EEWORLDEEWORLDEEWORLD

Part Number

Search

62-21226-33-03501

Description
Cable Assembly
CategoryThe connector    Connector bracket   
File Size566KB,1 Pages
ManufacturerGould Fiber Optics
Download Datasheet Parametric View All

62-21226-33-03501 Overview

Cable Assembly

62-21226-33-03501 Parametric

Parameter NameAttribute value
Objectid1977159414
Reach Compliance Codeunknown
applicationTELECOM; INSTRUMENTATION; MEDICAL
CertificationUL
ConnectorSide1FC/UPC
ConnectorSide2FC/UPC
Connector bracket typeCABLE ASSEMBLY
Maximum operating temperature70 °C
Minimum operating temperature-20 °C
shieldNO
PATCH CORDS
Gould optical cable assemblies feature quality parts and guaranteed performance specifications.
•Length tolerance is ±10% (minimum tolerance is ±5cm)
•Specifications are per mated pair at both 1310nm and 1550nm
Connector Insertion/Return Loss
Specifications for SMF-28 Fiber
End
Number
2
3
4
5
6
7
Connector
Insertion
Loss (dB)
≤ 0.5
≤ 0.25
≤ 0.25
< 0.25
≤ 0.25
≤ 0.25
Typical
Return
Loss (dB)
> 40
> 50
> 50
> 40
> 60
> 60
Features
Low Optical Loss
Low Polarization
Dependent Loss
Applications
Telecom
Instrumentation
Medical
ST
FC
SC
LC
FC/APC
SC/APC
PATCH CORDS
Product #:
6
-
-
Connector
End A
2
3
4
5
6
7
ST/UPC
FC/UPC
SC/UPC
LC/UPC
FC/APC
SC/APC
0
2
3
4
5
6
7
-
Connector
End B
Pigtail
assembly
ST/UPC
FC/UPC
SC/UPC
LC/UPC
FC/APC
SC/APC
Buffer Type
Length in
meters xxxx
0300
0350
3m
3.5m
etc
1
Patchcord Type
2
4
singlemode
multimode
Testing Requirements
0
1
2
3
insertion loss testing data only
insertion loss and return loss testing data
insertion loss and endface geometry data
insertion loss, return loss and endface
geometry data
Fiber Type
03
06
11
12
22
23
25
27
32
54
Corning SMF-28
TM
, 100kpsi proof test on fiber
Corning Flexcore (5/125)
50/125 Graded Index (Corning)
62.5/125 Graded Index (Corning)
200/230/500, 0.37NA SI MM HCS (Lucent)
200/230/500, 0.48NA SI MM HCS (Lucent)
100/140/250 Step Index (Lucent)
Corning Flecore (7/125)
Corning SMF-28
TM
, 200 kspi proof test on fiber
Corning Flecore (7/125), 200 kspi proof test on fiber
10
21
22
23
24
25
26
27
28
29
31
32
33
34
No buffering ( not recommended)
900 micron, white, hytrel (temp rating -20 to +70
o
C, UL 94V-HM rated)
900 micron, orange, hytrel (temp rating -20 to +70
o
C, UL 94V-HM rated)
900 micron, blue, hytrel (temp rating -20 to +70
o
C, UL 94V-HM rated)
900 micron, red, hytrel (temp rating -20 to +70
o
C, UL 94V-HM rated)
900 micron, green, hytrel (temp rating -20 to +70
o
C, UL 94V-HM rated)
900 micron, black, hytrel (temp rating -20 to +70
o
C, UL 94V-HM rated)
900 micron, brown, hytrel (temp rating -20 to +70
o
C, UL 94V-HM rated)
900 micron, gray/slate, hytrel (temp rating -20 to +70
o
C, UL 94V-HM rated)
900 micron, yellow, hytrel (temp rating -20 to +70
o
C, UL 94V-HM rated)
2.9mm x 0.4mm, Kevlar reinforced tubing, yellow
2.9mm x 0.4mm, Kevlar reinforced tubing, orange
2.9mm x 0.9mm, Kevlar reinforced tubing, orange
2.9mm x 0.45mm, Kevlar reinforced tubing, black
Specifications are based on non-connectorized products. For connectorized specifications, please call
sales for details. Custom optical & mechanical configurations are available upon request.
46
Call Toll Free: 1-800-544-6853 • FAX: 410-987-1201 • E-mail: info@gouldfo.com
CC2530 zigbee module, wireless sensor network
1.Features of SZ2 modulelTransmittingpower 20dBm ; receiving sensitivity -104dBm (BER=10-2) lOpenfrequency band, no need to apply for frequency, carrier frequency is 2.4GHz . lHighanti-interference ab...
csswxl RF/Wirelessly
Aren't all charging stations AC-DC, used to charge electric vehicles? Why are there DC charging stations?
Aren't all charging piles AC-DC, and then charge electric vehicles? Why are there DC charging piles? -----------A DC charging pile is a charging pile where the battery pack charges the battery pack of...
QWE4562009 Energy Infrastructure?
【Infineon XENSIV PAS CO2 Sensor】 Comprehensive understanding of the sensor
Product IntroductionInfineon Technologies has used its state-of-the-art capabilities in sensors and MEMS to develop an innovative carbon dioxide (CO2) sensor. By leveraging photoacoustic spectroscopy ...
秦天qintian0303 Sensor
(2) LCD display module LM6059 driver
[i=s]This post was last edited by lbbook on 2022-3-1 00:49[/i]1. Introduction to LCD display module LM6059BCW Graphic Display Module The main parameters are as follows Resolution: 128 x 64 Interface: ...
lbbook GD32 MCU
The boiler feed water pump starts and stops frequently, with only acceleration time and zero deceleration time?
In a boiler room today, a frequency converter switch is used to control the frequent start and stop of the water supply pump, but there is only an acceleration time control process, and no deceleratio...
eeleader-mcu Industrial Control Electronics
VS2008+ce6.0 doesn't seem to run.
I have tried this combination many times but it didn't install successfully. Is it possible that 6.0 doesn't support 2008? Do I have to go back to 2005?...
ghjkl Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1098  1674  2820  2756  475  23  34  57  56  10 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号