EEWORLDEEWORLDEEWORLD

Part Number

Search

2020-23T-C8F

Description
Surge Protection Circuit, PACKAGE-3
CategoryWireless rf/communication    Telecom circuit   
File Size343KB,3 Pages
ManufacturerBourns
Websitehttp://www.bourns.com
Download Datasheet Parametric View All

2020-23T-C8F Overview

Surge Protection Circuit, PACKAGE-3

2020-23T-C8F Parametric

Parameter NameAttribute value
Parts packaging codeMODULE
package instruction,
Contacts3
Reach Compliance Codeunknow
JESD-30 codeX-XXSS-X3
Number of functions1
Number of terminals3
Maximum operating temperature90 °C
Minimum operating temperature-40 °C
Package body materialUNSPECIFIED
Package shapeUNSPECIFIED
Package formSPECIAL SHAPE
surface mountNO
Telecom integrated circuit typesSURGE PROTECTION CIRCUIT
Temperature levelINDUSTRIAL
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Base Number Matches1
*R
oH
VE S CO
AV R M
AI SIO PL
LA N IA
BL S NT
E
Features
Fast acting
Balanced
Stable breakdown throughout life
Designed to operate with TBU devices
®
Applications
Telecommunications
Industrial electronics
Avionics
RoHS compliant* versions available
2020 T Series - 3-Pole Fast Gas Discharge Tube
Characteristics
Model No.
2020-15T
2020-23T
2020-42T
Characteristic
Minimum DC Sparkover
(100 V/s)
Throughout Service Life
60 V
500 V
180 V
650 V
360 V
850 V
Maximum Impulse Sparkover (5k V 1.2/50 µs)
Throughout Service Life
Impulse Transverse Delay...................1000 V/µs ............................................................................... < 75 ns
Insulation Resistance (IR) ...................50 V / 100 V ............................................................................ > 10
9
Ω
Glow Voltage ......................................10 mA ..................................................................................... ~ 70 V
Arc Voltage .........................................>1 A ........................................................................................ ~ 10 V
Glow-Arc Transition Current ............................................................................................................... < 0.5 A
Capacitance .......................................1 MHz ..................................................................................... < 1 pF
DC Holdover Voltage (Network Applied per ITU-T K.12)
2020-15T .......................................52 V ........................................................................................ < 150 ms
2020-23T .......................................80 V ........................................................................................ < 150 ms
2020-42T .......................................135 V ...................................................................................... < 150 ms
Service Life
1
.......................................8/20 µs, 5 kA .......................................................................... 1 operation
10/1000 µs, 1 kV, 100 A.......................................................... 100 operations
2
2/10 µs, 5 kV, 1000 A.............................................................. 10 operations
2
10/700 µs, 6 kV, 150 A............................................................ 50 operations
2
8/20 µs, 500 A, 1.2/50 µs, 500 V ............................................ 150 operations
2
600 V, 5 Arms, 0.2 sec. ........................................................... 10 operations
600 Vrms, 0.5 A - 60 A ........................................................... Fail-Short activates
3
230 Vrms, 0.5 A-25 A ............................................................. Fail-Short activates
3
Operating and Storage Temperature .................................................................................................. -40 to +90 °C
Climatic Category (IEC 60068-1) ....................................................................................................... 40 / 90 / 21
Notes:
1 Applied per conductor to center pin.
2 Surge polarity should be reversed between consecutive surges (+,-,+,-)
3 Applies only to GDT with optional Fail-Short. GDT operates and will survive with Fail-Short activation.
• At delivery AQL 0.65 Level II, DIN ISO 2859.
Applications
Port Protection
CanBus
RS232
RS422
RS485
RS485
SDI
VDSL
GDT Device P/N
2020-23T
2020-23T
2020-23T
2020-23T
2020-42T
2020-23T
2020-15T
TBU
®
Device P/N
TBU-CA065-100-WH
TBU-CA065-200-WH
TBU-CA065-200-WH
TBU-CA065-200-WH
TBU-CA085-200-WH
TBU-CA065-100-WH
TBU-CA050-500-WH
“TBU” is a registered trademark of Bourns, Inc. in the U.S., Taiwan and European Community.
*RoHS Directive 2002/95/EC Jan 27, 2003 including Annex.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
DSP system design - clock and power supply related issues
Q: What aspects should be paid special attention to in the power supply design and clock design of DSP? Is it better to use active or passive external crystal oscillator?A: The clock generally uses cr...
火辣西米秀 DSP and ARM Processors
【NXP USB Type C Review】 + LPC11U35 Program Development
The May Day holiday is over, and I am back to update a post. I have previously introduced and used some basic NXP USB Type-C boards. During the evaluation process, I have a certain understanding of th...
wufeijian Integrated technical exchanges
Are the salaries for test development positions higher than those for development?
1. There is a large demand for emerging positions, but talent training in all aspects is in short supply; 2. Enterprises are in urgent need of product quality, which is the key to their market positio...
led2015 Talking
Electronic circuit drawing software dxp2004 tutorial
Electronic circuit drawing software dxp2004 tutorial...
szjhtx PCB Design
About the problem of modelsim simulation clock signal
When doing simulation, the clock signal in the waveform diagram is always low. I used the same method to program the clock signal in the previous simulation and there was no problem. always#50 clk=!cl...
x1022as FPGA/CPLD
A brief discussion on PLC application fields
Over the years, programmable controllers (hereinafter referred to as PLCs) have made the leap from wiring logic to storage logic since their creation; their functions have grown from weak to strong, f...
eeleader Robotics Development

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2449  2442  2166  17  553  50  44  1  12  19 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号