)
2.20 3.45 5.30 7.80 12.5 15.6 18.7 25.0 35.0 50.0 3.45 5.30 12.5 15.6 25.0
Output voltage adjustment
1.60- 2.60- 4.00- 6.00- 9.00- 13.2- 16.5- 19.2- 27.2- 38.4- 2.60- 4.00- 9.00- 13.2- 19.2-
range(V)*4
2.60 3.60 5.50 8.20 13.2 16.5 19.2 26.4 37.4 52.8 3.60 5.50 13.2 16.5 26.4
Overcurrent protection(A)
Works over 105% min of rated current or 101% min of peak current. Automatic recovery
3.00- 4.00-
4.00- Works at 115%-140% of
Overvoltage protection(V)
Works at 115%-140% of rated voltage
4.80 5.25
5.25 rated voltage
Function
Remote sensing, remote ON/OFF, alarm(LV)
Remote ON/OFF, alarm(LV)
1
±5
0
3
7
5
20
250
500
80
140
120
160
50
20
4.99-
5.30
4.99-
6.00
1
±12
0
3.2
4.2
4
48
600
750
120
160
150
180
120
48
11.5-
12.5
9.60-
13.2
1
±15
0
2.5
3.5
—
60
600
750
120
160
150
180
150
60
14.5-
15.6
13.2-
16.5
1
±24
0
1.6
2.5
—
60
600
750
120
160
150
180
150
60
23.0-
25.0
19.2-
26.4
6.90- 13.8- 17.2- 27.6-
8.40 16.8 21.0 33.6
300W SUITABLE SINGLE OUTPUT
ITEM
CODE
2A
2B
2C
2D
2E
2F
2G
2H
2J
2K
100W SUITABLE DUAL OUTPUT
S
T
U
150W DUAL
OUTPUT
W
Z
*
I
1
Number of slots used
2
2
2
Voltage
2 3.3 5
Minimum current
0
0
0
Current1(A)
60 60 60
Current2(A)
— — —
Peak current(A)*1
— — —
Line regulation(mV)max
20 20 20
Load regulation1(mV)max*5
40 40 40
Load regulation2(mV)max*6
— — —
0 to +50°C*2 80 80 80
Ripple
(mVp-p)max
-20 to 0°C*2 140 140 140
0 to +50°C*2 120 120 120
Ripple Noise
(mVp-p)max
-20 to 0°C*2 160 160 160
Temp Coeff. (mV)max 0 to +50°C
50 50 50
Drift (mV)max*6
20 20 20
Output voltage setting(V)
Output voltage adjustment
range(V)*4
Overcurrent protection(A)
Overvoltage protection(V)
Function
2.00-
2.20
1.60-
2.60
3.25-
3.45
2.60-
3.60
4.99-
5.30
4.00-
5.50
2
7.5
0
40
—
—
36
100
—
120
160
150
180
90
36
7.20-
7.80
6.00-
8.20
2
12
0
25
—
34
48
100
—
120
160
150
180
120
48
11.5-
12.5
9.00-
13.2
2
15
0
20
—
27
60
120
—
120
160
150
180
150
60
14.4-
15.6
13.2-
16.5
2
18
0
17
—
23
72
120
—
120
160
150
180
180
72
17.3-
18.7
16.5-
19.2
2
24
0
14
—
20
96
150
—
120
160
150
180
240
96
23.0-
25.0
19.2-
26.4
2
34
0
10
—
14
120
180
—
120
160
150
180
300
120
33.0-
35.0
27.2-
37.4
2
48
0
7
—
10
192
300
—
150
300
350
400
480
192
46.0-
50.0
38.4-
52.8
1
V1; 5 V1; 5
0
0
10
5
— —
— —
20 20
40 40
— —
80 80
140 140
120 120
160 160
50 50
20 20
1
V1; 5 V1; 12
0
0
10 4.2
— —
— —
20 48
40 100
— —
80 120
140 160
120 150
160 180
50 120
20 48
1
V1; 5 V1; 24
0
0
10 2.1
— —
— —
20 96
40 150
— —
80 120
140 160
120 150
160 160
50 240
20 96
1
±12
0
6.4
8
10
48
600
750
140
200
230
350
120
48
1
±15
0
5.5
7
8
60
600
750
140
200
230
350
150
60
Input module
4.99- 4.99- 4.99- 11.5- 4.99- 23.0- 11.5-
14.4-15.6
5.30 5.30 5.30 12.5 5.30 25.0 12.5
4.99- 3.00- 4.99- 7.50- 4.99- 15.0- 9.60-
13.2-16.5
5.50 5.50 5.50 13.2 5.50 26.4 13.2
Works over 105% min of rated current or 101% min of peak current. Automatic recovery
3.00- 4.00-
4.80 5.25
Works at 115%-140% of rated voltage
Remote ON/OFF
Same as W, Z
Remote sensing, remote ON/OFF, alarm(LV)
4.2 for details.)
—
*1 Operating condition of peak current : Peak current is less than 10sec., duty is less than 35% and average current is less than
rated current. (rated current2 at Module W, Z, 9, Q and V)
*2 Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN : RM101). Ripple and Ripple Noise is
measured by using measuring board with capacitor of 22mF within 150mm from output terminal.
*3 Drift is changed in DC output for an eight hour period after half-hour warm-up at 25C, with the input voltage held constant at
the rated input/output.
*4 When the output voltage of module A is used less than 2.0V, keep minimum output current 2.6A.
*5 It is a value from 0 to rated output current1. The current on non-measurement side is fixed.
*6 It is a value from 0 to rated output current2. The current on non-measurement side is fixed.
*7 The sum of +power and -power must be less than output power(Y:50W, W:76.8W, Z:75W, 9:76.8W, Q:153.6W, V:165W).
*8 Ratings of V2 can draw up to 50% of rated current at the time of 0A in load of V1.(Only module S,T,U. refer to instruction manual
* Each output of module Y-Z, 9, Q and V is a ground common type (not isolated),each output ofmodule S,T and U is isolated.
= For ACE300F,450F and 650F , input and output terminals can be set at the same side if Input module (code:I) is installed
instead of the most left module.
* Modules which can correspond to medical electrical equipment (UL2601-1, EN60601-1) are all modules except module S, T
and U. Refer to instruction manual 7. for details.
Doc. No. PBC9 Rev.D 10-8-12
Powering Progress – www.powerbox.com.au
77