EEWORLDEEWORLDEEWORLD

Part Number

Search

CCM250PS28

Description
250 W Convection Cooled
File Size589KB,2 Pages
ManufacturerXP Power
Websitehttps://www.xppower.com/
Download Datasheet Compare View All

CCM250PS28 Online Shopping

Suppliers Part Number Price MOQ In stock  
CCM250PS28 - - View Buy Now

CCM250PS28 Overview

250 W Convection Cooled

AC-DC
250 Watts
CCM Series
250 W Convection Cooled
300 W Peak Rating for 500 ms
Very High Efficiency up to 95%
xppower.com
Class B Conducted & Radiated Emissions
80 - 275 VAC Operation
IT, Industrial & Medical Safety Approvals
3 Year Warranty
Specification
Input
• 80-275 VAC (See derating curve)
• 47-63 Hz
• 2.4 A typical at 115 VAC, full load
1.2 A typical at 230 VAC, full load
Inrush
Current
• 30 A max at 230 VAC, cold start at 25 °C
Power Factor
• >0.9
Earth Leakage Current
• 250 µA max at 264 VAC/60 Hz
Input Protection
• Internal T5.0 A/250 V fuse in line
and neutral
Input Voltage
Input Frequency
Input Current
General
Efficiency
Isolation
Switching Frequency
Signals
MTBF
• Up to 95%
• 4000 VAC Input to Output, 1500 VAC Input
to Ground, 500 VAC Output to Ground
• PFC 30-500 kHz, Boost 25.6 kHz,
Main 51.2 kHz
• Power Fail - open collector, transistor off for
AC good, ≥5 ms warning of loss of output
• 365 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature
• -20 ˚C to +70 ˚C derate linearly from +50 °C
at 2.5%/°C to 50% load at +70 °C.
See derating curve and longform datasheet
for thermal considerations. (-40 °C consult
sales)
Cooling
• Convection cooled
Operating Humidity
• 95% RH, non-condensing
Storage Temperature
• -40 °C to +85 °C
Operating Altitude
• 3000 m
Shock
• 30 g pk, half sine, 6 axes
Vibration
• 2 g rms, 5 Hz to 500 Hz, 3 axes
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Drift
Line Regulation
Load Regulation
Over/Undershoot
Transient Response
12-48 VDC (see tables)
±3% (see Mechanical Details)
±0.5% V1, ±5% V2
No minimum load required
1 s typical
50 ms typical
16 ms min at 115 VAC
±0.2% after 20 min warm up
±0.5% max
±1% V1, ±5% V2
5% typical
4% max. deviation, recovery to within
1% in 500 µs for a 50-75-50% load
change
1% pk-pk, 20 MHz bandwidth
115-140% Vnom, recycle input to reset (V1
only)
125-165% Inom V1 only
Continuous trip and restart (hiccup mode)
0.05%°C
EMC & Safety
Low Voltage PSU EMC
• EN61204-3, high severity level
Emissions
• EN55011/32 level B conducted
EN55011/32 level B radiated
RTCA D0160D 21.4 Cat. M radiated
MIL-STD 461D-F, CE102
Harmonic Currents
• EN61000-3-2, class A,
EN61000-3-2, class C for loads ≥40%
Voltage Flicker
• EN61000-3-3
Radiated Immunity
• EN61000-4-3, level 3 Perf Criteria A
EFT/Burst
• EN61000-4-4, level 3 Perf Criteria A
Surge
• EN61000-4-5, installation class 3
Perf Criteria A
Conducted Immunity
• EN61000-4-6, level 3 Perf Criteria A,
MIL-STD 461 CS114
Dips & Interruptions
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B,
EN60601-1-2, 30% 500 ms, 60% 100 ms,
100% 10 ms, 100% 5000 ms, Perf Criteria
A, A, A, B - 230 VAC. Consult longform
datasheet for 115 V operation.
Safety Approvals
• See Safety Approvals (see next page)
Equipment Protection
• Class I
Class
Ripple & Noise
Overvoltage Protection
Overload Protection
Short Circuit Protection
Temperature
Coefficient
Remote On/Off
(Inhibit/Enable)
• Uncommitted isolated optocoupler diode,
powered diode inhibits V1

CCM250PS28 Related Products

CCM250PS28 CCM250PS12 CCM250PS15 CCM250PS24 CCM250PS36 CCM250PS48 CCM
Description 250 W Convection Cooled 250 W Convection Cooled 250 W Convection Cooled 250 W Convection Cooled 250 W Convection Cooled 250 W Convection Cooled 300 W Peak Rating for 500 ms

Recommended Resources

How to extract the output of the computer sound card using a microcontroller?
As the title says. I want to make an alarm circuit and use the output of the computer sound card to drive the alarm bell. Is there such an ADC chip? Are there other good circuits or methods?...
森林898 Embedded System
DMA Test
I am new to 67XX series chips and need to use DMA transmission. Can experts provide a DMA code for me to learn? Thank you! [email]jyjun9876@126.com[/email]...
jyjun9876 DSP and ARM Processors
Wince hot start problem
I used KernelIoControl(IOCTL_HAL_REBOOT, NULL, 0, NULL, 0, NULL) to restart wince. This should be a warm boot, so the changes I just made to the system should be retained in RAM. But why are all the c...
applebee Embedded System
STM32MP157A-DK1 Review
Activity link: Try STM32MP157A for free, come and play if you want!STMicroelectronics STM32MP157A-DK1 Discovery KitThe STMicroelectronics STM32MP157A-DK1 Discovery Kit enables easy application develop...
okhxyyo Special Edition for Assessment Centres
TouchGFX Design + Make a Rubik's Cube (3)
[i=s] This post was last edited by tobot on 2019-4-13 00:59 [/i] [align=left]Use TouchGFX to make a Rubik's Cube (Day 3) [/align][align=left]Today I completed the code for the 3d cube. [/font][/align]...
tobot stm32/stm8
【KW41z】FREEDOM KW41Z circuit diagram
Today I finally have time to play with this board I've always wanted to play with:loveliness: I just searched and didn't find anyone who uploaded this circuit diagram. I'm very interested in first-han...
dontium NXP MCU

Popular Articles

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1228  1910  88  2766  1139  25  39  2  56  23 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号