18W AC-DC High Reliability Industrial Adaptor
GST18B
series
THOMAS SAMUEL
THOMAS SAMUEL
IS13252 K60950-1 TPTC004
UL60950-1
EN60950-1
J60950-1
CNS14336 AS/NZS60950-1
GB4943 MS IEC60950-1 IEC60950-1
(optional)
■
Features
Global certificates
Universal AC input / Full range
2 pole AC inlet IEC320-C8,Class
Ⅱ
power unit
No load power consumption< 0.075W
Energy efficiency Level VI
Comply with EISA 2007/DoE,NRCan,Korea K-MEPS,
AU/NZ MEPS,EU ErP and CoC Version 5
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
Pass LPS
-30~+70
℃
wide range working temperature
LED indicator for power on
3 years warranty
■
Applications
Consumer electronic devices
Telecommunication devices
Office facilities
Industrial equipments
■
Description
GST18B is a highly reliable, 18W desktop style single-output green adaptor series. This product is a class
Ⅱ
power unit (no FG), equipped with a standard IEC320-C8 AC inlet and adopting the input range from
85VAC to 264VAC. The entire series supplies different models with output voltages ranging between
5VDC and 48VDC that can satisfy the demands for various types of consumer electronic devices.
With the efficiency up to 89% and the extremely low no-load power consumption below 0.075W,GST18B is
compliant with USA EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS,Korea K-MEPS ,EU ErP,and
Code of Conduct(CoC) Version 5
. The supreme feature allows the adaptor to save the energy when it is
either under the operating mode or the standby mode. The entire series utilizes the 94V-0 flame retardant
plastic case, providing the double insulation that effectively prevents electrical shock. GST18B is certified
for the international safety regulations.
■
Model Encoding
GST 18 B 05 - P1J
DC plug type
Output voltage
IEC320-C8 AC inlet
Rated wattage
Series name
File Name:GST18B-SPEC 2017-05-05
{
P1J: Standard model,2.1
ψ
x5.5
ψ
x11mm,C+,tuning fork type
Other options available by customer requested (see Page 4~5)
18W AC-DC High Reliability Industrial Adaptor
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
OUTPUT
GST18B
GST18B15
15V
1.20A
0 ~ 1.20A
18W
100mVp-p
±3.0%
±1.0%
±3.0%
GST18B18
18V
1.0A
0 ~ 1.0A
18W
150mVp-p
±3.0%
±1.0%
±3.0%
GST18B24
24V
0.75A
0 ~ 0.75A
18W
150mVp-p
±2.0%
±1.0%
±2.0%
GST18B28
28V
0.64A
0 ~ 0.64A
18W
150mVp-p
±2.0%
±1.0%
±2.0%
series
GST18B05-P1J GST18B07-P1J GST18B09-P1J GST18B12-P1J GST18B15-P1J GST18B18-P1J GST18B24-P1J GST18B28-P1J GST18B48-P1J
GST18B05
Note.2
5V
GST18B07
7.5V
2.0A
0 ~ 2.0A
15W
80mVp-p
±5.0%
±1.0%
±5.0%
GST18B09
9V
2.0A
0 ~2.0A
18W
80mVp-p
±5.0%
±1.0%
±5.0%
GST18B12
12V
1.50A
0 ~ 1.50A
18W
80mVp-p
±3.0%
±1.0%
±3.0%
GS18B48
48V
0.375A
0 ~ 0.375A
18W
150mVp-p
±2.0%
±1.0%
±2.0%
3.0A
0 ~ 3.0A
15W
RIPPLE & NOISE (max.)
