Surge Protection Circuit, PACKAGE-3

2020-15T-C4 Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
Parts packaging codeMODULE
package instruction,
Contacts3
Reach Compliance Code_compli
JESD-30 codeX-XXSS-X3
Number of functions1
Number of terminals3
Maximum operating temperature90 °C
Minimum operating temperature-40 °C
Package body materialUNSPECIFIED
Package shapeUNSPECIFIED
Package formSPECIAL SHAPE
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
Telecom integrated circuit typesSURGE PROTECTION CIRCUIT
Temperature levelINDUSTRIAL
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Base Number Matches1
*R
oH
VE S CO
AV R M
AI SIO PL
LA N IA
BL S NT
E
Features
Fast acting
Balanced
Stable breakdown throughout life
Designed to operate with TBU devices
®
Applications
Telecommunications
Industrial electronics
Avionics
RoHS compliant* versions available
2020 T Series - 3-Pole Fast Gas Discharge Tube
Characteristics
Model No.
2020-15T
2020-23T
2020-42T
Characteristic
Minimum DC Sparkover
(100 V/s)
Throughout Service Life
60 V
500 V
180 V
650 V
360 V
850 V
Maximum Impulse Sparkover (5k V 1.2/50 µs)
Throughout Service Life
Impulse Transverse Delay...................1000 V/µs ............................................................................... < 75 ns
Insulation Resistance (IR) ...................50 V / 100 V ............................................................................ > 10
9
Ω
Glow Voltage ......................................10 mA ..................................................................................... ~ 70 V
Arc Voltage .........................................>1 A ........................................................................................ ~ 10 V
Glow-Arc Transition Current ............................................................................................................... < 0.5 A
Capacitance .......................................1 MHz ..................................................................................... < 1 pF
DC Holdover Voltage (Network Applied per ITU-T K.12)
2020-15T .......................................52 V ........................................................................................ < 150 ms
2020-23T .......................................80 V ........................................................................................ < 150 ms
2020-42T .......................................135 V ...................................................................................... < 150 ms
Service Life
1
.......................................8/20 µs, 5 kA .......................................................................... 1 operation
10/1000 µs, 1 kV, 100 A.......................................................... 100 operations
2
2/10 µs, 5 kV, 1000 A.............................................................. 10 operations
2
10/700 µs, 6 kV, 150 A............................................................ 50 operations
2
8/20 µs, 500 A, 1.2/50 µs, 500 V ............................................ 150 operations
2
600 V, 5 Arms, 0.2 sec. ........................................................... 10 operations
600 Vrms, 0.5 A - 60 A ........................................................... Fail-Short activates
3
230 Vrms, 0.5 A-25 A ............................................................. Fail-Short activates
3
Operating and Storage Temperature .................................................................................................. -40 to +90 °C
Climatic Category (IEC 60068-1) ....................................................................................................... 40 / 90 / 21
Notes:
1 Applied per conductor to center pin.
2 Surge polarity should be reversed between consecutive surges (+,-,+,-)
3 Applies only to GDT with optional Fail-Short. GDT operates and will survive with Fail-Short activation.
• At delivery AQL 0.65 Level II, DIN ISO 2859.
Applications
Port Protection
CanBus
RS232
RS422
RS485
RS485
SDI
VDSL
GDT Device P/N
2020-23T
2020-23T
2020-23T
2020-23T
2020-42T
2020-23T
2020-15T
TBU
®
Device P/N
TBU-CA065-100-WH
TBU-CA065-200-WH
TBU-CA065-200-WH
TBU-CA065-200-WH
TBU-CA085-200-WH
TBU-CA065-100-WH
TBU-CA050-500-WH
“TBU” is a registered trademark of Bourns, Inc. in the U.S., Taiwan and European Community.
*RoHS Directive 2002/95/EC Jan 27, 2003 including Annex.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
AVR interrupt problem? ? ? ? ? ? ? ? ? Urgent Urgent Urgent
Why does the AVR C program keep re-executing the main() function after any interrupt is enabled? ? Tip: No interrupt routines are defined in advance. Thank you very much! Please email to lijian_8010a2...
buliaoren Embedded System
【CN0187】Crest Factor, Peak and RMS RF Power Measurement Circuit Optimized for Low Power Consumption and 3.3V Single Supply
Circuit Function and Advantages The circuit shown in Figure 1 measures peak and rms power at any RF frequency from 450 MHz to 6 GHz with approximately 45 dB of dynamic range. The measurement result is...
EEWORLD社区 ADI Reference Circuit
VC++ about the problem of directshow image rotating 90 degrees and outputting distorted screen
VC++ DirectShow image rotated 90 degrees output distorted screen. I rotated the image 90 degrees in transfilter and passed it to the third filter. I found that the image was distorted. The resolution ...
chunch168 Embedded System
WIFI to explore the fun of games
Now, when we talk about games, it is a hot topic. Not only young students and employees, but even employees in their 30s in the company often discuss the level issue, which shows its popularity. Games...
zxy123okok RF/Wirelessly
[Raspberry Pi 4B Review] + TCP Server and HTTP Communication
Today, I will use Raspberry Pi to build a TCP server and use HTTP communication. Without further ado, let's get started. First check whether the curl library is installed on the Raspberry Pi; Enter th...
29447945 Special Edition for Assessment Centres
What do the codes in C.bat and cebasecesysgen.bat mean?
The following is the code in C.BAT: @REM @REM Copyright (c)Samsung Elec. co, LTD. All rights reserved. @REM @echo off echo ---------------- ------------------------------- echo %_TARGETPLATROOT%\targe...
zcbing Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2357  2910  156  216  2218  48  59  4  5  45 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号