Note.3
80mVp-p
VOLTAGE TOLERANCE
Note.4
±5.0%
LINE REGULATION
LOAD REGULATION
Note.5
±1.0%
Note.6
±5.0%
SETUP, RISE, HOLD UP TIME
1000ms, 30ms, 50ms/230VAC
Note.7
85 ~ 264VAC
VOLTAGE RANGE
FREQUENCY RANGE
INPUT
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
47 ~ 63Hz
81%
0.5A / 115VAC
0.25mA / 240VAC
85%
85%
0.3A / 230VAC
1500ms, 30ms, 15ms/115VAC at full load
86%
87%
88%
88%
88.5%
89%
Cold start 35A / 115VAC
65A / 230VAC
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
110 ~ 140% rated output voltage
Protection type : Clamp by zener diode, output short
-30 ~ +70
℃
(Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-40 ~ +85
℃
, 10 ~ 95% RH non-condensing
±
0.03% /
℃
(0 ~ 50
℃
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS Note. 8
UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943,AS/NZS 60950.1,PSE J60950-1, BIS IS13252,
KC K60950-1,
EAC TP TC 004 approved; SIRIM MS IEC60950-1 (optional)
approved
WITHSTAND VOLTAGE
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25
℃
/ 70% RH
ISOLATION RESISTANCE
Parameter
Conducted emission
Standard
Test Level / Note
EN55032(CISPR32),FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1
Class B
EAC TP TC 020,MSIP KN32
EN55032(CISPR32),FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1
Class B
EAC TP TC 020,MSIP KN32
EMC EMISSION
Radiated emission
SAFETY &
EMC
(Note. 9)
Harmonic current
Voltage flicker
Parameter
ESD
RF field
susceptibility
EMC IMMUNITY
EFT bursts
Surge susceptibility
Conducted susceptibility
Magnetic field
immunity
EN61000-3-2,GB9254
EN61000-3-3
Standard
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
Class A
-------
Test Level /Note
Level 3, 8KV air; Level 2, 4KV contact
Level 2, 3V/m
Level 2, 1KV
Level 4, 2KV/Line-Line
Level 2, 3V
Level 2, 3A/m
>
95% dip 0
.
5 periods, 30% dip 25 periods,
>
95% interruptions 250 periods
Voltage dips , interruption
MTBF
DIMENSION
PACKING
PLUG
CABLE
500Khrs min. MIL-HDBK-217F(25
℃
)
79*54*33mm (L*W*H)
191.5g; 60pcs/12.5Kg/1.22CUFT
See page 4~5 ; Other type available by customer requested
See page 4~5 ; Other type available by customer requested
OTHERS
CONNECTOR
NOTE
1.All parameters are specified at 230VAC input, rated load, 25
℃
70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1 f & 47 f capacitor.
μ
μ
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load.
7.Derating may be needed under low input voltage. Please check the derating curve for more details.
8.The demand for Malaysia safety is processed with the order no. GST18B
-SIRIM by request. Please contact MEAN WELL for details.
9.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
File Name:GST18B-SPEC 2017-05-05
18W AC-DC High Reliability Industrial Adaptor
GST18B
A
OD
5
.
5
6.5
7.4
B
ID
3.4
4.4
C
L
11.0
11.0
D
series
Center Pin Style
A
B
D
Type No.
C
Center Pin
P4A
P4B
P4C
Type No.
1.0
1.4
EIAJ equivalent
Min. DIN 3 Pin with Lock (male)
1
2
3
11.0
0.6
5.1
Pin Assignment
Output
PIN No.
+Vo
1
2
3
-Vo
+Vo
Pin Assignment
Output
PIN No.
+Vo
1
-Vo
2
3
-Vo
4
+Vo
Pin Assignment
Output
PIN No.
+Vo
1
-Vo
2
3
-Vo
4
+Vo
Pin Assignment
Output
PIN No.
-Vo
1
-Vo
2
3
+Vo
-Vo
4
5
+Vo
Pin Assignment
Output
PIN No.
R6B
KYCON
KPPX
-
3P equivalent
Min. DIN 4 Pin with Lock (male)
2 3
1 4
KYCON
KPPX
-
4P equivalent
Type No.
R7B
Min. DIN 4 Pin with Lock (female)
Type No.
23
14
KYCON KPJX-CM-4S equivalent
R7BF
DIN 5 Pin (male)
Type No.
3
1
4 2 5
R1B
Stripped and tinned leads
L
(red)
Type No.
1
2
L1
(black)
by customer
Length of Land L1 by request
( MW’s standard length, L: 25 mm, L1: 5 mm)
1
+Vo
2
-Vo
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
File Name:GST18B-SPEC 2017-05-05